A very simple low battery cut-off and overload protection circuit has been explained here.

Table of Contents
  • How it Works
    • Parts List
  • Formulas and Calculations
  • Inverter Overload Cut-OFF using Opamp
    • How it Works
    • Formulas and Calculations

The figure shows a very simple circuit set up which performs the function of an overload sensor and also as an under voltage detector.

In both the cases the circuit trips the relay for protecting the output under the above conditions.

How it Works

Transistor T1 is wired as a current sensor, where the resistor R1 forms the current to voltage converter.

The battery voltage has to pass through R1 before reaching the load at the output and therefore the current passing through it is proportionately transformed into voltage across it.

This voltage when crosses the 0.6V mark, triggers T1 into conduction.

The conduction of T1 grounds the base of T2 which gets immediately switched Off. The relay is also consequently switched OFF and so is the load.

T1 thus takes care of the over load and short circuit conditions.

Transistor T2 has been introduced for responding to T1's actions and also for detecting low voltage conditions.

When the battery voltage falls beyond a certain low voltage threshold, the base current of T2 becomes sufficiently low such that it's no longer able to hold the relay into conduction and switches it OFF and also the load.

Low Battery and Overload Protection Circuit for Inverters

The"LOAD" terminals in the above diagram is supposed to be connected with the inverter +/- supply terminals.

This implies that the battery current from the right side has to pass through R1 before reaching the inverter, enabling the sensing circuit around R1 to sense a possible over current or overload situation.

CORRECTION:

The above shown circuit will not initiate unless the relay is actuated manually through a push switch as shown below:

Low Battery and Overload Protection Circuit for Inverters with push button start

Parts List

  • R1 = 0.6/Trip Current
  • R2 = 100 Ohms,
  • R3 =10k
  • R4 = 100K,
  • P1 = 10K PRESET
  • C1 = 100uF/25V
  • T1, T2 = BC547,
  • Diodes = 1N4148
  • Relay = As per the specs of the requirement.

Formulas and Calculations

Low Battery Cut-off Threshold

The low battery sensing is handled by R3 and P1 which forms a potential divider to set the base voltage of the relay driver transistor (T2). When the battery voltage drops below a set threshold the voltage at the base of T2 falls below Vbe (0.6V–0.7V) turning OFF the relay and disconnecting the load.

Formula for Threshold Voltage:

Vth = Vbat * (P1 / (P1 + R3))

  • Where:
  • Vth = Base threshold voltage (0.6V–0.7V)
  • Vbat = Battery voltage
  • P1 = Adjustable potentiometer resistance
  • R3 = Fixed resistor

To calculate the battery voltage cut-off level:

Rearrange for Vbat:

Vbat = Vth * (P1 + R3) / P1

Overload/Overcurrent Sensing

Overcurrent protection is implemented using R1 which is placed between the base and emitter of transistor T1.

As the load current increases, the voltage drop across R1 rises. When the voltage across R1 reaches the Vbe of T1 (typically 0.6V–0.7V) T1 starts conducting and shunts the base current of T2 turning it OFF.

Formula for Overcurrent Trip Current:

Itrip = Vbe / R1

  • Where:
  • Itrip = Overcurrent trip current
  • Vbe = Base-emitter threshold voltage of T1 (0.6V–0.7V)
  • R1 = Resistor sensing the overcurrent

Base Current Limiting Resistor (R2)

Resistor R2 (optional) limits the base current for T1 to prevent excessive current through its base-emitter junction.

Formula for Base Resistor (if used):

R2 = (Vbat - Vbe) / Ib

  • Where:
  • Ib = Required base current for T1
  • Vbat = Battery voltage
  • Vbe = Base-emitter voltage of T1

For small signal transistors (e.g., BC547) Ib can be estimated as Iload / hFE where hFE is the DC current gain.

Inverter Overload Cut-OFF using Opamp

In the above paragraphs I have explained a very simple concept of inverter overload cut-off using only transistors.

However a cut off system using only transistors cannot be very accurate and sharp.

In order to get a precision inverter overload and short circuit cut off circuit the use of an opamp based design becomes imperative.

The following diagram shows a simple battery overload controller circuit using a single opamp 741 and a relay driver stage.

Inverter Overload Cut-OFF circuit

How it Works

The opamp is configured as a simple comparator circuit. he inverting input of the opamp is clamped at a fixed 0.6 V using a 1N4148 diode.

The non-inverting input of the op amp is connected with the negative line of the circuit through a over-current sensor resistor Rx.

Due to inverter overload or short circuit or over current conditions, a voltage drop develops across the resistor Rx which can exceed the 0.6V as per the calculated value of the RX, and cause the non-inverting input of the opamp potential to go higher then its inverter 0.6V potential.

This causes the op amp output to turn high activating the transistors and tripping the relay.

When power is first switched ON, and assuming the inverter is working normally without an overload, the voltage developed across RX is minimal, which keeps the pin3 potential of the opamp the opamp lower than the pin2 potential.

This allows the output of the opamp to be low ensuring that the transistor is switched OFF, and relay contacts stays at the N/C point.

Due to this the 12V is able to reach the inverter and operate it normally.

However, as soon as an overload or over current happens at the inverter side, a large amount of current passes through the RX resistor, causing a voltage drop to develop across pin3 of the IC.

When this voltage drop exceeds the 0.6V reference level of the pin2 of the IC, the output of the op amp goes high, causing the transistor to switch ON and trigger the relay.

The relay contacts now shift from N/C to N/O switching of power to the inverter and thereby averting the short circuit or overload conditions.

The N/O contact can be seen attached with the base of the relay driver transistor, which ensures that as soon as the an overload is detected the relay contact quickly latches the transistor, switching the power permanently off for the inverter.

The power can be restored only by disconnecting the 12 V battery input, but before that it must be ensured that the short circuit or the over load condition is appropriately removed from the inverter side.

Formulas and Calculations

Key Parameters

  • RX: Current sensing resistor (ohms)
  • Vref: Reference voltage at the inverting input (-) of IC741
  • Itrip: Overcurrent trip current (amperes)
  • Vdrop: Voltage drop across RX at trip current

Formulas

Voltage Drop Across RX:

Vdrop = Itrip * RX

  • Where:
  • Itrip = Overcurrent trip point (A)
  • RX = Current sensing resistor (ohms)

Reference Voltage (Vref):

The voltage at the non-inverting input (+) of IC741 is set using a resistor divider or Zener diode (if used). For proper cutoff:

Vref ≈ Vdrop

Choosing RX (Sensing Resistor):

To calculate the value of RX for a given trip current:

RX = Vref / Itrip

  • Where:
  • Vref = Reference voltage (V)
  • Itrip = Desired trip current (A)

Power Dissipation in RX:

The sensing resistor RX must handle the power dissipated during operation.

We will Use:

P = Itrip2 * RX

  • Where:
  • P = Power dissipation in RX (W)

Choose RX with a power rating higher than P for safe operation.

Example Calculation

Let’s assume:

Itrip = 10A (trip current)

Vref = 0.7V (reference voltage determined by the op-amp threshold)

Step 1: Calculate RX

RX = Vref / Itrip = 0.7 / 10 = 0.07 ohms

Step 2: Power Dissipation in RX

P = Itrip2 * RX = 102 * 0.07 = 7W

Choose a 0.07-ohm 10W resistor for RX to ensure safe operation.

You'll also like:

  • SPDTtriac 1SPDT Relay Switch Circuit using Triac
  • Grid Tie Inverter2C Wiring Details2C DiagramHow to Calculate Solar Panel, Inverter, Battery Parameters
  • inverter circuit with feedback control compressedInverter Circuit with Feedback Control
  • driverArduino 3 Phase Inverter Circuit with Code

Filed Under: Inverter Circuits Tagged With: Battery, Inverters, Overload, Protection

About Swagatam

I am an electronics engineer and doing practical hands-on work from more than 15 years now. Building real circuits, testing them and also making PCB layouts by myself. I really love doing all these things like inventing something new, designing electronics and also helping other people like hobby guys who want to make their own cool circuits at home.

And that is the main reason why I started this website homemade-circuits.com, to share different types of circuit ideas..

If you are having any kind of doubt or question related to circuits then just write down your question in the comment box below, I am like always checking, so I guarantee I will reply you for sure!



Previous Post: « Make This 1KVA (1000 watts) Pure Sine Wave Inverter Circuit
Next Post: Cheapest SMPS Circuit Using MJE13005 »

Reader Interactions

Questions & Answers

Total Posts: 254 (Older Threads Archive)
Newest Oldest
SwagatamAdmin
August 13, 2013 • 13 years ago #14318

No this circuit cannot be used in any manner for feeding a 3525 input, because the IC requires definite logic level which cannot be achieved from a transistor, you will have to incorporate a 741 IC for it.

Reply
Allnight
August 19, 2013 • 13 years ago #14459

New question about this: Could two of these circuits be hooked up to the same relay?

I have an RV with two sets of batteries: house and chassis. When the engine is running (the chassis battery is over 13V), I want to connect the two sets of batteries. When the house is plugged in (house battery over 13V), connect the two sets of batteries.

Also, if the voltage of either side goes over 16V, disconnect them (that part may be harder, and not an original requirement, it just occurred to me).

I was hoping to build two of these circuits, one hooked up to the chassis battery and the other hooked up to the house battery, and have a single relay connect the two batteries. I want to limit the current that crosses the relay to about 30amps (the max output of the house battery charger, as the engine alternator can put out 190amps).

I'm currently hunting for a relay that will strongly move to open when the coil isn't energized, as I don't want bumps in the road to accidentally flip the relay to the connected state.

Reply
SwagatamAdmin
August 19, 2013 • 13 years ago #14472

Yes that would be possible, you just have to make the collectors of T2 common from the two circuits, and join with the relay coil.

For 30 amps you would need a powerful relay which would obviously have a tough electromagnetic connection, so hopefully it won't be rattled by the "bumps"

T2s will need to be appropriately dimensioned as per the relay coil ratings.

Reply
tervkal
September 2, 2013 • 13 years ago #14861

Hi, thank you for your great cutoff circuit. I suppose the cutoff voltage is changing by temperature quite large range in your circuit. A base-emitter voltage of the bipolar transistor has a temperature coefficient at least -2mV/C. That is not a problem because a battery to be charged only in specified temperature range.

Reply
SwagatamAdmin
September 3, 2013 • 13 years ago #14878

you are right, thanks!

Reply
SwagatamAdmin
September 10, 2013 • 13 years ago #15096

Make R3 = 22k, and R2 = 1k, that's all, other components will remain as is except the relay which should be 24V rated.

Reply
Walkabout
November 26, 2013 • 13 years ago #17540

I easily get confused, after I drew the schematic diagram. My questions are;
1st:There are 3 connections for R3 preset, the 3rd will not be connected, right?
2nd: Where will the negative polarity of the battery be connected?
3rd: T2 base is connected to the 1K, while the other two terminals go to the positive and the ground respectively. Is the emitter the ground?

Could help me redraw the schematic?

And for just overload cut-off circuit, what would I need in a circuit and what would the schematic look like?

Reply
SwagatamAdmin
November 27, 2013 • 13 years ago #17552

1) In the above updated diagram R3 is a fixed resistor P1 is the preset, yes, any two terminals of the preset can be selected, the center lead being the mandatory one.
2)the line which joins R1, T1 emiter, C1 negative and D1 cathode is the negative line.
3) please refer to the above diagram, I am not sure which diagram you are referring to?

Reply
Walkabout
November 29, 2013 • 13 years ago #17644

Continuing the discussion of just having low voltage cutoff circuit. You mention(I'm quoting you) "Keep only D1, D2, T2 and the relay, eliminate everything else.

However R3 now gets replaced by a preset, the center goes to the base of T2, the other two terminals go to the positive and the ground respectively.

For safety add a 1K resistor with the base of T2 which then can be connected to the center tag of the preset."

ok following your instructions and basing from the updated diagram, lead me to redraw it to fit for a low voltage cutoff circuit imageshack.com/a/img443/5532/6s0f.png.

is that the schematic for a adjustable low voltage cutoff circuit?

Reply
Andrew
May 8, 2019 • 7 years ago #66911

Hello sir, I understand everything else about this circuit except for (R1) please i do not know what am suppose to use, if it,s resistor, fuse or breaker as (0.6/Trip Current) because what i understand is that the negative taminal of the better is suppose go to the inverter negative source which means using a resistor is not going to be a good idea, please i need your help because i have already finished building this circuit with a (0.22 ohm) resistor in place of (R1) but i need to know exactly am suppose to use before testing it because am sure. Thanks

Reply
SwagatamAdmin
May 8, 2019 • 7 years ago #66913

R1 is a resistor, its wattage should be = 0.6 x maximum trip current value.
You are supposed to do exactly what is shown in the diagram, the negatives have to connect through the resistor R1.

Here’s another similar design you can try which is thoroughly tested by me:

https://www.homemade-circuits.com/how-to-make-automotive-electronic-fuse/

Reply
Andrew
May 8, 2019 • 7 years ago #66917

OK, thanks 4 ur quick respond, i really do appreciate.

Reply
SwagatamAdmin
November 29, 2013 • 13 years ago #17655

the image link is not opening in my computer.
It should be OK if you have done as per the mentioned instructions.

Reply
Walkabout
November 29, 2013 • 13 years ago #17658

Now i tried google drive, if you can view the image. https://drive.google.com/file/d/0BytEbOgq6mqeQU5mdzU4Yl9kUDA/edit?usp=sharing

Reply
SwagatamAdmin
November 30, 2013 • 13 years ago #17681

R3 preset bottom free end should be connected to the negative line.

the indicated +/- lines are correct. The relay out is positive, the bottom rail is the negative.

Reply
Debashees Sikder
January 17, 2014 • 13 years ago #19086

Sir,
Can I use this circuit with sg3525 without relay?I am thinking that I can use a PNP transistor , am I right?

Reply
SwagatamAdmin
January 18, 2014 • 13 years ago #19103

The above circuit is suitable only with a relay, for 3524 IC only an opamp circuit would be suitable

Reply
Muhammad Junaid
February 19, 2014 • 12 years ago #19979

Hello Sir I want to make an overload protection circuit which can sustain upto 600Watts or as per requirement by use of Potentiometer. Please help me out how to modify this circuit for this purpose..

Reply
SwagatamAdmin
February 20, 2014 • 12 years ago #19995

Hello Muhammad, you can do it by replacing R2 with a 1k pot. the ends of the pot will go to transistor base and R1, while the center will touch the ground

Reply
Oluwaseyi Onasami
March 26, 2014 • 12 years ago #20847

Hello Swagatam,

I have tried working with the Overload, Short Circuit and Load Battery Cut-Off Circuit but having challenges setting the cut-off voltage (10.5V) and getting the right value for R1. I want to use it for 2KVA inverter.

Secondly, can you help with a 12V, 100AH charger circuit with constant current charging and overcharge protection at 13.5V.

Thanks in this regard.

Reply
SwagatamAdmin
March 27, 2014 • 12 years ago #20871

Hello Oluwaseyi,

if you are using a battery then the settings should be easier to implement, if the input is through a power supply then it would need to be regulated.

If you find it difficult then it could go for an IC based design.

You can try the last charger circuit for your 100 ah battery from the following link, just replace the shown LM338 with LM396 or LM196

https://www.homemade-circuits.com/2012/07/making-simple-smart-automatic-battery.html

Reply
Michael Ihekwereme
June 13, 2021 • 5 years ago #90933

can you share your overload design circuit

Reply
Rolando Avecilla
April 1, 2014 • 12 years ago #21041

Thanks for this circuit.

How can I modify this to use solid state relay?

Reply
SwagatamAdmin
April 2, 2014 • 12 years ago #21059

It may be done wit the following mods:

Remove the relay and R4 entirely.

replace the relay coil connection points with the battery poles.

T2 may be upgraded as per the load amp specs.

Reply
Lester Johnson
April 16, 2014 • 12 years ago #21492

Sir . Will you low battery cut off circuit, turn on the inverter when the battery is recharge?

Reply
SwagatamAdmin
April 16, 2014 • 12 years ago #21508

it may be done by incorporating another relay parallel to the existing one and by wiring its contacts appropriately for the intended chageover

Reply
Shankar ks
May 5, 2014 • 12 years ago #22137

sir i need circuit for cutoff voltage with 2millivolt.

Reply
SwagatamAdmin
May 6, 2014 • 12 years ago #22182

use any of the following circuits, replace 741 with LM311

https://www.homemade-circuits.com/2011/12/how-to-make-simple-low-battery-voltage.html

Reply
Shankar ks
May 26, 2014 • 12 years ago #22879

will that circuit need any other changes for cutoff voltage as 2 millivolt.

Reply
SwagatamAdmin
May 27, 2014 • 12 years ago #22891

no changes would be required…it will respond even to the minutest changes between its inputs.

Reply
sskopparthy
May 8, 2014 • 12 years ago #22242

sir, you told that "https://drive.google.com/file/d/0BytEbOgq6mqeQU5mdzU4Yl9kUDA/edit?usp=sharing" is the circuit low battery cut off(to walkabout in above comments). i would like you to help me to modify this circuit to suit my needs. i am not a genius and just a beginner. so, i dont know whether my idea is correct and it can be done or not. i wanted to tell that when load is applied to circuit, and when its voltage decreases to preset level, it cuts off the relay. but when load is disconnected, i observed that the battery regains its voltage to some extent. so, then the circuit may connect the load again……so, i request you to modify this circuit such that, once it cuts the load, it should stay in cutoff position only until a reset button is pressed….can this be done to this circuit, sir? im just a beginner, so please help me ………

Reply
SwagatamAdmin
May 8, 2014 • 12 years ago #22255

ss, there are two faults in the shown link, first the N/C should not be connected to ground, second, R3 other end must be connected to ground, rest everything looks OK.

it's highly unlikely that the relay would oscillate, due to the presence of the transistor hysteresis, so probably no latching feature would be required.

Reply
sskopparthy
May 9, 2014 • 12 years ago #22278

Sir, I connected the circuit in the correct way only as you said……before making this comment. But I failed to check the circuit diagram before giving the link(I erased n/c and connected r3 other end to ground but didn't save it but I thought I did). And thank you very much sir…now the circuit seems to be good working…..

Reply
SwagatamAdmin
May 10, 2014 • 12 years ago #22295

OK, no problem, that's great!

Reply
Shahirah MNY
May 13, 2014 • 12 years ago #22402

hello sir, can this kind of cct can be modified to trip low standby current? thank you 🙂

Reply
SwagatamAdmin
May 13, 2014 • 12 years ago #22426

hello shahirah,yes it can be done by setting the preset appropriately.

Reply
adelusi oluwatosin
July 27, 2014 • 12 years ago #24607

Thanks for time spending on this site. Sir can this circuit work for 3kva inverter? If yes kindly do the adjustment more so I need to know total calculation of R1. Thanks.

Reply
SwagatamAdmin
July 27, 2014 • 12 years ago #24619

Yes it will work with 3kva inverter, just modify the relay contact accordingly and use 8050 for T2.

Reply
Vishnu Menon
August 4, 2014 • 12 years ago #24795

Sir ,
I didn't understand the preset part correctly can u explain its working in the given circuit

Reply
SwagatamAdmin
August 5, 2014 • 12 years ago #24812

Vishnu. apply the lower battery cut off voltage to the circuit through an adjustable power supply and adjust P1 until the relay just deactivates, once this is setting is done the circuit would automatically switch OFF whenever the battery voltage reaches this level

Reply
Vishnu Menon
August 23, 2014 • 12 years ago #25179

How to make resistors of such low value 6miliohms etc here I am stuck do u have any idea pls let me know

Reply
SwagatamAdmin
August 23, 2014 • 12 years ago #25186

use a couple of inches long non-plated iron wire, or a meter long copper wire wound on a former, tweak and adjust the lengths by verifying the ohms through a suitable multimeter.

Reply
Mouhammad Alnajjar
September 23, 2014 • 12 years ago #25931

hello sir

if the circuit current is 1.5A and i wanna cut-off at 10.5 volts which relay I have to use ?

if the cut-off volt is changed what is the rule to choose the suitable relay?

Reply
SwagatamAdmin
September 24, 2014 • 12 years ago #25943

hello Mouhammad,

the relay has no relation to amps and cut off voltage of the design….you just have to choose a relay whose coil voltage is matching with the supply voltage of the circuit and adjust the preset such that relay just cuts off at the specified lower threshold….the adjustment will need to be made by supplying this lower threshold through an external power supply while setting up.

Reply
Mouhammad Alnajjar
September 24, 2014 • 12 years ago #25955

thanks so much sir

there is something else :
is this circuit re-activate automatically after it is deactivated ?
because if it cuts-off at (e.g 11 volts) , the voltage will be more than 11 volts with after the loading ends, so the circuit will be activated then deactivated many times

Reply
SwagatamAdmin
September 25, 2014 • 12 years ago #25985

No that won't happen because of the transistors hysteresis properties…

Reply
Mouhammad Alnajjar
September 26, 2014 • 12 years ago #26029

ok that's good

but 'm facing a problem with relay connections

this is the diagram :
imagizer.imageshack.us/v2/280x200q90/537/zaHcTY.jpg

with the meter I've found the points (2,1) in the place of (3,5) and (3,5) in the place of (2,1) I don't know how or why

because I've found connection between the points 4 with 2 not 4 with 5 !

how can treat this please ?

Reply
SwagatamAdmin
September 27, 2014 • 12 years ago #26038

If you can show me the relay image I can try to help, without seeing the relay image it would be difficult to locate.

Reply
Mouhammad Alnajjar
September 27, 2014 • 12 years ago #26056

this is a video I've recorded :
youtu.be/bi4bgS_6YEU

in the website of the store I've bought from , there is the diagram of points connections the same I told you
http://www.matni.com/Arabic/Relay/RELAY.htm

the relay model is T-73 and in the website I think it's the same JQC-3F(T-73)

Reply
SwagatamAdmin
September 28, 2014 • 12 years ago #26065

the connections for this relay have been elaborately explained in this article, please check it out:

https://www.homemade-circuits.com/2012/01/how-to-understand-and-use-relay-in.html

Reply
Mouhammad Alnajjar
September 30, 2014 • 12 years ago #26121

well , I've made the circuit and put a red led to detect the passing of the current , and R1 = 3 resistors 2watt : 2x(1 ohm) and 2.7 ohm
I've tested it with 9v and 12v battery
when I change the preset the circuit doesn't deactivate !
although I've connected each point of the relay to the true point
can you help me please ?
thanks

youtu.be/AshLT5g010M

Reply
SwagatamAdmin
October 1, 2014 • 12 years ago #26133

for setting up the low voltage cut off, you will have to connect the 9V source to the "load" marked terminals and then adjust the preset until the relay just trips, after this the source may be removed from the "load" terminals and the actual 12V battery connected to the "battery" marked terminals for normal operations

R1 has not related to the above setting. It determines the overload threshold trip point for the relay.

Reply
HuynhNguyet
October 9, 2014 • 12 years ago #26308

Hello Sir,

I assembled this circuit. However, there is not the voltage in the load with any level battery voltage (11V – 13.5V).

Reply
HuynhNguyet
October 9, 2014 • 12 years ago #26309

Hello Sir,

I assembled this circuit. However, the relay do not active when the bettery is 13V (0V in the load). When I remove T2, I connect direct from relay->diode-> mass, the relay actived (the battery is 13V, 13V in the load). I don't known why.

Reply
SwagatamAdmin
October 9, 2014 • 12 years ago #26314

hello Huynh, either your transistors are not good, or the preset is not correctly set or T1 is interfering due to some incorrect connections, pls check everything again.

Reply
HuynhNguyet
October 10, 2014 • 12 years ago #26325

Hello Sir,
Thank you very much for your reply.
I will check T1 and some connection again. When I use Proteus software to sumilate, the result is the same my assembled circuit (the relay does not active when battery is 13V).

Reply
SwagatamAdmin
October 10, 2014 • 12 years ago #26337

check the base voltage of T2 at 13V, it should be 0.6V to activate the relay…the relay will not activate if its coil resistance is very low in that case R3 will need to be reduced for triggering the relay….1K could be tried for R3

Reply
HuynhNguyet
October 13, 2014 • 12 years ago #26434

Hello sir,
Thank you very much for your support.
I already check the base voltage of T2 at 13V, it is 0.6 V. I change R3 by 1k resistor, then I set P1 (P1=10k). The relay is not active (I am sure the relay is ok)

Reply
SwagatamAdmin
October 13, 2014 • 12 years ago #26444

Hello Huyn, connect a LED with a series 1k resistor parallel with the relay coil and check the response…if the LED glows/shuts off in response to the preset adjustments would mean the relay has problems or is not correctly matched.

Reply
HuynhNguyet
October 13, 2014 • 12 years ago #26450

Hello Sir,
Thank you very much for your support.
I already connect a Led with series 1k resistor parallel with the relay coil. The Led light. That it's mean the relay has problem?

Reply
SwagatamAdmin
October 13, 2014 • 12 years ago #26458

hello Huynh, short the collector/emitter of T2 manually, if the relay clicks would indicate a good relay but a faulty transistor…

Reply
HuynhNguyet
October 14, 2014 • 12 years ago #26471

Hello Sir,
Thank you very much for your support.
When I shorted the collector/emitter of T2 manually, the relay clicked. That it's mean T1 or T2 faulty?

Reply
SwagatamAdmin
October 14, 2014 • 12 years ago #26482

OK now remove the collector of T1 from R3/P1 and check again, this time if the relay functions normally through T2 would indicate a faulty T1….otherwise it's T2 that may be doubtful..

Reply
HuynhNguyet
October 14, 2014 • 12 years ago #26485

Hello Sir,

I already remove the collector of T1 from R3/P1, the relay does not active at 13V. May be I will change T2 tomorow.
Thank you very much.

Reply
SwagatamAdmin
October 15, 2014 • 12 years ago #26500

OK!

Reply
HuynhNguyet
October 15, 2014 • 12 years ago #26517

I'm sorry sir
I can not find any error. T2, T1, relay … are ok. I don't know why.

Reply
SwagatamAdmin
October 15, 2014 • 12 years ago #26533

there's no way a relay won't activate if the transistor is good, connected rightly, base getting 0.6V and the power supply current sufficient…

remove the emitter diode and check, may be it's faulty.

Reply
HuynhNguyet
October 16, 2014 • 12 years ago #26551

Hello Sir,
I made new board with new components, the relay does not active. When I check the load voltage is 1.3V at 13V battery.
Thank you very much for your support!

Reply
SwagatamAdmin
October 16, 2014 • 12 years ago #26565

Hello Huynh, try the following basic relay driver stage first, and check the response:

https://www.homemade-circuits.com/2012/01/how-to-make-relay-driver-stage-in.html

Reply
HuynhNguyet
October 17, 2014 • 12 years ago #26577

Hello Sir,
Does R1 relate this problem?

Reply
SwagatamAdmin
October 18, 2014 • 12 years ago #26591

No, R1 has no connection with this problem.

Reply
HuynhNguyet
October 22, 2014 • 12 years ago #26687

Hello Sir,
Does N/C pin of relay connect to R4 and NO pin connect to R3?

Thank you for your support!

Reply
SwagatamAdmin
October 22, 2014 • 12 years ago #26704

hello Hunnh, yes that's correct.

Reply
HuynhNguyet
October 23, 2014 • 12 years ago #26730

Hello Sir,

If I only use low bettery cut-off function, What component's I remove?
Thank you very much.

Reply
HuynhNguyet
October 23, 2014 • 12 years ago #26736

Hello Sir,
If I choice C1 = 100uF/50V, is it ok?
Thank you for your support.

Reply
SwagatamAdmin
October 23, 2014 • 12 years ago #26750

yes C1 = 100/50 will also do.

Reply
SwagatamAdmin
October 23, 2014 • 12 years ago #26751

you can try the following design which is without overload cut off

https://www.homemade-circuits.com/2011/12/simplest-smf-automotive-battery-charger.html

Reply
HuynhNguyet
October 23, 2014 • 12 years ago #26760

Hello Sir,
My equipment use 12V battery. I want to isolate between the equipment and battery when the battery voltage is 11.5V in order to protect battery. When battery voltage is 12V, it will supply power for the equipment again.
Thank you for your help.

Reply
SwagatamAdmin
October 23, 2014 • 12 years ago #26766

Hello Huyn, a 12V batt must be charged until it reaches 14V, therefore once your battery gets discharged to 11.5V, it should be charged to 14V before using…

the above linked design will do the above mentioned operations appropriately

Reply
HuynhNguyet
October 24, 2014 • 12 years ago #26781

Hello Sir,
Where do load and battery connect?

Reply
HuynhNguyet
October 31, 2014 • 12 years ago #26859

Hello Sir
I'm sorry if my comment made you discomfort.
I change BC547 by C1815, that is ok.

Thank you very much for your design.

Reply
SwagatamAdmin
November 1, 2014 • 12 years ago #26876

OK that's great!

Reply
HuynhNguyet
November 3, 2014 • 12 years ago #26902

Hello Sir,
I don't understand: When the battery is 13V, there is not power to B pin of BC547 (T2), T2 can not active, so relay can not active.
Would you like to explain that? Thank you very much.

Reply
SwagatamAdmin
November 3, 2014 • 12 years ago #26918

hello Huyn, if you have selected 13V as the triggering threshold then you must adjust the preset until the relay gets activated at 13V…..

Reply
HuynhNguyet
November 5, 2014 • 12 years ago #26939

Hello Sir,
Intermediate relay only endure current 10A, how do we use for current 30A?
Thank you very much.

Reply
SwagatamAdmin
November 5, 2014 • 12 years ago #26952

hello Huyn, what's intermediate relay? relays are available in all shapes, sizes and ratings, 30amp are also available.

Reply
Yel Bordallo
November 24, 2014 • 12 years ago #27276

Hello sir can i used overload protection only in this circuit…what parts of this circuit i will remove…thank you hope for your quick response…

Reply
SwagatamAdmin
November 25, 2014 • 12 years ago #27286

Hello Yel, you'll have to use the entire circuit as shown even if you want only the overload to work….

Reply
Naveenkumar T N
December 14, 2014 • 12 years ago #27614

what is the maximum load it can handle

Reply
SwagatamAdmin
December 15, 2014 • 12 years ago #27627

will depend on the relay contact…..can be upgraded to any limits.

Reply
Shankar ks
April 10, 2015 • 11 years ago #29931

hi sir, can i connect load cell directly to arduino. if no, please give the interface circuit to connect load cell to arduino(supply voltage should not more than 6v)

Reply
SwagatamAdmin
April 10, 2015 • 11 years ago #29936

Hi shankar, please provide the info in more detail regarding the application so that I can understand and design it better.

Reply
SwagatamAdmin
April 15, 2015 • 11 years ago #30051

…ok got it, you meant to say the lower cut off voltage, yes that's right, 18V is correct.

Reply
SwagatamAdmin
April 26, 2015 • 11 years ago #30382

10k ohms is the right value

Reply
SwagatamAdmin
April 27, 2015 • 11 years ago #30424

yes that's correct

Reply
SwagatamAdmin
April 27, 2015 • 11 years ago #30425

R4 is for making sure that the relay gets latched after activation when any of the situation is detected…C1 is for preventing the relay from chattering during the operating thresholds.

Reply
Ben
July 30, 2015 • 11 years ago #32774

How is the protection circuit connected to the inverter circuit?

Reply
SwagatamAdmin
July 31, 2015 • 11 years ago #32792

the "LOAD" is the inverter supply input….

Reply
Sina Alimorady
October 18, 2015 • 11 years ago #34960

Hi Swagatam,
is this circuit suitable to use with https://www.homemade-circuits.com/2013/04/automatic-micro-ups-circuit.html in order to make the Micro UPS auto cut off the load from battery ??

if yes what changes i have to make to support 4 or 5AMP load like Micro UPS does ?

if not what do you suggest to use with Micro UPS ?

thank you again and again @

Reply
SwagatamAdmin
October 19, 2015 • 11 years ago #34973

Hi Sina, the above circuit is not quite efficient with its detection, and also it could make the entire design too lengthy, so it's better to use the last circuit from this article:

https://www.homemade-circuits.com/2011/12/how-to-make-simple-low-battery-voltage.html

this will take care of the all the required safety conditions.

Reply
Shuddhatam Jain
October 27, 2015 • 11 years ago #35265

respective sir my name shuddhatam jain i likes your circuit digrame i need li-ion battery protection circuit i make Low Battery Cut-off and Overload Protection Circuit according to you in this circuit i don't understand what is meen by QUIZ = Explain the introduction of R4 and C1.
pl give mr reply

thankyou very much

Reply
SwagatamAdmin
October 28, 2015 • 11 years ago #35274

Hi Shuddhatam, thank you for appreciating my site.

the circuit required by you is already present in my blog, please use the search box above to find the preferred one of your choice.

R4 is for locking the relay when it clicks, and C4 is for preventing the chattering of the relay during the changeover action.

Reply
Angelous Chavez
October 31, 2015 • 11 years ago #35394

Sir, i interesting with this circuit. I am planning to make this circuit to add in my project. Can you give me s circuit for battery cut-off and overload protection for dc to ac inverters please if you have.

I am angelous from the philippines i am an electronics student.

I am hoping for your reply…

Thanks in advance.

Reply
SwagatamAdmin
November 1, 2015 • 11 years ago #35422

Angelous, I'll check and try to find one…

Reply
Shuddhatam Jain
November 4, 2015 • 11 years ago #35591

Respectiv sir 3 problems come me for making circuit Low Battery Cut-off and Overload Protection Circuit
1. this circuit work for this battery 18650 li-ion 11.1v 6.6Ah battery ?
2. what is R1 = 0.6/Trip Current and how many watt?
3. what is setting of pre set is mark for this battery?
i use this battery pack in hero honda(super splender) biky for the self starting
pl help me

thankyou

Reply
SwagatamAdmin
November 4, 2015 • 11 years ago #35595

Shuddhatam, I have already answered to the same question in the other article….please check it

Reply
ataull hakim
November 15, 2015 • 11 years ago #35888

Sir, can i use it as a solar charge controller for LVD circuit?

Reply
SwagatamAdmin
November 16, 2015 • 11 years ago #35922

yes it can be used

Reply
Olaleye Kolade
December 10, 2015 • 11 years ago #36609

Thanks for this simple circuit.
Am having little problem about the circuit, I build just the circuit and set it, everything is working, but my question is where will I connect the terminal mark load? Is it directly from inverter transfo output
2. The terminal mark battery is it the battery for the inverter or another battery. Please explain
Thanks

Reply
SwagatamAdmin
December 10, 2015 • 11 years ago #36615

The terminals indicated as "load" is connected with the inverter input supply terminals which is normally supposed to be connected with the battery directly.

and the terminals marked as "battery" should be connected with the inverter battery….not anything external.

with the above set up the battery power now enters the inverter through the above circuit's relay so that the required cut-off actions can be executed

Reply
rob wiseman
December 10, 2015 • 11 years ago #36630

Hi Swagman.

The P1 preset in your low voltage cutout says (10 preset) how many ohms is this component,,
regards Rob.

Reply
SwagatamAdmin
December 11, 2015 • 11 years ago #36635

Hi Rob, it's 10k, I have corrected the typo

Reply
kamran abbas
December 29, 2015 • 11 years ago #37150

Hi How are you
Sir
How can I make digital numbers display for example I have inverter and i want show inverter output voltage on display and also battery voltage

Reply
SwagatamAdmin
December 30, 2015 • 11 years ago #37178

Hi Kamran, you can make and use the following circuit and apply it in your inverter for the results:

https://www.homemade-circuits.com/2013/05/make-this-simple-digital-voltmeter.html

alternatively you can buy a readymade digital voltmeter module and use it for the same.

Reply
Robert Random
January 14, 2016 • 11 years ago #37608

Hi Swagatam,
Would there be a drain of the battery through P1, D1, R1, T1 when the circuit is off due to battery depletion? Thanks. ~Robert

https://www.circuitlab.com/circuit/227r5y/screenshot/1024×768/

Reply
SwagatamAdmin
January 14, 2016 • 11 years ago #37629

Hi Robert, it's possible only through P1, that is through the end terminals of the preset

Reply
adelusi oluwatosin
January 17, 2016 • 11 years ago #37750

Thank you so much sir. sir how can i select R1 for 1.5kva inverter? i.e the appropriate current sensor resistor for 1.5kva. Thanks.

Reply
SwagatamAdmin
January 18, 2016 • 11 years ago #37776

adelusi, divide 1500 with the battery voltage, and then divide 0.6 with this result.

Reply
vhafuwi
February 19, 2016 • 10 years ago #38940

Hi Swagatam

I require your assistance, I have installed an off-grid solar system for student residents ,just for them to use light , laptops and charge their cell phones , it is becoming difficult to control them since they have other high wattage appliances such as electric iron , boilers in their rooms, i require a help in designing a device that will shape the amount of watts or amps a students is allowed to use per room plug , the unit must only disconnect just the student who plug a overload appliance , i will appriciate your assistance , my email vhafuwi@gmail.com

Reply
SwagatamAdmin
February 20, 2016 • 10 years ago #38954

Hi vhafuwi,

you can try the following circuit

https://www.homemade-circuits.com/2015/03/mains-over-load-protector-circuit-for.html

install one such unit in every room after the mains DPDT switch

Reply
Shuddhatam Jain
February 26, 2016 • 10 years ago #39167

pl tell me where i purchases lm196 or 78h12a

Reply
Usa Juana
June 21, 2016 • 10 years ago #41995

Hello sir . am building the bubba osilator inverter and am adding the overload and no load detection circuits , please I have these question on those circuits .1, I have finished the oscilators and I am getting 1.4 Volts ac , is that OK?.2, for the sensing resistor of the overload circuit RESISTOR X I calculated 0.00909 ohm , so 12 0.1ohm in parallel will solve it but what wattage of resistor will be OK will 1/2 be OK as it is many?. 3,the no load detection circuit have 0.05 ohm so 2 0.1 ohm resistor will solve it , now this concern me more,what watts do I need to use so that it can with stand the 800watts inverter at its full operational power?

Reply
SwagatamAdmin
June 22, 2016 • 10 years ago #42003

Hello Usa,

please comment separately under those articles, so that I can refer to those diagrams and address the issues accordingly.

the bubba oscillator output needs to be processed to SPWM first in order to achieve sine wave output.

Reply
MORRIS CERULLO
July 1, 2016 • 10 years ago #42264

What should i do for this circuit to cut off at 8volt when using 12v 70amp-hour battery?

Reply
dawar jan
November 1, 2016 • 10 years ago #46064

What do u mean when the voltage cross 0.6v

Reply
SwagatamAdmin
November 2, 2016 • 10 years ago #46079

it is the triggering base voltage for T1

Reply
Wise Essien
May 5, 2020 • 6 years ago #78441

Hello sir I have challenge on how to build h_bridg inverter

Reply
dawar jan
November 2, 2016 • 10 years ago #46084

How does the circuit work.esplain step by step. How can i change it to only cut off at low voltage.reply plz

Reply
i.c.v. young king
April 22, 2017 • 9 years ago #49925

Pls sir can u send me the circuit diagram of low battery cut through this mail ,youngkingicv@gmail.com pls sir l'll be waiting thanks.

Reply
SwagatamAdmin
April 23, 2017 • 9 years ago #49931

ICV, you can refer to the following article for making a low battery cut off circuit

https://www.homemade-circuits.com/2011/12/how-to-make-simple-low-battery-voltage.html

Reply
Faith Jumbo
August 12, 2017 • 9 years ago #52376

in the case of inverter the load is were the ac is connected but in on one of the comments i read u said the entire circuit is connected to the dc side so how do we monitor the load since the load are the appliances since the appliances are connected to the ac side

Reply
SwagatamAdmin
August 12, 2017 • 9 years ago #52381

the load cannot be an AC load here, the circuit is designed for DC loads, if an inverter is connected as the load then the appliances consumption would be ultimately drawn from the battery, and therefore the circuit would sense it and trip if an overload from the appliance was detected.

Reply
moses kwagam
August 13, 2017 • 9 years ago #52391

Thank u Swagatam and every one participating in this blog. Pls how do I determine the trip current and/or the value of R1 if I want to make 1KVA inverter and I want the inverter to cut off when it senses 800 watts of load

Reply
SwagatamAdmin
August 13, 2017 • 9 years ago #52398

thanks moses, it can be calculated by the formula:

R = 0.6 / trip current

trip current = wattage/Voltage…in your case it will be 800 / battery voltage

Reply
Dady
August 25, 2018 • 8 years ago #62663

Sir I need overcharged protection circuit diagram and low battery cutoff circuit diagram. I built my inverter with SG3524 and its 24v. I would prefer the link sent to my mail: zuredu@gmail.com.
Thanks

Reply
SwagatamAdmin
August 25, 2018 • 8 years ago #62672

Dady, you can find many options under this category:

https://www.homemade-circuits.com/category/battery-cut-off-switch-diagrams/

Reply
Godson Ugo
August 30, 2017 • 9 years ago #52901

Hello sir Swagatam, I asked for an overload protection circuit for an inverter with auto-power off feature in the comment session of one of your posts and you referred me to this post. Having read through the post and comments, I concluded that I may not be able to use the circuit for the intended purpose. You explained in the comments that the inverter should me made the load but I’m afraid that I won’t be able to get the relay that can handle the huge current drain from the battery. So what I need is circuit that will be connected to the output side of the inverter transfo and which can operate a small 12V relay such that I can use the relay contacts to power off the inverter driver when overload is sensed at the inverter output. I’ll be glad if you could help me with such circuit. Thanks a lot sir.

Reply
SwagatamAdmin
August 30, 2017 • 9 years ago #52902

In that case you can try the concept explained in the following article:

https://www.homemade-circuits.com/2014/06/simple-current-sensor-circuit-modules.html

use the NPN version, and connect the collector with the mosfet gates via separate diodes or simply connect it with the “Ct” of the IC,…. for SG3525 you can use the PNP version, and connect the collector with pin#10 via a 1N4148 diode

Reply
Godson Ugo
August 30, 2017 • 9 years ago #52907

Ok sir. Thank you very much. I’ll check it out.

Reply
Abioye
February 20, 2018 • 8 years ago #58615

sir i have a 3000watt inverter built from a 650watt inverter with your honourable advice and guidance but i want to make a overload cutoff for it my maximum drain current from the battery is 125amp when i divide 3000watt by the batteries voltage which is 24v and it give me the R1 value of 0.0048 how many 0.1resistor do i wire in parrallel to achieve this value

Reply
SwagatamAdmin
February 21, 2018 • 8 years ago #58627

You will need 20 resistors in parallel. Each must be rated at 5 watts

Reply
Yusuf Abdlazeez
January 1, 2019 • 8 years ago #64782

Hi sir. Thanks for d job well done. The calculation of R1 is my prolem. You said R = 0.6/Trip current and TC = Wattage/Voltage. I get 0.00xx Can you explain more. Thanks and God bless.

Reply
SwagatamAdmin
January 1, 2019 • 8 years ago #64783

Thanks Yusuf, what trip current or max overload current are you trying to apply? please let me know I’ll solve it for you.

Reply
itar eric
March 24, 2019 • 7 years ago #66044

please sir, can I use the above circuit with my home made power inverter , will I connect the protection between the load and inverter or how do I connect it?if I can’t please I need an over load and short circuit protection circuit for 12v inverter and how to connect it, thank you sir

Reply
SwagatamAdmin
March 24, 2019 • 7 years ago #66045

Hi Itar,

yes you can use it for inverter overload protection. THe “LOAD” here is the inverter, so connect the inverter DC supply terminals across these points, and connect the battery on the right hand side as shown

Reply
Emmanuel John
July 9, 2019 • 7 years ago #68282

good day sir, i hope you’re doing well? back in a months, I ask you so many questions about inverter and the challenge which i had with the one I built. with your help, i had solve the challenge,my mosfet are not getting heat anymore ,tanks for the help. please Sir I am back with another question. question is that,can at the same time the inverter out put still charge the battery while is still working or ho can I make it work constant that is, without removing the battery to charge separate before used again?

Reply
SwagatamAdmin
July 9, 2019 • 7 years ago #68293

Hi Emmanuel, that’s not possible, your battery will get discharged and then you will have to switch OFF the inverter and charge the battery from an external source until its fully charged again

Reply
Saeed Abdullah
October 15, 2019 • 7 years ago #71081

Hi sir please i my circuit diagram and if i built it blow the mosfet and if
i can send my circuit diagram to check it if there is any problem then please you help me. Thanks sir

Reply
SwagatamAdmin
October 15, 2019 • 7 years ago #71086

there’s no mosfet in the diagram, it is a simple and a tested design and will work definitely, but only if you connect and set the circuit correctly

Reply
Saeed Abdullah
October 28, 2019 • 7 years ago #71473

hi sir, pls i have build inverter with ic TL494 plus mosfet irf3205 and if i connected with 12v battery it blow mosfet and i used ferrite core transformer and sir if you can help me with this issue I will be glad. Thank you

Reply
SwagatamAdmin
October 28, 2019 • 7 years ago #71476

Hi Saeed, if it is a ferrite based design then it can be difficult to troubleshoot for me, because ferrite trafos require strict calculations for the winding, and a wrongly built trafo can cause instant burning of the devices.

Reply
Daniel
April 3, 2021 • 5 years ago #88229

What is r1 I see 0.6 trip current is that 0.6 ohms resistor

Reply
SwagatamAdmin
April 3, 2021 • 5 years ago #88234

Please read the article, it is already explained.

Reply
ben
November 14, 2019 • 7 years ago #72053

Sir help me for 24v battery full cut off using opamp lm358
Please is ulgent

Reply
SwagatamAdmin
November 14, 2019 • 7 years ago #72064

Ben, you can try one of the designs explained in the following article:

https://www.homemade-circuits.com/opamp-low-high-battery-charger/

Reply
Robert Obiorah
March 30, 2020 • 6 years ago #77572

Sir, I have been having this constant problem with repair of Indian inverters. And it has to do with overload, no load, etc fault. Please, an you give me a clue as to how to tackle this issue. I have no idea where to start

Reply
SwagatamAdmin
March 30, 2020 • 6 years ago #77581

Robert, all inverters have different board configuration and component settings, so it can be difficult to judge their faults commonly…

Reply
Okanama
April 14, 2020 • 6 years ago #77887

I really appreciate this, I will only ask for a circuit that changes from the power station to inverter and vise versa.
When done, charging the batteries begins.

Reply
SwagatamAdmin
April 15, 2020 • 6 years ago #77899

You can probably try the following designs:

https://www.homemade-circuits.com/automatic-inverter-supply-and-mains/

https://www.homemade-circuits.com/how-to-convert-inverter-to-ups/

Reply
Joshua
April 19, 2020 • 6 years ago #78008

hello sir, im Joshua. i designed an inverter with sg3524 and it has been working perfectly but i have been having serious problems with the rate my batteries overcharged. the circuit does not have overcharged protection feature. could you please help me out?

Reply
SwagatamAdmin
April 19, 2020 • 6 years ago #78011

Hello Joshua, you can try the following concepts:

https://www.homemade-circuits.com/opamp-low-high-battery-charger/

or simply use a fixed regulated 14.1V as the input supply for the battery, without the need of any cut off circuit.

Reply
jay
August 9, 2020 • 6 years ago #81161

hello sir , i’am from philippines and a beginner electronic hobbyist. I have finish your circuit ‘low battery cutoff and overload’ installed on my oscillator circuit ( pwm inverter ) sg3525 ic (not on the battery side of the inverter ) .. I set the low battery cutoff to 11 volts and it is working perfectly on a small load like 60 watts electric fan, and 100 watts soldering iron , but when my load is 60 watts 21 inches crt television the relay will cutoff immediately .. I’am using 10 ampere relay and .02 ohm resistor for r1 .. please i need your help .

Reply
SwagatamAdmin
August 9, 2020 • 6 years ago #81163

Hello Jay, 60 watt fan/iron and 60 watt TV are similarly rated? May be the TV rating is much higher than 60 watt…But anyway 0.02 is too small and will NOT provide any current limit or over current protection below 30 amps, and 30 amps looks impractical for your application

Reply
Mark Rankin
December 23, 2020 • 6 years ago #85560

Hello,

Do low battery cutoff circuits wear out?

I have a 4000 watt inverter and I set the low battery cutoff to energize at 22 volts. This has worked well for 12 years. Lately, the cut off activates when any heavy load kicks in (water pump, refrigerator) even when the battery is fully charged.

I am trying to figure out if it’s a battery problem or an inverter problem.
Thanks in advance for any help you can provide.

Mark Rankin

Reply
SwagatamAdmin
December 23, 2020 • 6 years ago #85565

Hi, no they don’t, because cut off circuits are solid-state circuits, which will hardly ever blow, burn or degrade under normal conditions.
In your case it could be a battery problem which may be unable to provide the initial high current due to aging or internal degradation, causing the voltage to drop severely below the lower cut-off threshold.

Reply
Mark Rankin
December 23, 2020 • 6 years ago #85571

Thank you so much for this, Swagatam
About a month ago I installed a new 1236 amp-hour 24-volt battery (made for solar systems) by GB battery (a forklift battery company). It worked fine for about a month but I have my concerns now.
The battery seems to go through the inverter’s “3 stage” charge cycles very fast.
When the battery is at the “top” of a freshly charged cycle and it gets an inrush demand for amperage (blowing the low battery cut off) the voltage will drop way down to below 23 volts after the incident.
I have been watching my specific gravity which reads (with no load on it) 1.25 per cell when the battery is at the top of the charge.
Now I am concerned that this battery (even though they say it is made for solar) requires a different charging system.
It’s like, over the past month of usage, the battery has slowly been depleted even though the charge cycle on the inverter says it’s complete.
I will be calling the company in the morning. If any of this makes sense I would appreciate your input.

Reply
SwagatamAdmin
December 23, 2020 • 6 years ago #85574

You are most welcome Mark,
Now it seems there’s actually nothing wrong with the working of the various systems in your controller, and neither the battery.

The 3 step charger is designed to implement a fast charging on the battery, and for this initially during the first step it has to force a relatively high amount of current into the battery, which is readily accepted by the battery inducing the high surge current. As the battery charges, the charger reduce the current during the subsequent 2nd and the 3rd steps.

Therefore during the initial 1st step, the surge may be causing a steep drop in the charger voltage and tripping the low cut off.
To remedy the situation you can either adjust the 1st stage charging current to a lower level, or add some sort of delay feature to the low cut off, so that it doesn’t react to the initial momentary surge.

However, if your battery is showing depletion, that means its condition is deteriorating, perhaps due to the high current charging, in that case it would be better to change the 3 step charger into a regular 1 step charger which will enable a moderately slow charging and ensure longer life for the battery and also stop the low voltage cut off tripping

Reply
Mark
December 23, 2020 • 6 years ago #85577

Swagatam,
You are a rare find, thank you so much for sharing your knowledge. Just being able to bounce these problems off someone of your caliber is such a gift for me right now.
I will attempt to make the changes you suggested, I hope you and your family have a Merry Christmas.

Mark

Reply
SwagatamAdmin
December 24, 2020 • 6 years ago #85590

It is a pleasure Mark, always happy to help! Wish you all the best, and Merry Christmas to you too!

Reply
Mark Rankin
December 24, 2020 • 6 years ago #85586

I think I found the problem!!!

I did a gravity test on all twelve cells tonight, this battery is only two months old. To my surprise, I found one cell that did not even float the hydrometer indicator, it read 0 volts on the multimeter. Not sure how I missed this before. I am contacting the company about a replacement cell (hopefully under warranty) this week.

I just wanted to pass on the good news.
Thanks again, Swagatam!

Reply
SwagatamAdmin
December 24, 2020 • 6 years ago #85591

Sounds great, Glad you could find the fault so quickly!

Reply
Daniel
April 3, 2021 • 5 years ago #88226

Ok I understand but I really like to know if this simple circuit is for 12volt only cause I am wondering if this circuit is sufficient to manage up to the high amp draw on the battery cause inverter need alot of amperage to convert

Reply
SwagatamAdmin
April 3, 2021 • 5 years ago #88233

This circuit can be upgraded to any desired limits by changing the transistor and the relay, and the resistor values accordingly.

Reply
Roger Versteeg
April 13, 2021 • 5 years ago #88422

I would like to use the circuit here to cut off the battery power when the 12V goes too low and then automatically turn it back on when it is okay. However, it looks like it won’t turn back on unless you press the button. How do I avoid that button? I looked at your low battery indicator circuit (https://www.homemade-circuits.com/how-to-make-simple-low-battery-voltage/) but that is unclear right now.

Reply
SwagatamAdmin
April 13, 2021 • 5 years ago #88432

The second and the last circuits will do automatic switch ON and switch OFF for charging the battery

Reply
Joshua
April 18, 2021 • 5 years ago #88552

What’s the exact values of R1 for 12v and 24v batteries?

Reply
SwagatamAdmin
April 18, 2021 • 5 years ago #88557

R1 will depend on the load current, not the voltage.

Reply
SAJI TR
May 24, 2021 • 5 years ago #90524

Ic741 can be good but what should be the value of Rx resistance in a500watts 12 volts operated inverter

Reply
SwagatamAdmin
May 24, 2021 • 5 years ago #90528

RX = 0.6 / max current limit

Reply
Emmanuel
May 28, 2021 • 5 years ago #90596

That is R1 is will have a resistance of a fuse resistor?

Reply
Emmanuel
May 28, 2021 • 5 years ago #90595

Thank you for this. Please how would you calculate R1

Reply
SwagatamAdmin
May 28, 2021 • 5 years ago #90597

R1 is the sensing resistor. It can be calculated using the formula
R1 = 0.6 / Max current

Reply
eniola
August 27, 2021 • 5 years ago #95718

great idea sir, may the lord increase you in wisdom. sir, the second circuit i want to connect it with my 3000w inverter and my rx value after calculated is 0.007 i.e im using 12v battery and voltage cutoff for 1000w load.i want to ask for the resistor value in ohms and how many in parallel

Reply
SwagatamAdmin
August 28, 2021 • 5 years ago #95756

Thank you eniola, the formula is 0.6/max current limit, so please calculate it as per your inverter specifications

Reply
Sead
October 18, 2021 • 5 years ago #101774

Hello,
You explained this great. Just how do I determine this RX resistor if the inverter is a maximum of 200w, I would like to put a limiter at 160w, over to turn off the relay or how do you think it should?
I would ask you for help. BR

Reply
SwagatamAdmin
October 18, 2021 • 5 years ago #101792

Hello, and glad you found the idea helpful. Rx in the last diagram can be determined using the following formula:

RX = 0.6 / Max current

For 160 watt, you can divide it with the supply voltage to get the Max current value.

Reply
Sead
October 19, 2021 • 5 years ago #101870

Hello ,
Thanks for the quick answer . Can only the power supply for the SG3525 be interrupted via a relay so that the whole plus does not go through the relay?

Reply
SwagatamAdmin
October 19, 2021 • 5 years ago #101882

Hello, yes it possible, you can refer to the following articles to learn more about it:

https://www.homemade-circuits.com/dc-to-dc-converter-circuits-using-sg3524-buck-boost-designs/

https://www.homemade-circuits.com/inverter-circuit-with-feedback-control/

https://www.homemade-circuits.com/lm3524-datasheet-pinout-function-how-to-use/

Reply
Sead
October 19, 2021 • 5 years ago #101881

In fact, I’m running some shielded from deep discharge, but so that the device at 10.5V is turned off and does not turn on until it is reset by removing the terminal or on the main switch. Overload protection is not really necessary but it may not matter

Reply
SwagatamAdmin
October 19, 2021 • 5 years ago #101903

It is given in the first two diagrams of the following article

https://www.homemade-circuits.com/sg3525-pure-sinewave-inverter-circuit/

Reply
Ordu Prudence
August 12, 2022 • 4 years ago #132275

Hello sir
Thanks for this circuit
I’ve been searching for this kind of circuit for long
My question is this:
The Rx resistor which is calculated using 0.6/max current is it in ohmns or kilo-ohomns

Reply
SwagatamAdmin
August 12, 2022 • 4 years ago #132285

Hello Ordu,
The RX value will be in Ohms

Reply
J K BARIK
February 6, 2022 • 4 years ago #111759

Hello swagatam
I am already using solar panel at home using 1100VA inverter. I try to include my fridge which is 200watts. But the starting current is high. It trips at overload. Can I by pass overload and put a 30amp fuse for protection?
Hope you fine

Reply
SwagatamAdmin
February 7, 2022 • 4 years ago #111848

Hello JK, if your fridge is in a good condition and working correctly then you can easily bypass the overload controller with a calculated fuse. It is perfectly fine to do so.

Reply
j k barik
February 7, 2022 • 4 years ago #111866

Hello Swagatam
thanks for reply.
I am thinking the same to do. I will identify the micro-cont overload input pin (may be 4 / 5 in 16F72 for EB700)
and put a 30amp fuse.

thanks

Reply
SwagatamAdmin
February 7, 2022 • 4 years ago #111870

No Probem JK, hope it works for you!

Reply
yusuf
February 10, 2022 • 4 years ago #112225

in the first circuit,if the load current is say 10amp what will be the wire thickness at the load and battery side.

Reply
SwagatamAdmin
February 10, 2022 • 4 years ago #112234

You can use a wire with 2 to 3 mm thick copper core

Reply
Prabhat Sharma
February 14, 2022 • 4 years ago #112661

Please clear the working of this circuit on No load , on load with low current and On over current(short circuit).

Also What is the use of D1 and R4?

Reply
SwagatamAdmin
February 14, 2022 • 4 years ago #112667

On no load and low current the relay will be ON normally. Over current situation is explained in the article. D1 is to make T2 respond only to genuine signals, to make its operation more reliable. R4 is actually not required, you can remove it.

Reply
Sajith Kariyapperuma
October 14, 2022 • 4 years ago #133939

I need to use the RX for 12V 30Amp Battery. So What should be the RX Value. My inverter is 1000W

Reply
SwagatamAdmin
October 14, 2022 • 4 years ago #133942

A 12V 30 Ah battery cannot be used for a 12V 1000 watt inverter, because the recommended discharge rate of your 30 Ah battery is only 3 to 5 amp which is negligibly small for a 1000 watt inverter

Reply
sajith Kariyapperuma
October 15, 2022 • 4 years ago #133953

Thanks. I going to use 120A battery according to the formula which you have given to calculate RX value. So then what will be the RX value that i should use

Reply
SwagatamAdmin
October 15, 2022 • 4 years ago #133954

The maximum recommended discharge rate of a lead battery is around 15% of its Ah rating. So 15% of 120 will be 18 amps.
Now 18 x 12V = 216 watts. So your inverter can produce a maximum of 216 watts, not 1000 watts.

For 18 amp current, the RX value will be

RX = 0.7 / 18 = 0.038 ohms
power will be 0.7 x 18 = 12.6 watts or 15 watts.

Reply
sajith Kariyapperuma
October 15, 2022 • 4 years ago #133956

Thanks for your quick reply.
SO If I want to make a 1000W inverter what kind of battery should I use.
if as you say 120Amp battery can produce 216watts for thousand watts do i need to select a battery around 120Amp X 5 times.

in that case i there are UPS for computers 1200Kva. they use only 12v 7Amp X 2 batteries only. I know that the time duration will be max 15 to 20 minutes.

My target is to use this in my home. so what should I do as you think…..

Reply
SwagatamAdmin
October 15, 2022 • 4 years ago #133960

That’s correct! If you want a long life for your lead acid battery then you must not discharge it beyond 15% of its Ah rating. Alternatively you can increase the voltage rating of the battery and the inverter to get proportionately higher power output.

If you discharge the battery at 100% of its Ah rating then the battery will get destroyed very soon, unless the battery is a Li-Ion battery.

If you use a 120 Ah battery then to get 1000 watts you must discharge the battery at 1000 / 12 = 84 amps rate, which will destroy the battery after a few charge discharge cycles.

You will need a 12V 800 Ah battery for operating 1000 watt load for 5 hours or more.

By the way you can try 120 Ah battery and check the results.

Reply
sajith Kariyapperuma
October 15, 2022 • 4 years ago #133964

Thank You. I will try it with by increasing battery to 800Ah.
will inform you the results if I succeed..

Reply
SwagatamAdmin
October 15, 2022 • 4 years ago #133965

Sure, no problem!

Reply
Sajith Kariyapperuma
October 14, 2022 • 4 years ago #133940

i’m trying out Your Overload Protector Circuit

Reply
Michael
October 3, 2023 • 3 years ago #145739

Can I use same circuit for 24v inverter

Reply
SwagatamAdmin
October 3, 2023 • 3 years ago #145744

Yes, but replace the relay with a 24V relay and for the op amp circuit replace the 741 with LM358 op amp.

Reply
Michael Ojobi
October 4, 2023 • 3 years ago #145784

Thanks for your quick response sir, but
the lm358 which you said I should how dual output, is it one of the output I need? Please help me with the circuit sir

Reply
SwagatamAdmin
October 4, 2023 • 3 years ago #145789

Sorry, I cannot understand your question, what is the need of a dual output? the 741 circuit uses a relay for the cut off.

Reply
Michael Ojobi
October 4, 2023 • 3 years ago #145792

Okay, thank you sir

Reply
Michael Ojobi
October 4, 2023 • 3 years ago #145793

But what I mean before is, the ic lm358 have two output at pin 1 and pin 7, so it’s only one section I will use?

Reply
SwagatamAdmin
October 4, 2023 • 3 years ago #145795

Yes that is correct, you will have to use only one op amp among the two!

Reply
Michael Ojobi
October 4, 2023 • 3 years ago #145810

Thank you for the clarification, I have did it in project board but didn’t cut off when the battery is low at 10.4v

Reply
SwagatamAdmin
October 5, 2023 • 3 years ago #145840

The transistor circuit cannot be very accurate, if you need more accuracy you may have to use an op amp circuit.

Reply
Michael Ojobi
October 5, 2023 • 3 years ago #145845

Yes, the one I used was that op amp circuit but ic is lm358 which didn’t cut off voltage at 10.4v,

Reply
SwagatamAdmin
October 5, 2023 • 3 years ago #145846

The op amp circuit is an overload cut off circuit, it is not a low voltage cut off circuit.

Reply
Michael Ojobi
October 5, 2023 • 3 years ago #145847

Okay sir, but how can I get accurate circuit for low voltage protection and over load protection

Reply
SwagatamAdmin
October 5, 2023 • 3 years ago #145848

Michael, You can try the second design from the following article. Just make sure to make two changes. 1) Swap the pin2 and pin3 with each other. 2) Replace the “charging voltage input” with Inverter supply +/- inputs.
https://www.homemade-circuits.com/how-to-make-simple-low-battery-voltage/

Reply
Michael Ojobi
October 6, 2023 • 3 years ago #145885

Thank you so much sir, I love that circuit that have low voltage protection and charger, it will be very good for inverter. Thanks sir

Reply
SwagatamAdmin
October 6, 2023 • 3 years ago #145902

You are welcome Michael, I hope you are able to build it successfully.

Reply
Michael
October 8, 2023 • 3 years ago #145998

Hello sir, if I use small transformer 220v to 12v for bridging diode to charger oscillation and use 30ahs relay for the charging output, will I have high current to charge battery?

Reply
SwagatamAdmin
October 8, 2023 • 3 years ago #146010

The output current depends on the transformer current, so the transformer current must be according to the battery requirements.

Reply
Michael Ojobi
October 6, 2023 • 3 years ago #145909

I have not yet work on the circuit but, I understand it very well sir. Sir! Is there a way that I use same transformer for both inverter and charger?

Reply
SwagatamAdmin
October 6, 2023 • 3 years ago #145913

I wouldn’t recommend using a single transformer for both charging and the inverter as that can make the configuration too messy and difficult to optimize. Still, if you are willing to give it a try you can consider the following article:

https://www.homemade-circuits.com/single-transformer-inverterchargerchang/

Reply
Segun
October 23, 2023 • 3 years ago #146424

Please what is the RX resistor

Reply
SwagatamAdmin
October 23, 2023 • 3 years ago #146425

RX = 0.7 / Max over load current

Reply
Raed
November 21, 2023 • 3 years ago #147218

Is it possible to use N-MOS instead of BC547 transistor?

Reply
SwagatamAdmin
November 21, 2023 • 3 years ago #147221

Sorry, no, only NPN BJTs are recommended.

Reply
Yahya
December 5, 2023 • 3 years ago #147739

Hello, I have a question: Does the second circuit work as a short circuit protection at any point in the inverter?

Reply
SwagatamAdmin
December 5, 2023 • 3 years ago #147740

Yes, it will work as a short circuit and overload cut off circuit.

Reply
Hillary
April 9, 2024 • 2 years ago #151441

Good evening sir, please what value of shunt resistor can be used for 1000w inverter

Reply
SwagatamAdmin
April 9, 2024 • 2 years ago #151448

Hi Hillary, Please provide the inverter operating voltage value.

Reply
Hillary
December 18, 2024 • 2 years ago #167418

The battery voltage is 12v

Reply
chuks
July 12, 2024 • 2 years ago #154434

how do i calculate the over load current of 1KVA inverter

Reply
SwagatamAdmin
July 13, 2024 • 2 years ago #154543

Simply divide 1kva (1000 watts approx) with your battery voltage.

Reply
Ibrahim musa wakili
December 3, 2024 • 2 years ago #166483

how can I determine the Rx

Reply
SwagatamAdmin
December 3, 2024 • 2 years ago #166501

RX = 0.7 / Maximum inverter current limit

Reply
Hillary
December 18, 2024 • 2 years ago #167419

Good day sir, I made the battery low cut off and it works fine but then, when the circuit is activated at 10.5v, it automatically deactivates itself when the voltage goes back to 10.7v and this continues. So I want to ask if there is any other circuit to add to keep it activated until a reset button is pressed?

Reply
SwagatamAdmin
December 18, 2024 • 2 years ago #167423

Hillary, which circuit are you using? It can be be latched using an SCR stage. Let me know which circuit are you using, I will try to modify it accordingly.

Reply
Hillary
December 18, 2024 • 2 years ago #167426

I am using Opamp circuit

Reply
SwagatamAdmin
December 18, 2024 • 2 years ago #167427

The opamp circuit is not a low battery cut off circuit, it is an overcurrent/overload cut-off circuit, and it has a latching feature already.

Reply
Murat bayındır
December 28, 2024 • 2 years ago #167594

Düşük voltaj kesme devresinde role yerine paralel bağlı mosfetler kullanılabilir mi teşekkür ederim.

Reply
Hillary
February 4, 2025 • 1 year ago #168280

Good day sir, thank you for all your good works here. You have really helped so many especially me. More grease to your elbow.
I made an automatic low battery cut off circuit but it comes back on immediately the battery voltage increases above the cutoff level. Please help me with a circuit that will keep the Auto low battery cut off inactive until a preset button is pressed

Reply
SwagatamAdmin
February 4, 2025 • 1 year ago #168282

You are welcome Hillary,
In your existing circuit please connect a high value resistor between 10k and 100k, between the N/C contact of the relay and the base of the relay driver transistor. Next, attach a push-button between emitter/collector of the transistor for the resetting the action.

Reply
Hillary
February 4, 2025 • 1 year ago #168284

I have done it but when an inductive load is connected to the inverter, the relay flickers

Reply
SwagatamAdmin
February 4, 2025 • 1 year ago #168286

To control relay flickering, just connect a 220uF or a 470uF capacitor across the relay coil, make sure to connect it with correct polarity.

Reply
abdulkareem
April 3, 2025 • 1 year ago #171393

sir how are you
I make construction inverter using sg3525 mosfet 4 ups transformer I tested output 473v AC
how decrease. voltage to 220

Reply
SwagatamAdmin
April 3, 2025 • 1 year ago #171397

Abdulkareem,
It means, the transformer winding ratio is not suitable for 220V AC output, please change the secondary number of turns to get 250V, instead of such high value…

Reply
Asikpo Okon
September 12, 2025 • 11 months ago #185203

pls sir can help with your email or link I can use and send an image to, I have this variable power supply circuit but I want you to help preview it if there’s any error. before implement the circuit or budget for it

Reply
SwagatamAdmin
September 12, 2025 • 11 months ago #185206

Hi Okon, please upload it to your google drive and provide the “shared” link to me and I will check it out.
But please, for a power supply related article, please post it under a power supply related article…

Reply
« Back to Newest Comments

Need Help? Please Leave a Comment! We value your input—Kindly keep it relevant to the above topic! Cancel reply

Your email address will not be published. Required fields are marked *

Primary Sidebar



Categories

  • Arduino Projects (95)
  • Audio and Amplifier Projects (134)
  • Automation Projects (18)
  • Automobile Electronics (103)
  • Battery Charger Circuits (89)
  • Datasheets and Components (109)
  • Electronics Theory (150)
  • Energy from Magnets and Earth (40)
  • Games and Sports Projects (11)
  • Grid and 3-Phase (20)
  • Health related Projects (27)
  • Home Electrical Circuits (13)
  • Indicator Circuits (16)
  • Inverter Circuits (100)
  • Lamps and Lights (163)
  • Meters and Testers (72)
  • Mini Projects (28)
  • Motor Controller (68)
  • Oscillator Circuits (30)
  • Pets and Pests (15)
  • Power Supply Circuits (91)
  • Remote Control Circuits (50)
  • Security and Alarm (65)
  • Sensors and Detectors (107)
  • SMPS and Converters (46)
  • Solar Controller Circuits (62)
  • Temperature Controllers (44)
  • Timer and Delay Relay (50)
  • Voltage Control and Protection (44)
  • Water Controller (37)
  • Wireless Circuits (31)



Circuit Simulator

circuit simulator image



Subscribe to get New Circuits in your Email



Other Links

  • Privacy Policy
  • Cookie Policy
  • Disclaimer
  • Copyright
  • Videos
  • Sitemap

People also Search

555 Circuits | 741 Circuits | LM324 Circuits | LM338 Circuits | 4017 Circuits | Ultrasonic Projects | SMPS Projects | Christmas Projects | MOSFETs | Radio Circuits | Laser Circuits | PIR Projects |



Recent Comments

  • Swagatam on 2 Cool 50 Watt Inverter Circuits for Students and Hobbyists
  • Swagatam on The Perfect FM Radio Circuit using TDA7000 IC
  • Swagatam on 9 Simple Sine Wave Generator Circuits Explored
  • way on 2 Cool 50 Watt Inverter Circuits for Students and Hobbyists
  • Athull on The Perfect FM Radio Circuit using TDA7000 IC

Social Profiles

  • Twitter
  • YouTube
  • Instagram
  • Pinterest
  • My Facebook-Page
  • Stack Exchange
  • Linkedin

© 2026 · Swagatam Innovations