You are here: Home / Inverter Circuits / 500 Watt Inverter Circuit with Battery Charger

500 Watt Inverter Circuit with Battery Charger

Last Updated on August 3, 2020 by Swagatam 91 Comments

In this post we will comprehensively discuss how to build a 500 watt inverter circuit with an integrated automatic battery charger stage.

Further in the article we will also learn how to upgrade the system for higher loads and how to enhance ot into a pure sine wave version.

This 500 watt power inverter will convert a 12 V DC or 24 V DC from a lead acid battery to 220 V or 120 V AC, which can be used for powering all types of loads, right from CFL lights, LED bulbs, fans, heaters, motors, pumps, mixers, computer, and so on.

Basic Design

An inverter can be designed in many different ways, simply by replacing the oscillator stage with another type of oscillator stage, as per user preference.

The oscillator stage is basically an astable multivibrator which could be using ICs or transistors.

Although an astable based oscillator can be designed in various ways, we will use the IC 4047 option here since it is a versatile, accurate and a specialized astable chip designed specifically for applications like inverers.

Using IC 4047

Making any inverter using the IC 4047 is probably the most recommended option due to high accuracy and readability of the IC. The device is a versatile oscillator IC which provides a dual push pull or flip flop output across its pin10 and pin11, and also a single square wave output at pin13.

BASIC CIRCUIT

A basic 500 watt inverter with a square wave output can be as simple as above to build. However, to upgrade it with a battery charger we may have to employ a charger transformer rated appropriately as per the battery specifications.

Before learning the charger configuration let's first get acquainted with the battery specification required for this project.

From one of our previous post we know that the more appropriate charging and discharging rate of a lead acid battery should be at 0.1C rate or at a supply current that's 10 time less than the battery Ah rating. This implies that to get a minimum of 7 hours back up at 500 watt load, the battery Ah could be calculated in the following manner

Operational current required for a 500 watt load from a 12V battery will be 500 / 12 = 41 Amps approximately

This 41 amps needs to last for 7 hours, implies that the battery Ah must be = 41 x 7 = 287 Ah. However, in real life this will will need to be at least 350 Ah.

For a 24 V battery this may come down to 50% less at 200 Ah. This is exactly why a higher operational voltage is always advised as the wattage rating of the inverter gets on the higher side.

Using 24 V Battery

In order to keep the battery and the transformer size smaller and cables thinner, you may want to use a 24 V battery for operainf the proposed 500 watt design.

The basic design would remain as is, except a 7812 IC added to the IC 4047 circuit, as shown below:

Schematic Diagram

Battery Charger

To keep the design simple yet effective, I have avoided the use an automatic cut off for the battery charger here, and have also ensured a single common transformer is used for the inverter and the charger operations.

The complete circuit diagram for the proposed 500 watt inverter with battery charger can be seen below:

The same concept has been already elaborately discussed in one of the other related posts, which you can refer to for additional information.

Basically, the inverter uses the same transformer for charging the battery and for converting the battery power to 220 V AC output. The operation is implemented through a relay changeover network, that alternately changes the transformer winding to charging mode and inverter mode.

How it Works

When grid mains AC is not available, the relay contacts are positioned at their respective N/C points (normally closed). This connects the drains of the MOSFETs with the transformer primary, and the appliances or the load connect with the secondary of the transformer.

The unit gets into inverter mode and begins generating the required 220V AC or 120 V AC from the battery.

The relay coils are powered from a simple crude transformerless (capacitive) power supply circuit using a 2uF / 400V dropping capacitor.

The supply is not required to be stabilized or well regulated because the load is in the form of the relay coils which are quite heavy duty and will easily withstand the switch ON surge from the 2uF capacitor.

The coil for RL1 relay which controls the mains AC side of the transformer can be seen connected before a blocking diode, while the coil of RL2 which controls the MOSFET side is positioned after the diode and in parallel to a large capacitor.

This is intentionally done to create a small delay effect for RL2, or to ensure RL1 switches ON and OFF prior to RL2. This is for safety concerns, and to ensure that the MOSFETs are never subjected to the reverse charging supply whenever the relay moves from inverter mode to charging mode.

Safety Suggestions

As we know, in any inverter circuit the transformer works like an heavy inductive load. When such a heavy inductive load is switched with a frequency, it's bound to generate a massive amount current spikes which may be potentially dangerous for the sensitive electronics and the involved ICs.

To ensure proper safety to the electronic stage, it may be important to modify the 7812 section in the following manner:

For a 12V application, you can reduce the above spike protection circuit to the following version:

Battery, MOSFET and Transformer Determine the Wattage

We have discussed this many times through different posts that it is the transformer, the battery, and the MOSFET ratings that actually decide how much power an inverter can produce.

We have already talked about the battery calculations in the previous paragraphs, now let's see how the transformer can be calculated for complementing the required power output.

It is actually very simple. Since the voltage is supposed to be 24 V, and power 500 watts, dividing 500 with 24 gives 20.83 amps. Meaning the transformer amp rating must be above 21 amps, preferably up to 25 amps.

However, since we are using the same transformer for both charging and inverter modes, we have to select the voltage in such a way that it suits both the operations optimally.

A 20-0-20 V for the primary side appears to be a good compromise, in fact it is the ideally suited rating for the overall working of the inverter across both the modes.

Since, only one half winding is used for charging the battery, the 20 V RMS rating of the transformer can be used for getting a 20 x 1.41 = 28.2 V peak Dc across the battery with the help of the associated filter capacitor connected across the battery terminals. This voltage will charge the battery at good rate and at the correct speed.

In the inverter mode, when the battery is at around 26 V, will allow the inverter output to be at 24/26 = 220 / Out

Out = 238 V

This looks a healthy output while th battery is optimally charged, and even when the battery drops to 23 V, the output can be expected to sustain a healthy 210V

Calculating MOSFET: MOSFETs basically work like switches that must not burn while switching rated amount of current, and also must not heat up due to increased resistance to switching currents.

To satisfy the above aspects, we have to make sure that the current handling capacity or the ID spec of the MOSFET is well over 25 amps for our 500 watt inverter. Also to prevent high dissipation and inefficient switching the MOSFET's RDSon spec must be as low as possible.

The device shown in the diagram is IRF3205, which has an ID of 110 amp and RDSon of 8 milliohms (0.008 Ohms), which actually looks quite impressive and perfectly suitable for this inverter project.

Parts List

To make the above 500 watt inverter with battery charger, you will need the following bill of materials:

  • IC 4047 = 1
  • Resistors
  • 56K = 1
  • 10 ohms = 2
  • Capacitor 0.1uF = 1
  • Capacitor 4700uF / 50 V = 1 (across the battery terminals)
  • MOSFETs IRF3205 = 2
  • Diode 20 amp = 1
  • Heatsink for the MOSFETs = Large Finned Type
  • Blocking Diode Across MOSFETs Drain/Source = 1N5402 (Please connect them across drain/source of each MOSFET for added protection against reverse EMF from the transformer primary. Cathode will go to the drain pin.
  • Relay DPDT 40 amp = 2 nos

Upgrading to Modified Sinewave Inverter

The square wave version discussed above can be effectively converted into a modified sinewave 500 watt inverter circuit with much improved output waveform.

For this we use the age old IC 555 and IC 741 combination for manufacturing the intended sine waveform.

The complete circuit with battery charger is given below:

The idea is the same which has been applied in a few of the other sinewave inverter designs in this website. It is to chop the gate of the power MOSFETs with calculated SPWM so that a replicated high current SPWM is oscillated across the push pull winding of the transformer primary.

The IC 741 is used as a comparator which compares two triangle waves across its two inputs. The slow base triangle wave is acquired from the IC 4047 Ct pin, while the fast triangle wave is derived from an external IC 555 astable stage. The result is a calculated SPWM at pin6 of the IC 741. This SPWM is chopped at the gates of the power MOSFETs which is switching by the transformer at the same SPWM frequency.

This results in the secondary side with a pure sinewave output (after some filtration).

Full Bridge Design

The full bridge version for the above concept ca be built using the below given configuration:

For sake simplicity, an automatic battery cut off is not included, so it is recommend to switched OFF the supply as soon as the battery voltage reaches the full charge level. Or alternatively you may add an appropriately filament bulb in series with the charging positive line of the battery, to ensure a safe charging for the battery.

If you have questions or doubts regarding the above concept, the comment box below is all yours.




Previous: 3 Terminal Fixed Voltage Regulators – Working and Application Circuits
Next: How to Make PCB at Home

About Swagatam

I am an electronic engineer (dipIETE ), hobbyist, inventor, schematic/PCB designer, manufacturer. I am also the founder of the website: https://www.homemade-circuits.com/, where I love sharing my innovative circuit ideas and tutorials.
If you have any circuit related query, you may interact through comments, I'll be most happy to help!

You'll also like:

  • 1.  SG 3525 Automatic PWM Voltage Regulation Circuit
  • 2.  Pure Sine Wave Inverter Circuit Using IC 4047
  • 3.  Homemade 2000 VA Power Inverter Circuit
  • 4.  Convert your Computer UPS to Home UPS
  • 5.  How to Generate Electricity from Shoe while Walking
  • 6.  1500 watt PWM Sinewave Inverter Circuit

Please Subscribe (Only if you are Genuinely Interested in our Newsletters)


 

Reader Interactions

Comments

    Your Comments are too Valuable! But please see that they are related to the above article, and are not off-topic! Cancel reply

    Your email address will not be published. Required fields are marked *

  1. Search Related Posts for Commenting

  2. Taofeek says

    Let’s assume I upgraded my inverter up to 2000w, can I use it to iron my clothes, powering my electric cooker and the likes?

    Reply
    • Swagatam says

      Sure you can….

      Reply
    • Clarhem Armram says

      Dear Swagatam, I want to congratulate you for your admirable work, since today there are few people who offer their knowledge in this professional and disinterested way solely for the purpose of teaching.
      Excuse my inconvenience, maybe you can help me with the pcb layout of this inverter with 500w battery charger

      Reply
      • Swagatam says

        Thank you Clarhem, sorry I do not have the PCB details for this project, you can contact any professional PCB designer for the same, they will surely help you out with some charges.

        Reply
  3. Paul Basant says

    hi Swagatam i would like to know how a ups can be transformed into a 12volt to 240volt inverter, currently when pluged just on battery it goes off automatically in 15 mins, how can i make it on continiuosly with being off automatically in 15 mins with 12volt battery use.

    Reply
    • Swagatam says

      Hi Paul, yes it can be done, by removing all the relay changeover stages and by connecting the load directly across the secondary of the transformer.

      Reply
      • Evans says

        Hi sir,I have some questions regarding the above articles.
        1. With 56k and 0.1uf capacitor, what is the output frequency?
        2. For the h bridge,you haven’t provided the down and how to configure it.
        3. Sir can you help upgrade the h bridge to use all N channel mosfets using discrete components and cd4047 as our osciliation and incorporate the spwm as in the above article.

        Thanks in advance and look forward to your response.

        Reply
        • Swagatam says

          Hi Evans, the frequency will be approximately 50 Hz, but might need some further adjustments to ensure a precise 50 Hz.
          The SPWM configuration procedure will be the same as done for the center tap version. Instead of connecting the op amp output directly with the MOSFeT gates, you can add a BjT stage, and used their bases for the SPWM chopping.
          For Nchannel H bridge I have already explained the method for SG3525 circuit, you can apply the same comcept here also.

          Reply
          • Evans says

            Sir,what kind of adjustments please? Again sir for h bridge,we got the high side and the lower side,how is the connection of the spwm?

            Reply
            • Swagatam says

              Evans, Adjustment of the 56k resistor or the capacitor value…please build the basic design first after that we will try to solve the SPWM

  4. jefson josy says

    hi sir i have certain doubts in making an inverter with some specific specification for a certain purpose.It will be really useful if i get a chance to contact you through phone or email please.

    Reply
    • Swagatam says

      Hi jefson, I can discuss only through this platform, and not through telephone or email

      Reply
      • Evans says

        Again sir,can I use this inveter to power a refrigerator?

        Reply
        • Swagatam says

          Yes if the output wattage of the inverter is calculated according to the fridge requirement

          Reply
  5. OGUNFESOLA KEHINDE says

    Sir, help me with the inverter battery automatic charger circuit diagram.

    Reply
    • Swagatam says

      Here’s a suitable link you may try:
      https://www.homemade-circuits.com/opamp-low-high-battery-charger/

      Reply
  6. Ravi Kumar says

    Dear Sir,
    I am looking for a sine wave inverter circuit with 48V/72V to 440VAC ( two individual windings of 0-230 with phase shift capacitors also serves) of 2KVA with a relay (Invertor on mode) on technology transfer basis.
    This can be based on arduino/pic/sg3524.

    Reply
    • Swagatam says

      Dear Ravi, Sorry, I do not have the sufficient information regarding the specified inverter design, at this moment.

      Reply
      • Felix says

        Good day sir, please what are the requirement for designing a 3000watt inverter.

        Reply
        • Swagatam says

          Hi Felix, for upgrading to higher wattage, you only have to add more MOSFETs in parallel, increase supply voltage to the transformer up to 48 V 70 amps, and battery up to 48 V 500 Ah

          Reply
  7. George C Nwoche says

    Please if one wants to construct a 3kva center tap transformer, what will be the size of the copper wire and the number of turns for 240vs.

    Reply
  8. Mike Wyatt says

    Dear Swagatam
    Re 500W Inverter with charger.
    Thanks for you prompt reply. Whist I appreciate that the schematic has some additional components (for safety purposes) not shown in the List of Parts, please would you advise the values of these components, so that I can incorporate them into the circuit.
    Many thanks
    Mike

    Reply
    • Swagatam says

      Thank you Mike, the values are already given in the subsequent diagrams:
      https://www.homemade-circuits.com/wp-content/uploads/2019/11/spike-protection.png

      all the resistors are 1/4 watt 5% CFR, capacitors have voltage rating two times more than the battery voltage.

      Reply
  9. Mike Wyatt says

    I’d like to build this inverter (without the battery charger, as I plan on using solar power), but I have a problem tying up the components on the schematic with the List of Parts.
    Parts List specifies 3 resistors (10 Ohms X 2 and 56k Ohms X 1), but schematic shows 5. Likewise Parts List specifies 2 (0.1 uF and 4700 uF) capacitors, but schematic shows 3.
    Would appreciate clarification on those two issues, otherwise, everything else makes sense.
    Cheers
    Mike

    Reply
    • Swagatam says

      If the schematic shows some extra parts, there’s no harm in adding those. The parts list suggests the bare minimum parts required for building the basic 500 watt inverter, whereas the schematic shows some extra features for ensuring better safety to the circuit.

      Reply
  10. Ramaiah Thambi says

    Why don’t I get 500W with 12V 100Ah battery? I get 1200W I think. What about hot transistors?

    Reply
    • Swagatam says

      With a 100 Ah lead acid battery you shouldn’t try getting 500 watt from 12 V, if you do, you will end up destroying your battery in sometime. With 1200 watt your will destroy your battery in minutes or seconds.

      But with Li-ion it is easily possible.

      Reply
      • Ramaiah Thambi says

        Thank you very much.

        Reply
      • Ramaiah Thambi says

        Can I parallel batteries then?

        Reply
        • Swagatam says

          yes you can use batteries in parallel

          Reply
      • MANJUNATH says

        Sir You have computer ups 500VA OR 600VA CIRCUIT DIAGRAM

        Reply
        • Swagatam says

          Manjunath, sorry I do not have this circuit at this moment.

          Reply
  11. Ramaiah Thambi says

    Can I use a 100Ah inverter battery?

    Reply
    • Swagatam says

      with a 12V battery 100 ah will not produce 500 watts.

      Reply
      • shankar says

        but why sir ,VxI = 1200w theortically, but does it depends on effeciency and pf of inverter circuit.
        a new 12v 7.2Ah vrla battery does not provide enough power, my 5w ac led bulb running for 1-.5hr and battery voltage goes from 13.2v to10.7. ,
        kindly provide exact detail for 200w with required battery ah rating. lead acid

        Reply
        • Swagatam says

          It is because Lead acid batteries are not designed to be discharged at their full Ah rate, they must be discharged at 10% or maximum 20 % of their Ah rate.

          You can get more info on this here

          Lead Acid Battery Charger Circuits

          Reply
        • Laundrel says

          Can I use 9V battery?

          Reply
          • Swagatam says

            No!

            Reply
  12. Ram says

    Note: sorry i posted this query in wrong topic before so posting here

    Hi Sir,

    Need your help again. You are very knowledgeable and humble person. This earth needs more like you.

    Can u tell how we can check efficiency of inverter in general understanding language without going into theory behind it. I m asking for the reason bcoz i have very old 3055 based desi inverter of 500 watt and it running excellent since 2003. Only thing is missing is battery overcharge protection but most of the time charging renaming off bcoz i have sukam mppt solar charge controller of 17amp with 300w solar panel. I do not want to upgrade it to digital microcontroller based only fur the reason old inverter never gone bad in 17 years. Only problem in these years that i had to re solder wires to some led and amp meter one time only. Please suggest ur valuable input wheather its worth to upgrade it with latest technology digital inverter…
    Images
    https://1drv.ms/u/s!AkqDWegCTCgviUoXPcC6pEByP6rt?e=H77KIy

    And one more question what is the best charging current practice ( at always 10% of battery capacity or can use low charging current. I think slow charging increase the battery life and so i use 5-7amp current only..) in case if powercut is about an hour in 24 hour. Battery i have is microteck 150ah. I understand u will be very busy but will feel happy if u reply with ur valuable input.

    Reply
    • Swagatam says

      Thanks Ram, you can check the efficiency by measuring and comparing the V x I of the input 12V supply side of the inverter and V x I of the output 220V side of the inverter.
      Best charging current for all lead acid battery is 10%, reducing below this level is not necessary as it may increase the charging time to 20 hours. But yes it will help to increase the life of the battery.

      for auto cut off at 14.2V you can try the following circuit
      inverter battery auto cut off

      Reply
      • Ram says

        Thank you 🙂

        Reply
  13. Sidaray says

    Hi Sir, It’s awesome explanation but I need to know, How we will come to know whether battery charged fully, Is there any led indication?
    Thanks
    Sidaray

    Reply
    • Swagatam says

      Thanks Sidaray, the simplest way is to add an ammeter in series with the battery positive, when the needle nears the zero volt, it will indicate the battery is fully charged.

      Reply
  14. Eric maduku says

    Thanks for your good works. Can I add more 3205 mosfets for greater wattage? Thanks

    Reply
    • Swagatam says

      yes you can, it is the MOSFETs, the battery and the transformer that decide the power output.

      Reply
  15. Sreenivasulu Dammu says

    swagatam sir i want 12v dc 1000w or 1200w power inverter ckt diagrams.

    Reply
    • Swagatam says

      Sree, you can try any inverter design from this website, and upgrade it as per the details presented in this article:

      https://www.homemade-circuits.com/upgrading-low-power-inverter-to-high/

      Reply
  16. Techcrazy55 says

    Very clean and straight forward project i would like to design, But then how can i add an overload protection to practically work wit this project, Thanks Swagatam.

    Reply
    • Swagatam says

      Thank you, you can add the following concept for overload protection:

      https://www.homemade-circuits.com/low-battery-cut-off-and-overload/

      Reply
  17. K GOPI SANKAR says

    Thank you so so much for your reply sir.. Have to finally get a jem in electronic field who solves the problems with efficiency..

    Reply
    • Swagatam says

      You are welcome KGopi

      Reply
  18. Akande says

    Please I need answers because I wanna couple a 130w solar panel with 650VA UPS, will this work sir

    Reply
  19. Amar says

    I have request to you sir, pls upload configuration and design of current source inverter

    Reply
    • Swagatam says

      Thank you Amar, I am studying it, and if possible I’ll post a related article soon.

      Reply
      • K GOPI SANKAR says

        Sir i have 3kw /400v Dc on-grid Solar system… when grid power switches off during peak hours of sunshine ongrid solar also switches off.. so energy from solar system getting wasted…so during this switched off time can we have another solar inverter without battery system to run atleast 2000w power system.. Night i don’t need power

        Reply
        • Swagatam says

          Yes you can use the solar power by diverting it through a relay changeover. This relay should be powered from grid voltage, so while grid is available, the relay contacts keep the external inverter disconnected from the solar power. When the grid fails, the relay contacts switch over and connect the external inverter with the solar panel.

          Reply
          • K GOPI SANKAR says

            Thank you somuch for your Replay Sir.. without battery can i use solar energy directly .. just by converting to 220v AC from 3kw..400v DC

            Reply
            • Swagatam says

              Hi K Gopi, yes that may be possible if the transformer is correctly designed for converting the 400 V into 220 V

  20. Noel says

    Hi
    I need a protection circuit that will keep an appliance switched off during load shedding and only switch on when the power comes back on and is stable at 240v.
    Kind regards.

    Reply
    • Swagatam says

      Hi, you can try the concept presented in the following article

      https://www.homemade-circuits.com/mains-high-low-voltage-protection/

      Reply
      • Noel says

        Hi
        Thanks for the reply appreciate it. Our line voltage is 240v and when we have load shedding it switches back on with over 300v. I need a circuit that will switch the appliances back on when the voltage stabilizes at 240v.
        Regards

        Reply
        • Swagatam says

          Hi, the linked circuit will do exactly that! It will never switch ON the appliance with the wrong voltage

          Reply
  21. yusuf-freeman abdussalam says

    good evening sir,i would like to know the formulas for calculating ic 4047 frequency

    Reply
    • Swagatam says

      Yusuf, you can refer to this article:

      https://www.homemade-circuits.com/ic-4047-datasheet-pinouts-application/

      Reply
  22. lloydcruspero says

    hi sir, can you help me how to make a 500 watts inverter, 12v DC to 220v AC, 60H, and modified square waves? can you make a circuit for me and its layout on pcb?

    Reply
    • Swagatam says

      Hi lloyd, you can try the following concept

      https://www.homemade-circuits.com/1500-watt-pwm-sinewave-inverter-circuit/

      Reply
  23. Evans mworeh says

    Hi engineers,I have done this project is good,I even went further ahead by making it an automatic inverter charger. My problem is that my batteries don’t get charged fully since inverters with pwm usually have their transformer voltages halved or 2/3 of the same,any help on how I can improve the charging speed will be appreciated.

    Reply
    • Swagatam says

      Thank you Evans, I have already addressed this issue in the article, under battery MOSFET, transformer selection….

      Reply
  24. Bios says

    Hello Sir I have 7805ic and IRF 540 mosfet can I use it to make this inverter?

    Reply
    • Swagatam says

      Bios, 7805 will not work, you will have to use 7812, IRF540 can be tried, it might work, but mount them on large heatsinks

      Reply
  25. Loydiel says

    can I have the layout in Pcb of the modified sine wave inverter circuit?
    and what is the orange one in the circuit represents?

    Reply
  26. Martin says

    I’ve been looking at various inverter circuit designs on the ‘net and youtube. You have done a very good job explaining your circuits and detailing how they work. As you know power inverters can be pricey for anything 500 watts and above, so your designs now seem obtainable to actually making my own.
    What would be required to build a 2000w or 5000w power inverters? Does your circuit design change?
    How would you go about calculating the components specs for a these higher wattage inverters?
    Thank you for posting your circuits and your comprehensive yet well written explanation.
    -Martin

    Reply
    • Swagatam says

      Glad you liked it, I have explained the process of calculating the transformer and the MOSfET for upgrading the inverter to any desired power level.

      Reply
  27. Andrew says

    I really appreciate this effort.
    Am new in this website and am always looking forward to understanding how a smps circuit oscillates, cause am a 17yr old beginner in electronics

    Reply
    • Swagatam says

      Thank you, I appreciate your interest…keep up the good work

      Reply
  28. Andrew says

    excellent design

    Reply
  29. Evans says

    Hi,I like the design. What can be done to the circuit so that I can use a two wire transformer at the primary side and also instead of using the relays I just use the same mosfets for inverter and battery charging? I’ll appreciate a schematic diagram if possible.

    Reply
    • Swagatam says

      Hi, I’ll try to update it soon

      Reply
      • Evans says

        Will appreciate

        Reply
      • Evans mworeh says

        Hello sir swagatam,how did it go,did you find anything good for an update about an inverter circuit diagram using a transformer without centre tap?

        Reply
        • Swagatam says

          Hi Evans, I have updated a full bridge version at the end of the post. You can check it out…

          Reply
          • Amar says

            Sir pls upload current source inverter circuit and design configuration of it.

            Reply
            • Swagatam says

              I will surely try…

          • Evans mworeh says

            Thank you sir for your kindness,now my other questions are;
            1. Can we use N channel mosfets only with the same circuit,any update please? Coz with high currents, I will be forced to use a big number of p channel mosfets which Leeds to high cost and space limitations.
            2. What could be the current ratings of RL 2 & RL 3 if for instance I built a 24vdc/220vac/6000w inverter?

            Reply
            • Swagatam says

              Evans, N-channel cannot be used without specialized ICs or a bootstrapping network

            • Evans mworeh says

              Thank you sir for your response. So if I integrate a boostraping network then can use cd4047 as the oscillator? True or not? Any clarifications?

            • Swagatam says

              It is possible with bootstrapping introduced with any oscillator.

            • Evans mworeh says

              Sorry had a typing error,I meant cd4047

  30. Vikram says

    Is 24v battery is available

    Reply
  31. Juan Carlos Bonavota says

    I liked the circuit. I only wish it had a power supply for its regulation both in frequency and in output voltage. Thank you very much

    Reply
    • Swagatam says

      Thank you, if possible I’ll try to update the details in the article.

      Reply


  32. COMMENT BOX IS MOVED AT THE TOP


Primary Sidebar

Electronic Projects Categories

  • 3-Phase Power (15)
  • 324 IC Circuits (19)
  • 4017 IC Circuits (51)
  • 4060 IC Circuits (25)
  • 555 IC Circuits (92)
  • 741 IC Circuits (18)
  • Amplifiers (48)
  • Arduino Engineering Projects (82)
  • Audio Projects (83)
  • Battery Chargers (75)
  • Car and Motorcycle (87)
  • Datasheets (44)
  • Decorative Lighting (Diwali, Christmas) (31)
  • DIY LED Projects (81)
  • Electronic Components (96)
  • Electronic Devices and Circuit Theory (34)
  • Electronics Tutorial (99)
  • Fish Aquarium (5)
  • Free Energy (34)
  • Games (2)
  • GSM Projects (9)
  • Health Related (16)
  • Heater Controllers (23)
  • Home Electrical Circuits (98)
  • Incubator Related (6)
  • Industrial Electronics (25)
  • Infrared (IR) (39)
  • Inverter Circuits (93)
  • Laser Projects (10)
  • LM317/LM338 (21)
  • LM3915 IC (24)
  • Meters and Testers (52)
  • Mini Projects (152)
  • Motor Controller (64)
  • MPPT (7)
  • Oscillator Circuits (12)
  • PIR (Passive Infrared) (8)
  • Power Electronics (32)
  • Power Supply Circuits (64)
  • Radio Circuits (9)
  • Remote Control (46)
  • Security and Alarm (54)
  • Sensors and Detectors (114)
  • SG3525 IC (4)
  • Simple Circuits (72)
  • SMPS (30)
  • Solar Controllers (60)
  • Timer and Delay Relay (51)
  • TL494 IC (5)
  • Transformerless Power Supply (8)
  • Transmitter Circuits (36)
  • Ultrasonic Projects (12)
  • Water Level Controller (45)

Follow Homemade Circuits

Facebook
Twitter
YouTube
Instagram
My Facebook-Page
Quora

Feeds

Post RSS
Comment RSS

Circuit Calculators

  • AWG to Millimeter Converter
  • Battery Back up Time Calculator
  • Capacitance Reactance Calculator
  • IC 555 Astable Calculator
  • IC 555 Monostable Calculator
  • Inductance Calculator
  • LC Resonance Calculator
  • LM317, LM338, LM396 Calculator
  • Ohm’s Law Calculator
  • Phase Angle Phase Shift Calculator
  • Power Factor (PF) Calculator
  • Reactance Calculator
  • Small Signal Transistor(BJT) and Diode Quick Datasheet
  • Transistor Astable Calculator
  • Transistor base Resistor Calculator
  • Voltage Divider Calculator
  • Wire Current Calculator
  • Zener Diode Calculator

© 2021 · Swagatam Innovations

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.Ok