A very simple low battery cut-off and overload protection circuit has been explained here.

Table of Contents
  • How it Works
    • Parts List
  • Formulas and Calculations
  • Inverter Overload Cut-OFF using Opamp
    • How it Works
    • Formulas and Calculations

The figure shows a very simple circuit set up which performs the function of an overload sensor and also as an under voltage detector.

In both the cases the circuit trips the relay for protecting the output under the above conditions.

How it Works

Transistor T1 is wired as a current sensor, where the resistor R1 forms the current to voltage converter.

The battery voltage has to pass through R1 before reaching the load at the output and therefore the current passing through it is proportionately transformed into voltage across it.

This voltage when crosses the 0.6V mark, triggers T1 into conduction.

The conduction of T1 grounds the base of T2 which gets immediately switched Off. The relay is also consequently switched OFF and so is the load.

T1 thus takes care of the over load and short circuit conditions.

Transistor T2 has been introduced for responding to T1's actions and also for detecting low voltage conditions.

When the battery voltage falls beyond a certain low voltage threshold, the base current of T2 becomes sufficiently low such that it's no longer able to hold the relay into conduction and switches it OFF and also the load.

Low Battery and Overload Protection Circuit for Inverters

The"LOAD" terminals in the above diagram is supposed to be connected with the inverter +/- supply terminals.

This implies that the battery current from the right side has to pass through R1 before reaching the inverter, enabling the sensing circuit around R1 to sense a possible over current or overload situation.

CORRECTION:

The above shown circuit will not initiate unless the relay is actuated manually through a push switch as shown below:

Low Battery and Overload Protection Circuit for Inverters with push button start

Parts List

  • R1 = 0.6/Trip Current
  • R2 = 100 Ohms,
  • R3 =10k
  • R4 = 100K,
  • P1 = 10K PRESET
  • C1 = 100uF/25V
  • T1, T2 = BC547,
  • Diodes = 1N4148
  • Relay = As per the specs of the requirement.

Formulas and Calculations

Low Battery Cut-off Threshold

The low battery sensing is handled by R3 and P1 which forms a potential divider to set the base voltage of the relay driver transistor (T2). When the battery voltage drops below a set threshold the voltage at the base of T2 falls below Vbe (0.6V–0.7V) turning OFF the relay and disconnecting the load.

Formula for Threshold Voltage:

Vth = Vbat * (P1 / (P1 + R3))

  • Where:
  • Vth = Base threshold voltage (0.6V–0.7V)
  • Vbat = Battery voltage
  • P1 = Adjustable potentiometer resistance
  • R3 = Fixed resistor

To calculate the battery voltage cut-off level:

Rearrange for Vbat:

Vbat = Vth * (P1 + R3) / P1

Overload/Overcurrent Sensing

Overcurrent protection is implemented using R1 which is placed between the base and emitter of transistor T1.

As the load current increases, the voltage drop across R1 rises. When the voltage across R1 reaches the Vbe of T1 (typically 0.6V–0.7V) T1 starts conducting and shunts the base current of T2 turning it OFF.

Formula for Overcurrent Trip Current:

Itrip = Vbe / R1

  • Where:
  • Itrip = Overcurrent trip current
  • Vbe = Base-emitter threshold voltage of T1 (0.6V–0.7V)
  • R1 = Resistor sensing the overcurrent

Base Current Limiting Resistor (R2)

Resistor R2 (optional) limits the base current for T1 to prevent excessive current through its base-emitter junction.

Formula for Base Resistor (if used):

R2 = (Vbat - Vbe) / Ib

  • Where:
  • Ib = Required base current for T1
  • Vbat = Battery voltage
  • Vbe = Base-emitter voltage of T1

For small signal transistors (e.g., BC547) Ib can be estimated as Iload / hFE where hFE is the DC current gain.

Inverter Overload Cut-OFF using Opamp

In the above paragraphs I have explained a very simple concept of inverter overload cut-off using only transistors.

However a cut off system using only transistors cannot be very accurate and sharp.

In order to get a precision inverter overload and short circuit cut off circuit the use of an opamp based design becomes imperative.

The following diagram shows a simple battery overload controller circuit using a single opamp 741 and a relay driver stage.

Inverter Overload Cut-OFF circuit

How it Works

The opamp is configured as a simple comparator circuit. he inverting input of the opamp is clamped at a fixed 0.6 V using a 1N4148 diode.

The non-inverting input of the op amp is connected with the negative line of the circuit through a over-current sensor resistor Rx.

Due to inverter overload or short circuit or over current conditions, a voltage drop develops across the resistor Rx which can exceed the 0.6V as per the calculated value of the RX, and cause the non-inverting input of the opamp potential to go higher then its inverter 0.6V potential.

This causes the op amp output to turn high activating the transistors and tripping the relay.

When power is first switched ON, and assuming the inverter is working normally without an overload, the voltage developed across RX is minimal, which keeps the pin3 potential of the opamp the opamp lower than the pin2 potential.

This allows the output of the opamp to be low ensuring that the transistor is switched OFF, and relay contacts stays at the N/C point.

Due to this the 12V is able to reach the inverter and operate it normally.

However, as soon as an overload or over current happens at the inverter side, a large amount of current passes through the RX resistor, causing a voltage drop to develop across pin3 of the IC.

When this voltage drop exceeds the 0.6V reference level of the pin2 of the IC, the output of the op amp goes high, causing the transistor to switch ON and trigger the relay.

The relay contacts now shift from N/C to N/O switching of power to the inverter and thereby averting the short circuit or overload conditions.

The N/O contact can be seen attached with the base of the relay driver transistor, which ensures that as soon as the an overload is detected the relay contact quickly latches the transistor, switching the power permanently off for the inverter.

The power can be restored only by disconnecting the 12 V battery input, but before that it must be ensured that the short circuit or the over load condition is appropriately removed from the inverter side.

Formulas and Calculations

Key Parameters

  • RX: Current sensing resistor (ohms)
  • Vref: Reference voltage at the inverting input (-) of IC741
  • Itrip: Overcurrent trip current (amperes)
  • Vdrop: Voltage drop across RX at trip current

Formulas

Voltage Drop Across RX:

Vdrop = Itrip * RX

  • Where:
  • Itrip = Overcurrent trip point (A)
  • RX = Current sensing resistor (ohms)

Reference Voltage (Vref):

The voltage at the non-inverting input (+) of IC741 is set using a resistor divider or Zener diode (if used). For proper cutoff:

Vref ≈ Vdrop

Choosing RX (Sensing Resistor):

To calculate the value of RX for a given trip current:

RX = Vref / Itrip

  • Where:
  • Vref = Reference voltage (V)
  • Itrip = Desired trip current (A)

Power Dissipation in RX:

The sensing resistor RX must handle the power dissipated during operation.

We will Use:

P = Itrip2 * RX

  • Where:
  • P = Power dissipation in RX (W)

Choose RX with a power rating higher than P for safe operation.

Example Calculation

Let’s assume:

Itrip = 10A (trip current)

Vref = 0.7V (reference voltage determined by the op-amp threshold)

Step 1: Calculate RX

RX = Vref / Itrip = 0.7 / 10 = 0.07 ohms

Step 2: Power Dissipation in RX

P = Itrip2 * RX = 102 * 0.07 = 7W

Choose a 0.07-ohm 10W resistor for RX to ensure safe operation.

You'll also like:

  • How to Add Adjustable Current and Voltage feedback Control to SG3525 Inverters
  • How to Build a 400 Watt High Power Inverter Circuit
  • Dual A/C Relay Changeover Circuit
  • convert h bridge to sine wave h bridge basic layoutConvert any H-Bridge Inverter to Sine Wave H-bridge Inverter

Filed Under: Inverter Circuits Tagged With: Battery, Inverters, Overload, Protection

About Swagatam

I am an electronics engineer and doing practical hands-on work from more than 15 years now. Building real circuits, testing them and also making PCB layouts by myself. I really love doing all these things like inventing something new, designing electronics and also helping other people like hobby guys who want to make their own cool circuits at home.

And that is the main reason why I started this website homemade-circuits.com, to share different types of circuit ideas..

If you are having any kind of doubt or question related to circuits then just write down your question in the comment box below, I am like always checking, so I guarantee I will reply you for sure!



Previous Post: « Make This 1KVA (1000 watts) Pure Sine Wave Inverter Circuit
Next Post: Cheapest SMPS Circuit Using MJE13005 »

Reader Interactions

Questions & Answers

Total Posts: 254
Newest Oldest
Asikpo Okon
September 12, 2025 • 11 months ago #185203

pls sir can help with your email or link I can use and send an image to, I have this variable power supply circuit but I want you to help preview it if there’s any error. before implement the circuit or budget for it

Reply
SwagatamAdmin
September 12, 2025 • 11 months ago #185206

Hi Okon, please upload it to your google drive and provide the “shared” link to me and I will check it out.
But please, for a power supply related article, please post it under a power supply related article…

Reply
abdulkareem
April 3, 2025 • 1 year ago #171393

sir how are you
I make construction inverter using sg3525 mosfet 4 ups transformer I tested output 473v AC
how decrease. voltage to 220

Reply
SwagatamAdmin
April 3, 2025 • 1 year ago #171397

Abdulkareem,
It means, the transformer winding ratio is not suitable for 220V AC output, please change the secondary number of turns to get 250V, instead of such high value…

Reply
Hillary
February 4, 2025 • 1 year ago #168280

Good day sir, thank you for all your good works here. You have really helped so many especially me. More grease to your elbow.
I made an automatic low battery cut off circuit but it comes back on immediately the battery voltage increases above the cutoff level. Please help me with a circuit that will keep the Auto low battery cut off inactive until a preset button is pressed

Reply
SwagatamAdmin
February 4, 2025 • 1 year ago #168282

You are welcome Hillary,
In your existing circuit please connect a high value resistor between 10k and 100k, between the N/C contact of the relay and the base of the relay driver transistor. Next, attach a push-button between emitter/collector of the transistor for the resetting the action.

Reply
Hillary
February 4, 2025 • 1 year ago #168284

I have done it but when an inductive load is connected to the inverter, the relay flickers

Reply
SwagatamAdmin
February 4, 2025 • 1 year ago #168286

To control relay flickering, just connect a 220uF or a 470uF capacitor across the relay coil, make sure to connect it with correct polarity.

Reply
Murat bayındır
December 28, 2024 • 2 years ago #167594

Düşük voltaj kesme devresinde role yerine paralel bağlı mosfetler kullanılabilir mi teşekkür ederim.

Reply
Hillary
December 18, 2024 • 2 years ago #167419

Good day sir, I made the battery low cut off and it works fine but then, when the circuit is activated at 10.5v, it automatically deactivates itself when the voltage goes back to 10.7v and this continues. So I want to ask if there is any other circuit to add to keep it activated until a reset button is pressed?

Reply
SwagatamAdmin
December 18, 2024 • 2 years ago #167423

Hillary, which circuit are you using? It can be be latched using an SCR stage. Let me know which circuit are you using, I will try to modify it accordingly.

Reply
Hillary
December 18, 2024 • 2 years ago #167426

I am using Opamp circuit

Reply
SwagatamAdmin
December 18, 2024 • 2 years ago #167427

The opamp circuit is not a low battery cut off circuit, it is an overcurrent/overload cut-off circuit, and it has a latching feature already.

Reply
Ibrahim musa wakili
December 3, 2024 • 2 years ago #166483

how can I determine the Rx

Reply
SwagatamAdmin
December 3, 2024 • 2 years ago #166501

RX = 0.7 / Maximum inverter current limit

Reply
chuks
July 12, 2024 • 2 years ago #154434

how do i calculate the over load current of 1KVA inverter

Reply
SwagatamAdmin
July 13, 2024 • 2 years ago #154543

Simply divide 1kva (1000 watts approx) with your battery voltage.

Reply
Hillary
April 9, 2024 • 2 years ago #151441

Good evening sir, please what value of shunt resistor can be used for 1000w inverter

Reply
SwagatamAdmin
April 9, 2024 • 2 years ago #151448

Hi Hillary, Please provide the inverter operating voltage value.

Reply
Hillary
December 18, 2024 • 2 years ago #167418

The battery voltage is 12v

Reply
Yahya
December 5, 2023 • 3 years ago #147739

Hello, I have a question: Does the second circuit work as a short circuit protection at any point in the inverter?

Reply
SwagatamAdmin
December 5, 2023 • 3 years ago #147740

Yes, it will work as a short circuit and overload cut off circuit.

Reply
Raed
November 21, 2023 • 3 years ago #147218

Is it possible to use N-MOS instead of BC547 transistor?

Reply
SwagatamAdmin
November 21, 2023 • 3 years ago #147221

Sorry, no, only NPN BJTs are recommended.

Reply
Segun
October 23, 2023 • 3 years ago #146424

Please what is the RX resistor

Reply
SwagatamAdmin
October 23, 2023 • 3 years ago #146425

RX = 0.7 / Max over load current

Reply
Michael Ojobi
October 6, 2023 • 3 years ago #145909

I have not yet work on the circuit but, I understand it very well sir. Sir! Is there a way that I use same transformer for both inverter and charger?

Reply
SwagatamAdmin
October 6, 2023 • 3 years ago #145913

I wouldn’t recommend using a single transformer for both charging and the inverter as that can make the configuration too messy and difficult to optimize. Still, if you are willing to give it a try you can consider the following article:

https://www.homemade-circuits.com/single-transformer-inverterchargerchang/

Reply
Michael Ojobi
October 6, 2023 • 3 years ago #145885

Thank you so much sir, I love that circuit that have low voltage protection and charger, it will be very good for inverter. Thanks sir

Reply
Michael
October 8, 2023 • 3 years ago #145998

Hello sir, if I use small transformer 220v to 12v for bridging diode to charger oscillation and use 30ahs relay for the charging output, will I have high current to charge battery?

Reply
SwagatamAdmin
October 8, 2023 • 3 years ago #146010

The output current depends on the transformer current, so the transformer current must be according to the battery requirements.

Reply
SwagatamAdmin
October 6, 2023 • 3 years ago #145902

You are welcome Michael, I hope you are able to build it successfully.

Reply
Michael Ojobi
October 5, 2023 • 3 years ago #145847

Okay sir, but how can I get accurate circuit for low voltage protection and over load protection

Reply
SwagatamAdmin
October 5, 2023 • 3 years ago #145848

Michael, You can try the second design from the following article. Just make sure to make two changes. 1) Swap the pin2 and pin3 with each other. 2) Replace the “charging voltage input” with Inverter supply +/- inputs.
https://www.homemade-circuits.com/how-to-make-simple-low-battery-voltage/

Reply
Michael Ojobi
October 5, 2023 • 3 years ago #145845

Yes, the one I used was that op amp circuit but ic is lm358 which didn’t cut off voltage at 10.4v,

Reply
SwagatamAdmin
October 5, 2023 • 3 years ago #145846

The op amp circuit is an overload cut off circuit, it is not a low voltage cut off circuit.

Reply
Michael Ojobi
October 4, 2023 • 3 years ago #145810

Thank you for the clarification, I have did it in project board but didn’t cut off when the battery is low at 10.4v

Reply
SwagatamAdmin
October 5, 2023 • 3 years ago #145840

The transistor circuit cannot be very accurate, if you need more accuracy you may have to use an op amp circuit.

Reply
Michael Ojobi
October 4, 2023 • 3 years ago #145793

But what I mean before is, the ic lm358 have two output at pin 1 and pin 7, so it’s only one section I will use?

Reply
SwagatamAdmin
October 4, 2023 • 3 years ago #145795

Yes that is correct, you will have to use only one op amp among the two!

Reply
Michael Ojobi
October 4, 2023 • 3 years ago #145792

Okay, thank you sir

Reply
Michael Ojobi
October 4, 2023 • 3 years ago #145784

Thanks for your quick response sir, but
the lm358 which you said I should how dual output, is it one of the output I need? Please help me with the circuit sir

Reply
SwagatamAdmin
October 4, 2023 • 3 years ago #145789

Sorry, I cannot understand your question, what is the need of a dual output? the 741 circuit uses a relay for the cut off.

Reply
Michael
October 3, 2023 • 3 years ago #145739

Can I use same circuit for 24v inverter

Reply
SwagatamAdmin
October 3, 2023 • 3 years ago #145744

Yes, but replace the relay with a 24V relay and for the op amp circuit replace the 741 with LM358 op amp.

Reply
View Older Comments

Need Help? Please Leave a Comment! We value your input—Kindly keep it relevant to the above topic! Cancel reply

Your email address will not be published. Required fields are marked *

Primary Sidebar



Categories

  • Arduino Projects (95)
  • Audio and Amplifier Projects (134)
  • Automation Projects (18)
  • Automobile Electronics (103)
  • Battery Charger Circuits (89)
  • Datasheets and Components (109)
  • Electronics Theory (150)
  • Energy from Magnets and Earth (40)
  • Games and Sports Projects (11)
  • Grid and 3-Phase (20)
  • Health related Projects (27)
  • Home Electrical Circuits (13)
  • Indicator Circuits (16)
  • Inverter Circuits (100)
  • Lamps and Lights (163)
  • Meters and Testers (72)
  • Mini Projects (28)
  • Motor Controller (68)
  • Oscillator Circuits (30)
  • Pets and Pests (15)
  • Power Supply Circuits (91)
  • Remote Control Circuits (50)
  • Security and Alarm (65)
  • Sensors and Detectors (107)
  • SMPS and Converters (46)
  • Solar Controller Circuits (62)
  • Temperature Controllers (44)
  • Timer and Delay Relay (50)
  • Voltage Control and Protection (44)
  • Water Controller (37)
  • Wireless Circuits (31)



Circuit Simulator

circuit simulator image



Subscribe to get New Circuits in your Email



Other Links

  • Privacy Policy
  • Cookie Policy
  • Disclaimer
  • Copyright
  • Videos
  • Sitemap

People also Search

555 Circuits | 741 Circuits | LM324 Circuits | LM338 Circuits | 4017 Circuits | Ultrasonic Projects | SMPS Projects | Christmas Projects | MOSFETs | Radio Circuits | Laser Circuits | PIR Projects |



Recent Comments

  • Swagatam on 2 Cool 50 Watt Inverter Circuits for Students and Hobbyists
  • Swagatam on The Perfect FM Radio Circuit using TDA7000 IC
  • Swagatam on 9 Simple Sine Wave Generator Circuits Explored
  • way on 2 Cool 50 Watt Inverter Circuits for Students and Hobbyists
  • Athull on The Perfect FM Radio Circuit using TDA7000 IC

Social Profiles

  • Twitter
  • YouTube
  • Instagram
  • Pinterest
  • My Facebook-Page
  • Stack Exchange
  • Linkedin

© 2026 · Swagatam Innovations