• Skip to main content
  • Skip to primary sidebar

Homemade Circuit Projects

Need circuit help? Post them in the comments! I've answered over 50,000!

Blog | Categories | About | Hire Me | Contact | Calculators-online
You are here: Home / Oscillator Circuits / 3-Phase Signal Generator Circuit using Opamp

3-Phase Signal Generator Circuit using Opamp

Last Updated on January 8, 2024 by Swagatam 116 Comments

Many a times we find it crucial and handy to possess a true three phase signal for evaluating many different electronic configurations such three phase inverters, three phase motors, converters etc.

Table of Contents
  • Circuit Operation
    • Circuit Diagram
      • Parts List

Since it's not so easy to incorporate single phase to three phase conversion quickly we find this particular implementation difficult to acquire and enforce. The proposed circuit enables the above discussed well calculated spaced and positioned sine waves outputs to be generated from a single master input source.

Circuit Operation

The circuit functioning of the three phase waveform generator circuit may be understood with the help of the following explanation:

An input sine sample waveform is fed across the point "input" and ground of the circuit.This input signal gets inverted and buffered by the unity gain opamp A1. This inverted and buffered signal acquired at the output of A1 now becomes the new master signal for the forthcoming processing.

The above buffered master signal gets once again inverted and buffered by the next unity gain opamp A2 creating an output with zero degree initial phase across the points "Phase1"

Simultaneously, the master signal from A1 output is phase shifted by 60 degrees via the RC network R1, C1, and fed to the input of A4.

A4 is set up as a non-inverting opamp with a gain of 2 in order to make up for the signal-loss in the RC configuration.

On account of the fact that the master signal is phase shifted 180 degrees from the input signal, and further shifted to an additional 60 degrees by the RC network, the ultimate output waveform gets shifted by 240 degrees, and constitutes the "Phase3" signal.

Now, the next unity gain amp A3 sums up the A1 output (0 degrees) with A4 output (240 degrees), creating a 300 degree phase shifted signal at its pin#9, which is in turn inverted appropriately, shifting the phase to an extra 180 degrees, creating the intended 120 degree phase signal across its output indicated as "Phase2".

The circuit is intentionally wired up to work with a fixed frequency in order to yield better accuracy.

Fixed values are used for R1 and C1  for rendering the intended, accurate 60 degree phase shifts.

For specific customized frequencies, you may use the following formula:

R1 = (√3 x 10^6) / (2π x F x C)

R1 = (1.732 x 10^6) / (6.28 x F x C1)

where:
R1 is in kohms
C1 is in uf

Circuit Diagram

Parts List

All R = 10 kohms
A1---A4 = LM324
Supply = +/- 12vdc

Frequency (hz)R1 (kohms)C1 (nf)
10002.7100
4006.8100
604.71000
505.61000

The above design was investigated by Mr. Abu-Hafss and appropriately corrected for obtaining legitimate responses from the circuit, the following images provide a detailed info regarding the same:

Feedback from Mr. Abu-Hafss:

I needed a 15VAC 3-phase supply to test 3-phase rectifiers. I simulated this circuit the other day but failed to get proper results. Today, I made it work.

IC A2 and resistors connected to pin 6 could be eliminated. The resistor between pin 7 and 9 could be connected between the main input and pin 9. Phase-1 output can be collected from the original AC input. Phase 2 and 3 can be collected as indicated in the circuit.

However, my actual requirement could not be fulfilled. When these 3 phases are connected to a 3-phase rectifier, the wave form of phase 2 and 3 gets disturbed. I tried with the original circuit, in that case all three phases gets disturbed

Finally got a solution! A 100nF capacitor connected in series with each phase and the rectifier solved the problem to a great extent.

Though the rectified output is not consistent but, it is quite acceptable

Update: The following image shows a much simpler alternative for generating 3 phase signals with accuracy and without complicated adjustments:

You'll also like:

  • UJT Pulse Generator10 Simple Unijunction Transistor (UJT) Circuit Diagrams Explained
  • C22 Simple Voltage to Frequency Converter Circuits Explained
  • colpitts crystal oscillatorUnderstanding Crystal Oscillator Circuits
  • sine cosine generator circuitSine-Cosine Waveform Generator Circuit

Filed Under: Oscillator Circuits Tagged With: Generator, Opamp, Phase, Signal

About Swagatam

I am an electronics engineer and doing practical hands-on work from more than 15 years now. Building real circuits, testing them and also making PCB layouts by myself. I really love doing all these things like inventing something new, designing electronics and also helping other people like hobby guys who want to make their own cool circuits at home.

And that is the main reason why I started this website homemade-circuits.com, to share different types of circuit ideas..

If you are having any kind of doubt or question related to circuits then just write down your question in the comment box below, I am like always checking, so I guarantee I will reply you for sure!



Previous Post: « Homemade Inductance Meter Circuit
Next Post: Half-Bridge Mosfet Driver IC IRS2153(1)D Datasheet »

Reader Interactions

Questions & Answers

Total Posts: 116
Newest Oldest
musa kizito
September 5, 2013 • 13 years ago #14933

You are really helping . sir, Is it possible to convert car alternator to dc motor without PIC? if yes, I need your help on the circuitry. thank you

Reply
SwagatamAdmin
September 5, 2013 • 13 years ago #14943

Thanks Musa, it is possible but it could be a mechanical concept, not within my expertise.

Reply
musa kizito
September 5, 2013 • 13 years ago #14950

Thank you for the quick reply. I am a proud member of this blog. I can not wait to see the day passing without me visiting this site. I will try the mechanical concept, for the convertion of a car alternator to dc motor. Thank you once again.

Reply
SwagatamAdmin
September 6, 2013 • 13 years ago #14963

You are welcome Musa, I appreciate your interest.

Reply
edalcor zuproc
September 8, 2013 • 13 years ago #15013

hi sir good day. I'm here again. i have a 3 phase genset(standby generator} i think it was rated 1.5-2kw 440v. My problem is i only need is 1 phase 220v output for my needs can you help me design a circuit to make it 1 phase output. Thank you for your effort of doing this.

Reply
SwagatamAdmin
September 9, 2013 • 13 years ago #15038

Hi Edalcore,

I am sorry I don't any verified approach to do this, so it might be dangerous to suggest something which hasn't been confirmed by me.

Reply
Muhammad Junaid
September 15, 2013 • 13 years ago #15275

Dear edalcor zuproc!
It is possible but only by using a transformer, if your generator has DELTA output, you would require a Delta-Wye Connection three phase transformer with a common neutral on its output to use it for single phase.. (Verified Method)
You may ask for its calculations if you want to design it..!

Reply
Muhammad Junaid
September 15, 2013 • 13 years ago #15276

Hello Swagatam Majumdar…!
I need your kind help please, can you please provide me a frequency converter circuit to convert 220V 50 Hz to 220V 60 Hz for a load of about 5A at 220V using oscillations or any other method using MOSFETS or IGBT's…. please help me regarding this…!!!
plz plz

Reply
SwagatamAdmin
September 15, 2013 • 13 years ago #15306

Hello Muhammad Junaid,

VFD is a very complex circuit, so I don't think it would be possible for me, I'll try though, if I succeed then will surely post it for you.

Reply
SwagatamAdmin
September 15, 2013 • 13 years ago #15307

..a single phase VFD looks slightly easier, I'll try to do it…let's be hopeful

Reply
Palo Kubik
December 28, 2013 • 13 years ago #18596

220V 50 Hz to 220V 60 Hz i would say just make from 220 AC –220 DC and after make half bridge mosfet or igbt pulsing on 60 Hz

Reply
Palo Kubik
December 28, 2013 • 13 years ago #18597

use 3 phase rectifier and after let it pulsing on halfbridge mosfet or igbt

Reply
SwagatamAdmin
December 28, 2013 • 13 years ago #18607

yes that could be tried….

Reply
edalcor zuproc
September 10, 2013 • 13 years ago #15078

ok thanks you for you reply.

Reply
Azam Ali
September 16, 2013 • 13 years ago #15353

In your case there are 3 solutions one described by Mohammad junaid.
2nd is to to 3 phase a.c. supply to d.c. supply then again converting it to single phase a.c. supply from d.c. but it is costly.
3rd on is by replaceing old 3phse alternor with new one single phase alternator.
may be 2nd solution is more costly by 1st or 3rd solution.
but before thinking about implemention on any suggesion i advise you to download and read information about preinstalled 3 phase alternator may by its output winding is
star ( Y ) conneted then there is a nutral or common terminal in its connection box.

Reply
Azam Ali
September 16, 2013 • 13 years ago #15352

Hi swatgatam Majumdar you are doing good job and i like your work it is very helpful for bigners or students

Reply
SwagatamAdmin
September 17, 2013 • 13 years ago #15369

Thank you Azam Ali.

Reply
Chivindwe
November 7, 2013 • 13 years ago #17055

Thank you very much sir,
Now just how do we connect these three outputs transistors (MOSFETs) and then to a transformer to realize a usable three phase 380V phase to phase that can be used to power motors?

Reply
SwagatamAdmin
November 8, 2013 • 13 years ago #17084

You will need the following circuits to implement it:

https://www.homemade-circuits.com/2013/10/three-phase-inverter-circuit.html

Reply
karuna
February 5, 2014 • 12 years ago #19639

sir i had one doubt hw did u say the value of R=10Kohms

Reply
SwagatamAdmin
February 7, 2014 • 12 years ago #19664

yes

Reply
harshal sharma
February 17, 2014 • 12 years ago #19895

sir i would like to ask you one question??
i have made a three phase detection circuit in which if the supply goes from RYB TO RBY the circuit detects and gives signal to the relay
but i have one doubt
how should i connect the three phase supply as an input to the circuit
i can not connect directly
i have to create a signal of it
so how will i make that signal which is beyond my knowledge
i can mail you my circuit through gmail
my id is harshal.sharma055@gmail.com
please help me

Reply
SwagatamAdmin
February 17, 2014 • 12 years ago #19907

Hi Harshal, it's a bit tricky, I do not know the correct way of doing it, if i figure it out I'll inform you regarding it.

Reply
harshal sharma
February 18, 2014 • 12 years ago #19934

u have added me in google + so i can mail u the circuit of three phase detection circuit u can then help me out will it work or not …

Reply
SwagatamAdmin
February 19, 2014 • 12 years ago #19957

yes, you can.

Reply
harshal sharma
February 26, 2014 • 12 years ago #20150

hey gud morning swagatam , i have made the three pulse generator , now its shown a single phase source as an input ,from where ill get this single phase source directly from the supply ??
if yes , i did that the the 1st resistor burn out
please help me

Reply
harshal sharma
February 26, 2014 • 12 years ago #20155

in the above circuit what will be the input source i mean what rating
i used it with the230V SINGLE PHASE SUPPLY
and the circuit burn out

Reply
SwagatamAdmin
February 26, 2014 • 12 years ago #20163

Hi Harshal, since the circuit is 12V operated, the input should also be stepped down to 12V AC signal. You can do it by connecting a 0.1uF/400V capacitor in series with the input 10k resistor.

THe outputs will then require half driver circuits to convert the relevant small signal phase shifts into 220V 3-phase AC.

Reply
harshal sharma
February 28, 2014 • 12 years ago #20201

hi swagatam , i m sharing a link from the google drive of the three phase detection circuit
related to that i need ur help
in tat circuit 3 phase input is needed
so i m making a three phase signal using a three phase generator
butwill it work>///?????
link is
https://drive.google.com/file/d/0B7f8SlTe2xORci1SbjMzcGN0LXM/edit?usp=sharing

Reply
SwagatamAdmin
March 1, 2014 • 12 years ago #20223

Hi Harshal,

Make the above circuit and confirm whether you are getting the 120 degrees phase shifts or not by applying a 12V sine AC at the input…..once it's confirmed you can use it with this circuit for the detection.

you will need an oscilloscope for confirming this.

Reply
harshal sharma
February 28, 2014 • 12 years ago #20202

i want to knoe more about this driver circuit is it an inverter circuit??

Reply
SwagatamAdmin
March 1, 2014 • 12 years ago #20224

please refer to the last diagram given in the following link:

https://www.homemade-circuits.com/2013/10/three-phase-inverter-circuit.html

Reply
Jagan S
February 28, 2014 • 12 years ago #20206

Sir,

How do we generate -12V to connect to pin # 11. And I suppose all the numbers indicated on A1–A4 is the pin numbers of the respective IC.

Reply
SwagatamAdmin
March 1, 2014 • 12 years ago #20226

Jagan, you will need a dual power supply for that, you can easily make a dual power supply by using a center tap transformer or by using a resistive network with a 24V single supply.

Yes those indicate the IC pin numbers.

Reply
harshal sharma
March 1, 2014 • 12 years ago #20239

Jagan ull need to make a dual supply using a centered tapped transformer of 220/15 -0-15 V AND USING 7912 IC u can get -12 volt supply

Reply
harshal sharma
March 1, 2014 • 12 years ago #20240

hi swagatam, i m really thankful to you coz of ur quick response to me
one last question i need to know the use of 0.1 microfarad 400v capacitor y to use it with the input?? is it necessary ??after using this capacitor should i hav to step down the voltage or i can directly connect the input to the supply

Reply
SwagatamAdmin
March 1, 2014 • 12 years ago #20248

Hi Harshal,
with a 0.1uF cap in series you can provide the supply from the mains directly, however it would be rather better to eliminate the capacitor and provide the input from a 0-12V transformer, this would kepp the circuit isolated and ensure safety from mains lethal voltages

Reply
Emeka Ukaegbu
March 1, 2014 • 12 years ago #20250

Hey swagatam. I want to use this circuit for ac induction motor, please tell me if this circuit is working well. Also I want to know if anyone has build this circuit, thanks and please reply sooners

Reply
SwagatamAdmin
March 2, 2014 • 12 years ago #20261

Emeka, you cannot use the above circuit directly with motor, you will have to employ a three phase driver circuit with it for operating the motor, please refer to the last circuit given in the following link:

https://www.homemade-circuits.com/2013/10/three-phase-inverter-circuit.html

Reply
harshal sharma
March 5, 2014 • 12 years ago #20308

hi swagatam, i made the above circuit, its not working
i m not getting a sinusoidal pulse as an output

Reply
harshal sharma
March 5, 2014 • 12 years ago #20315

also when i measure the voltage across capacitor with multimeter i m getting voltage of 12 v but its d.c. not a.c so now what to do??

Reply
SwagatamAdmin
March 5, 2014 • 12 years ago #20318

Hi harshal,

you will need an oscilloscope to confirm the outputs, there's no other method of confirming an AC sine output with 120 degree phase shifts.

Reply
harshal sharma
March 5, 2014 • 12 years ago #20319

i checked it swagat. but i m not getting a pure sine output also when i m measuring it with the multimeter the output i m getting voltages for both d.c .and a.c
i saw harmonics in the output so couldnt measure the phase sequence
please help me
also the resistance value decreased from 10 K to 8.5 K
so should i change the resistances???
n how to give ground to that single phase source ??

Reply
harshal sharma
March 5, 2014 • 12 years ago #20320

do u have whatsapp messenger so that i can directly be in your contact this will also ease my time as my project dead time is last of april month
???my mobile no. is +918460285967
harshal sharma

Reply
SwagatamAdmin
March 5, 2014 • 12 years ago #20326

In the meter it will only show RMS values, 12V in AC range and 6V in DC range.

Actually the above circuit is not my design and I have not tested it practically, so it will be difficult for me to troubleshoot the circuit correctly.

sorry I do not have a whatsapp account.

Reply
SwagatamAdmin
March 5, 2014 • 12 years ago #20329

what response did you get in the scope? Check the phase shift angle only, that's important…

Reply
harshal sharma
March 5, 2014 • 12 years ago #20321

also i have shared a link previous a circuit of 3 phase phase detection circuit
wich has 10v zener diode , so shold i change it to 5v zener diode???

Reply
SwagatamAdmin
March 5, 2014 • 12 years ago #20328

I haven't yet studied the circuit yet, if you can tell the role of the zener in the circuit then I can suggest whether it needs a change or not

Reply
harshal sharma
March 5, 2014 • 12 years ago #20322

i m trying to make a project which includes the controlling of elevator for 3 floor building, undervoltage and over voltage protection circuit and the three phase detection and protection circuit, well i hav made the controlling and o.v and u.v protection circuit but i am now stuck on this three phase detection and correction circuit??

Reply
SwagatamAdmin
March 5, 2014 • 12 years ago #20327

I'll try to find some other circuit which can create artificial 3-phase signals that you can use for confirming with your detector stage.

Reply
View Older Comments

Need Help? Please Leave a Comment! We value your input—Kindly keep it relevant to the above topic! Cancel reply

Your email address will not be published. Required fields are marked *

Primary Sidebar



Categories

  • Arduino Projects (95)
  • Audio and Amplifier Projects (134)
  • Automation Projects (18)
  • Automobile Electronics (103)
  • Battery Charger Circuits (88)
  • Datasheets and Components (109)
  • Electronics Theory (150)
  • Energy from Magnets and Earth (40)
  • Games and Sports Projects (11)
  • Grid and 3-Phase (20)
  • Health related Projects (27)
  • Home Electrical Circuits (13)
  • Indicator Circuits (16)
  • Inverter Circuits (100)
  • Lamps and Lights (163)
  • Meters and Testers (72)
  • Mini Projects (28)
  • Motor Controller (68)
  • Oscillator Circuits (28)
  • Pets and Pests (15)
  • Power Supply Circuits (91)
  • Remote Control Circuits (50)
  • Security and Alarm (65)
  • Sensors and Detectors (107)
  • SMPS and Converters (46)
  • Solar Controller Circuits (61)
  • Temperature Controllers (43)
  • Timer and Delay Relay (50)
  • Voltage Control and Protection (44)
  • Water Controller (37)
  • Wireless Circuits (31)



Circuit Simulator

circuit simulator image



Subscribe to get New Circuits in your Email



Other Links

  • Privacy Policy
  • Cookie Policy
  • Disclaimer
  • Copyright
  • Videos
  • Sitemap

People also Search

555 Circuits | 741 Circuits | LM324 Circuits | LM338 Circuits | 4017 Circuits | Ultrasonic Projects | SMPS Projects | Christmas Projects | MOSFETs | Radio Circuits | Laser Circuits | PIR Projects |



Recent Comments

  • Swagatam on PWM Inverter Using IC TL494 Circuit
  • Swagatam on Bicycle Generator Circuit
  • Swagatam on Digital Capacitance Meter Circuit Using Arduino
  • Swagatam on 7 Easy Voltage Doubler Circuits Discussed
  • wayne m on PWM Inverter Using IC TL494 Circuit

Social Profiles

  • Twitter
  • YouTube
  • Instagram
  • Pinterest
  • My Facebook-Page
  • Stack Exchange
  • Linkedin

© 2026 · Swagatam Innovations