• Skip to main content
  • Skip to primary sidebar

Homemade Circuit Projects

Need circuit help? Post them in the comments! I've answered over 50,000!

Blog | Categories | About | Contact | Calculators-online
You are here: Home / Lamps and Lights / 40 watt Electronic Ballast Circuit

DIY Circuits | Learn Basics | Arduino Coding




40 watt Electronic Ballast Circuit

Last Updated on January 2, 2024 by Swagatam 111 Comments

The proposed 40 watt electronic ballast is designed to illuminate any 40 watt fluorescent tube, with high efficiency, and optimal brightness.

The PCB layout of the proposed electronic fluorescent ballast is also provided along with the torroid and the buffer choke winding details.

Introduction

Even the promising and the most talked about LED technology is perhaps unable to produce lights equal to the modern electronic fluorescent ballasts lights.

The circuit of one such electronic tube light is discussed here, with efficiency better than LED lights.

Just a decade ago electronic ballasts were relatively new and due to frequent failures and high costs were not generally preferred by everyone.

But with passing time the device went through some serious improvements and the results were encouraging as they started becoming more reliable and long lasting.

The modern electronic ballasts are more efficient and fail proof.

Difference between Electrical Ballast and Electronic Ballast

So what’s the exact advantage of using electronic fluorescent ballast compared to the age old electrical ballast?

To understand the differences correctly it is important to know how ordinary electrical ballasts work.

Electrical ballast is nothing but a simple high current, mains voltage inductor made by winding number of turns of copper wire over laminated iron core.

Basically, as we all know a fluorescent tube requires a high initial current thrust to ignite and make the electrons flow connect in between its end filaments.

Once this conduction is connected the current consumption to sustain this conduction and the illumination becomes minimal.

Electrical ballasts are used just to “kick” this initial current and then control the supply of the current by offering increased impedance once the ignition is completed.

Use of a Starter in Electrical Ballasts

A starter makes it sure that the initial “kicks” are applied through intermittent contacts, during which the copper winding’s stored energy is used to produce the required high currents.

The starter stops functioning once the tube gets ignited and now since the ballast is routed via the tube, starts getting a continuous flow of AC through it and due to its natural attributes offers high impedance, controlling the current and helping sustain optimal glow.

However, due to variation in voltages and lack of an ideal calculation, electrical ballasts can become quite inefficient, dissipating and wasting a lot of energy through heat.

If you actually measure you will find that a 40 watt electrical choke fixture may consume as high as 70 watts of power, almost double the required amount. Also, the initial flickers involved cannot be appreciated.

Electronic Ballasts are More Efficient

Electronic ballasts on the other hand are just the opposite as far as efficiency is concerned. The one which I built consumed just 0.13 Amps of current @ 230volts and produced light intensity that looked much brighter than normal.

The have been using this circuit since last 3 years without no problems whatsoever (though I had to replace the tube once as it blackened at the ends and started producing lesser light.)

The current reading itself proves how efficient the circuit is, the power consumption being just around 30 watts and an output light equivalent to 50 watts.

How the Electronic Ballast Circuit Works

Its working principle of the proposed electronic flourescent ballast is rather straightforward. The AC signal is first rectified and filtered using a bridge/capacitor configuration.

The next comprises a simple two transistor cross-coupled oscillator stage. The rectified DC is applied to this stage which immediately starts oscillating at the required high frequency.

The oscillations are typically square wave which is appropriately buffered via an inductor before it is finally used to ignite and illuminate the connected tube.

The diagram shows a 110 V version which can be easily modified into 230 volt model through simple alterations.

The following illustrations clearly explains how to build a homemade electronic 40 watt electronic fluorescent ballast circuit at home using ordinary parts.

40 watt electronic ballast PCB layout component placement

PCB Component Layout

WARNING: PLEASE INCLUDE A MOV AND A THERMISTER AT THE SUPPLY INPUT, OTHERWISE THE CIRCUIT WILL BECOME UNPREDICTABLE AND MIGHT BLOW-OFF AT ANY MOMENT.

ALSO, MOUNT THE TRANSISTORS OVER SEPARATE, 4*1 INCH HEATSINKS, FOR BETTER EFFICIENCY AND LONGER LIFE.

40 watt electronic ballast PCB design with tracks

PCB Track Layout

Torroid Inductor

40 watt electronic ballast T13 torroid wiring details

Choke Inductor

40 watt electronic ballast choke

Parts List

  • R1,R2,R5 = 330K MFR 1%
  • R3,R4,R6,R7=47 Ohm, CFR 5%
  • R8=2.2 Ohms, 2watts
  • C1,C2=0.0047/400V PPC for 220V, 0.047uF/400V for 110V AC input
  • C3,C4=0.033/400V PPC
  • C5=4.7uF/400V Electrolytic
  • D1=Diac DB3
  • D2……D7=1N4007
  • D10,D13=B159
  • D8,D9,D11,D12=1N4148
  • T1,T2=13005 Motorola
  • Heatsink is required for T1 and T2.

Electronic Ballast Circuit for Twin 40 Watt Fluorescent Tubes

The next concept below explains how to build a simple yet extremely reliable electronic ballast circuit for driving or operating two 40 watt fluorescent tubes, with an active power correction.

Courtesy: https://www.irf.com/technical-info/appnotes/an-995a.pdf

Main Electrical Features of the IC

International Rectifier Control ICs are monolithic power integrated circuits suitable for operating low-side and high-side MOSFETs or lGBTs through logic level, referenced to ground input leads.

They feature balanced out voltage functionality as much as 600 VDC and, contrary to ordinary driver transformers, can bring super-clean wave-forms with virtually any duty-cycle from 0 to 99%.

The IR215X sequence is actually a recently available accessory to the Control IC family and, besides the previously mentioned characteristics, the product employ a top end comparable in performance to the LM 555 timer IC.

These types of driver chips give you the developer with self oscillatory or coordinated vacillation capabilities purely with the help of alternative RT and CT components See figure below

Electronic Ballast Circuit for Single 40 Watt Fluorescent Tubes

Parts List

  • Ct/Rt = same as given in the below given diagrams
  • lower diodes = BA159
  • Mosfets: as recommended in below diagrams
  • C1 = 1uF/400V PPC
  • C2 = 0.01uF/630V PPC
  • L1 = As recommended in below diagram, may need some experimentation

They likewise have in-built circuitry which offers a moderate 1.2 microsecond dead-time between outputs and switching high side and low side components for driving half-bridge power devices.

Calculating The Oscillator Frequency

Whenever included in the self oscillatory form the frequency of oscillation is calculated simply by:

f = 1/1.4 x (Rt + 75ohm) x Ct

The three accessible self-oscillating devices are IR2151, IR2152 and IR2155. IR2I55 seems to have more substantial output buffers that will turn a 1000 pF capacitive load with tr = 80 ns and tf = 40 ns.

It includes minuscule power start-up and 150 ohm RT supply. IR2151 possesses tr and tf of 100 ns and 50 ns and performs much like IR2l55.

IR2152 will be indistinguishable to IR2151 although with phase cambio from Rt to Lo. IR2l5l and 2152 include 75 ohm Rt source (Equation l.)

These types of ballast drivers usually are meant to be furnished with the rectified AC input voltage and consequently these are intended for minimal quiescent-current and still have a l5V in-built shunt regulator to ensure that just one limiting resistor works extremely well through the DC rectified bus voltage.

Configuring the Zero Crossing network

Looking yet again to Figure 2, be aware the synchronizing potential of the driver. Both back-to-back diodes in line together with the lamp circuit are efficiently configured as a zero crossing detector for the lamp current. Ahead of the lamp strike, the resonant circuit involves L, C1 and C2 all in a string.

C1 is a DC blocking capacitor having a low reactance, in order that the resonant circuit is successfully L and C2. The voltage around C2 is amplified by way of the Q factor of L and C2 at resonance and hits the lamp.

How the Resonant Frequency is Determined

As soon as the lamp strikes, C, is appropriately short circuited by the lamp potential drop, and the frequency of the resonant circuit at this point is determined by L and Cl.

This leads to a change to some lower resonant frequency in the course of standard operations, just as before coordinated through sensing the zero-crossing of the AC current and taking advantage of the resulting voltage to regulate the driver oscillator.

Along with the driver quiescent current, you will find a couple of additional elements on DC supply current which are a functionality of the very application circuit:

Evaluating Current and Charge Discharge Parameters

l) Current as a result of charging the input capacitance of the power FETs

2) current resulting from charging and discharging the junction isolation capacitance of the International Rectifier gate driver devices. Each components of current arc charge-relatcd and for that reason stick to the rules:

  • Q = CV

It could conveniently be observed, consequently, that to be able to charge and discharge the power device input capacitances, the expected charge can be a product of the gate drive voltage and the true input capacitances and also the input power recommended will be specifically proportionate to the product of charge and frequency and voltage squared:

  • Power = QV^2 x F / f

The above mentioned associations propose the below factors when making a real ballast circuit:

1) pick the smallest working frequency according to decreasing inductor dimension;

2) opt for the most compact die volume for the power devices dependable with reduced conduction deficits (that minimizes the charge specifications);

3) DC bus voltage is normally selected, however , if there exists a alternative, make use of the minimum voltage.

NOTE: Charge is simply not a functionality of switching rate. The charge transmitted is the very same with regard to I0 ns or 10 microsecond transition times.

We will at this point take into account a few useful ballast circuits which can be achievable using the self-oscillating drivers. Probably the most well-liked fluorescent light fixture may be the so called ‘Double 40’ type which often employs a couple of typical Tl2 or TS lamps within a common reflectante.

A pair of recommended ballast circuits are demonstrated in the following figures. The first is the minimal power factor circuit, along with the other works with a novel diode/capacitor settings to accomplish a power factor > 0.95. The lower power factor circuit proven in figure 3 welcomes 115 VAC or 230 VAC 50/60/400 Hz inputs to generate a moderate DC bus of 320 VDC.

Twin 40 Watt Ballast Circuit Diagram

Ballast Circuit for Double 40 Watt Fluorescent Tubes
twin 40 watt Electronic Ballast Circuit with PFC protection

Considering that the input rectifiers carry out just close to the peaks of the AC input voltage, the input power factor is around 0.6 lagging with a non-sinusoidal current wave-form.

Such type of rectifier is simply not advised for anything at all apart from an assessment circuit or reduced power compact fluorescent and without a doubt could become unwanted as harmonic currents in power supply devices are additionally lessened by power quality restrictions.

The IC uses a Limiting Resistor only to Operate

Observe that the International Rectifier IR2151 Control IC performs directly off thc DC bus by way of a limiting resistor and pivots at close to 45 kHz in conformity with the given relationship:

  • f = 1/1.4 x (Rt + 75ohm) x Ct

Power for the high side switch gate drive arises from a bootstrap capacitor of 0.1 pF and that is charged to roughly 14V anytime V5 (lead 6) is dragged low within the low side power switch conduction.

The bootstrap diode l IDF4 prevents the DC bus voltage as soon as the high side change conducts.

A fast recovery diode ( <100 ns) is necessary to be certain that the bootstrap capacitor will not be moderately discharged since the diode comes back and obstructs the high voltage bus.

The high frequency output in the half-bridge is actually a square wave with extremely fast changeover periods (around 50 ns).

To avoid abnormal extended noises through the fast wave fronts, a 0.5W snubber of 10 ohm and 0.001 pF is employed to minimize the switch periods to just about 0.5 ps.

Featuring a Built-in Dead Time Facility

Observe that we have a built-in dead time of 1.2 ps in the IR2151 driver to stop shoot-through currents in the half-bridge.

The 40 watt fluorescent lamps are controlled in parallel, each using its own L-C resonant circuit.

Approximately four tube circuits could be operated from a single set of two MOSFETs measured to match the power level.

The reactance valuations for the lamp circuit are picked from L-C reactance tables or through the formula for series resonance:

  • f = 1/2pi x square-root of LC

The Q of the lamp circuits is pretty small simply because of the advantages of functioning from a fixed rate of recurrence which usually, obviously, may differ due to RT and CT tolerances.

Fluorescent lights tend not to generally need extremely high striking voltages therefore a Q of 2 or 3 is enough. ‘Flat Q` curves often originate from bigger inductors and small capacitor ratios in which:

Q = 2pi x fL / R, wherein R is often greater because a lot more turns are employed.

Soft-starting during tube filament pre-heating may be inexpensively contained by utilizing PTC. thermistors around each lamp.

In this manner, the voltage along the lamp steadily boosts as the RTC. self-heats right up until eventually the striking voltage together with hot filaments is achieved and the lamp illuminates.

You'll also like:

  • automaticdoorlampcircuitAutomatic Door Lamp Timer Circuit
  • Greatest Myths about LED Lighting
  • a 2Blinking an LED with Arduino – Complete Tutorial
  • High quality 3 watt rgb led withSimple Scrolling RGB LED Circuit

Filed Under: Lamps and Lights Tagged With: Ballast, Electronic, Watt

About Swagatam

I am an electronics engineer and doing practical hands-on work from more than 15 years now. Building real circuits, testing them and also making PCB layouts by myself. I really love doing all these things like inventing something new, designing electronics and also helping other people like hobby guys who want to make their own cool circuits at home.

And that is the main reason why I started this website homemade-circuits.com, to share different types of circuit ideas..

If you are having any kind of doubt or question related to circuits then just write down your question in the comment box below, I am like always checking, so I guarantee I will reply you for sure!

Previous Post: « 2 Simple Earth Leakage Circuit Breaker (ELCB) Explained
Next Post: 3 Accurate Refrigerator Thermostat Circuits – Electronic Solid-State »

Reader Interactions

Comments

Gilberto Diaz-Castro says:
November 15, 2023 at 9:49 pm

Hello Mr. Swagatam

1. Do you sell the circuit board for this project?

2. How do I go about updating a 4-tube light fixture with 120VAC input power?

Thanks.

Reply
Swagatam says:
November 16, 2023 at 9:00 am

Hi Gilberto,
Sorry, I do not have ready PCBs for this project.
I think you can easily procure these tube lights from amazon and get it installed by any local electrician.

Reply
Amit Khobragade says:
December 3, 2021 at 1:24 pm

Hello,
Any Ideas for T5 8W Florescent tubes.?
Thanks.

Reply
Swagatam says:
December 3, 2021 at 4:18 pm

Hi, sorry, presently I do not have this circuit with me….

Reply
kayvan ahmadi says:
September 28, 2020 at 8:52 pm

hi dear Swagatam
i made the ballast without any ic and drive 2 lamps using the scheme expressed in the document :
https://www.homemade-circuits.com/wp-content/uploads/2020/09/ballast.pdf
its good for drive 1 lamp, but at the 2 lamps, if i remove the connection of one lamps, the ballast will explode …. and burned …..

how can i prevent this?

thanks for your answer

Reply
Swagatam says:
September 29, 2020 at 10:39 am

Hi kayvan,

you can try adding a current control feature in the design as shown below:

ballast current control

Make sure to calculate the Rx value correctly for proper cut off during an over current

Reply
sedigh hosein says:
September 6, 2019 at 6:23 am

hi dear sir let’s me ask a question from you
whether it is possible for using ir2151 chip as an driver smps power supply whether exsiting a pin on ir2151 chip to control optocopler to cut off fluctaunce on chip i bought five tny 268 with 25 w power but all those get blowing meaning although be exsiting 100 w sereis lamp but since last a few time lamp light brighting and inside chip mosfet as get short circuit

Reply
Swagatam says:
September 6, 2019 at 12:41 pm

Hi Sedign, yes that’s possible, the Ct can be used as the control pin. Grounding this will shut down the circuit

Reply
Umapathi says:
November 9, 2017 at 10:19 pm

Hi sir .I have one doubt .36 watts tube light ballast use for 2* 14 watts 2 feet lamb (T5 essential lamb) . Its connected to parallel.if it is possible .it will work.

Reply
Ananth says:
July 5, 2018 at 2:03 pm

Hot to calculate the choke coil inductor number of turns guage and diameter for different watt.
26 w, 36 w, & 40 watt.

Reply
Swagatam says:
July 5, 2018 at 3:20 pm

I did not calculate I just used maximum number of turn that could fit inside the bobbin

Reply
Ananth says:
July 5, 2018 at 4:09 pm

Okay, I tried with different windings and air gaps, according bright ness also was changing. But still I need to see the exact windings, gaps for max efficiency

Reply
Swagatam says:
July 5, 2018 at 4:50 pm

yes the choke acts like a current limiter and could affect the brightness if not optimized correctly.
Please remember I had used a 100 watt bulb in series while using it in my home with 220V AC, for 3 long years. The bulb safeguarded the ballast from sudden current and voltage surges and allowed it to work flawlessly with awesome brightness. The bulb filament hardly showed any glow in it

the above method looks very crude so you may think of adding something more advanced such as adding an MOV, NTC or a feedback shut-down loop.
However for 110V AC no current limiter becomes necessary

Reply
Ananth says:
July 5, 2018 at 8:22 pm

I have added 4.7 5 w resistor instead of bulb. For me 5 years tube and choke was v good. After 5 years only I need to change one filter capacitor. Due to heat its electrolyte dried up.
Hence calculation of turns is the major work.
LED also lasts only for say 2 years. After that its PCB will give problem.
Hence ordinary tube with electronic blast is good. At least we can change some component.

Reply
Swagatam says:
July 6, 2018 at 10:44 am

thanks for sharing your views, I think 5 years is quite a long period of time.
I wish I could tell you regarding the choke winding calculation, however presently I do not have it therefore cannot help you with it.

Reply
Swagatam says:
November 10, 2017 at 8:10 am

Hi Umapathi, sorry, that won’t work.

Reply
Anup says:
December 30, 2020 at 10:31 am

Hi,
was your reply on use of 2ft tubes connected parallel for electronic ballasts use?

Reply
Swagatam says:
December 30, 2020 at 11:24 am

yes, two tubes connected in parallel can have problems due to their slight different firing specs.

Reply
Yash Mahajan says:
May 4, 2017 at 7:48 am

Hi!! I didn't get where the cathode of diode D2 is connected.. Please help..

Reply
Swagatam says:
May 5, 2017 at 3:37 am

Hi, please click on the on the diagram under the PCB Component Layout, you will be able to see the enlarged view of it…D2 could be clearly seen with its cathode downwards.

Reply
bissonath says:
September 3, 2017 at 5:24 pm

can u also please make the diagram sir.

Reply
bissonath says:
September 3, 2017 at 4:12 pm

how the output can be reduced to 33 watts sir?

Reply
Swagatam says:
September 4, 2017 at 2:55 am

by reducing C3/C4 to some lower value

Reply
Swagatam says:
January 8, 2017 at 3:01 pm

Jayanta, you can try an MOV having 300V as its clamping voltage….

you can read the following article for more info

https://www.homemade-circuits.com/2016/05/how-to-select-mov.html

Reply
Jayanta Nath says:
January 7, 2017 at 6:04 pm

Thanks brother for your reply is there any specific code value for mov if so kindly providemail me the number code for mov.

Reply
Swagatam says:
January 7, 2017 at 5:21 am

Jayanta, the phase neutral connections are not critical for any AC device….you can freely connect the phase/neutral anyway you like across the ballast it won't harm anything in the circuit.

Your ballast burned because of voltage fluctuations….you could try employing an NTC at the input along with an MOV for preventing such mishaps.

Reply
Jayanta Nath says:
January 6, 2017 at 5:43 pm

Dear brother I have connected an electronic choke with ac like this way as it phase is connected directly to the input supply and it's neutral is connected via switch. But after some days of its working it choke blown away. My question is that is this due to the wrong input connection of ac supply to the choke. Please reply and thanks in advance jayanta

Reply
Jayanta Nath says:
January 4, 2017 at 5:18 pm

Dear broth what will happen if I put 22 mf 400 volt as c capacitor. In 40 watt electron ic blast. And if I use 13003 mje transistors

Reply
Swagatam says:
December 27, 2016 at 11:14 am

sorry jayanth, it would be impossible for me to judge the issue without practically investigating your circuit…

Reply
Rajkumar v says:
July 20, 2016 at 6:16 am

Dear sir, Please help me .In my home 2 tube light Electronic choke had burned after I have checked it i realized transister 13005ED and Cap 682J was burned but it is very rare to find kindly provide equivalent TRANSISTOR and cap

Thanks

Reply
Swagatam says:
July 20, 2016 at 11:09 am

Dear Raj, the transistor MJE13005 is very popular and should be available in almost parts of the world…moreover there's no easier alternative to this part.

the cap 682J can e replaced with 0.0068uF/250V

Reply
Nelio Abreu says:
April 29, 2016 at 6:44 pm

Thank you Swagatam.
Best Regards.
N.A.

Reply
Swagatam says:
April 30, 2016 at 2:01 am

You are welcome Nelio

Reply
Nelio Abreu says:
April 27, 2016 at 11:49 am

Hi Swagatam,
I'm looking for a 12V inverter circuit to power 2 T8 fluorescent lamps of 36W each. The circuit mas include a battery charger to work with a 12V SLA battery. Do you have anything like this?

Thanks.
Best Regards.
Nélio

Reply
Swagatam says:
April 27, 2016 at 1:49 pm

Hi Nelio,

for the inverter you can try the following circuit:

https://www.homemade-circuits.com/2012/07/simplest-and-best-100-watt-inverter.html

and for the charger the following design can be used:

https://www.homemade-circuits.com/2012/02/how-to-build-automatic-6-volt-12-volt.html

Reply
HARSHUL CHUDASAMA says:
March 31, 2016 at 2:51 pm

HOW CAN I CHECK MY CHILD IS ON?

Reply
Consumer Watchdog says:
February 16, 2016 at 6:44 am

Thank you for your fast and helpful replies.
Best regards.

Reply
Consumer Watchdog says:
February 14, 2016 at 3:55 am

Hello Mr. Swagatam Majumdar,
Thank you very much for all the information you posted on your website. It's very interesting and informative.
I am sorry if this question is sort of off topic but you know alot about electronics and I can't seem to find the answer.
I have been making portable insect traps that I use with a 12 volt Gel cell battery and a 40 watt fluorescent UV light bulb (u shaped type bulb).
I have been buying simple DC ballasts from China that are rated to be used for fluorescent bulbs that are 10-40 watts. The ballasts work, however, they don't seem to reach their full brightness. When I measure the current, it only measure 1.2 amps with a 40 watt bulb. This seems much too low and I assume it should be 3.3 amps. So I'm assuming that this ballast is really only a 20 watt DC ballast and I am using the wrong ballast.
I have ordered some other 40 watt DC ballasts to test them.
My question is:
1. If a DC ballast is rated at 40 watts and you use a 40 watt lamp, should the current be 3.3 amps? If it is lower, does that mean you are not getting the full wattage of the lamp?
2. I have read that it's ok to use a 20 watt bulb on a 40 watt ballast. It may shorten the life of the bulb somewhat but it will run ok. If you use a 20 watt bulb on a 40 watt ballast, will the current drop to 1.7 amps or will it remain at 3.3 amps because the ballast is 40 watts?
I am sorry if these questions or off topic. Unfortunately, i do not have the skills to build my own ballast and must purchase them but it is often difficult to find quality DC ballasts.
Thank you

Reply
aris says:
October 6, 2020 at 1:19 pm

i dont know how to construct the ballast winding of 12volts dc supply and 20 watts output for flourescent .please tell me its core size(E I core),size in awg of magnetic wires and its number of turn

Reply
Swagatam says:
February 14, 2016 at 12:17 pm

Thank you Consumer Watchdog,

if the operating voltage is 12V then yes it should 40/12 = 3.33 amps
if it's lower then simply multiply it with 12 to get the effective wattage output from the ballast.
technically a 20 watt load can be operated with a 40 watt source if the voltage is compatible with the load, because if the voltage is as per the load spec then current will not matter or affect the load in any manner.
the current consumed by the 20 watt load will be 1.7amp

Reply
Consumer Watchdog says:
February 14, 2016 at 11:13 pm

Thank you so much for your helpful response. I'm sorry but I have one other question regarding the 20 watt lamp with the 40 watt ballast.
If I connect the 20 watt bulb to the 40 watt ballast and the current measured is high, say for example 2.5 amps, does that mean the bulb is being overdriven? i talked to a company that sells dc ballasts and he told me that there cheaper dc ballasts will over drive the 20 watt bulb connected to a 40 watt ballast and it will shorten the life of the lamp. However, they have more expensive dc ballasts that will adjust the current to match the bulb and they will not overdrive the 20 watt bulb and it will instead be only 1.7 amps as it should be.
Does this sound correct to you?
Thank you again.

Reply
Swagatam says:
February 15, 2016 at 4:40 am

Technically the current cannot become high, however since we are dealing with high frequency circuits, compatibility could be a critical factor and things could get unpredictable so if you see more current being consumed than the specified range then definitely the load is being overdriven and could get adversely affected in the long run.

Reply
Consumer Watchdog says:
February 14, 2016 at 11:05 pm

Thank you so much for your fast reply and informative answer. It is very much appreciated.
best regards,

Reply
shubhro shankar Ghatak says:
February 13, 2016 at 5:55 am

How can I get the ready made PCB card & spares part, kindly provide the link or address.
Also, Can you please provide a schematic diagram?

Reply
Swagatam says:
February 13, 2016 at 4:07 pm

I am sorry, PCB is not available ready made for this project

Reply
Ritish Kumar says:
December 3, 2015 at 7:18 am

no sir it should take turn after certain time interval

Reply
Swagatam says:
December 4, 2015 at 11:26 am

you will need a relay timer circuit for that but adjusting the turning angle will be complicated…or you can make it through a remote control design that will be more sensible and manageable

Reply
Chuawh says:
May 5, 2019 at 8:05 pm

Good Day Swagatam, regarding the 40w electronics ballast posted 2 month ago, where can I see the schematic diagram. Thank you.

Reply
Swagatam says:
December 2, 2015 at 11:46 am

how will it know the obstacles and the turns of the road??

Reply
Ritish Kumar says:
December 2, 2015 at 11:31 am

it should take turn after certain time intervals

Reply
View Older Comments

Need Help? Please Leave a Comment! We value your input—Kindly keep it relevant to the above topic! Cancel reply

Your email address will not be published. Required fields are marked *

Primary Sidebar

circuit simulator image



Subscribe to get New Circuits in your Email



Categories

  • Arduino Projects (93)
  • Audio and Amplifier Projects (133)
  • Automation Projects (17)
  • Automobile Electronics (101)
  • Battery Charger Circuits (85)
  • Datasheets and Components (109)
  • Electronics Theory (149)
  • Energy from Magnets (27)
  • Games and Sports Projects (11)
  • Grid and 3-Phase (20)
  • Health related Projects (27)
  • Home Electrical Circuits (13)
  • Indicator Circuits (16)
  • Inverter Circuits (95)
  • Lamps and Lights (159)
  • Meters and Testers (71)
  • Mini Projects (28)
  • Motor Controller (68)
  • Oscillator Circuits (28)
  • Pets and Pests (15)
  • Power Supply Circuits (91)
  • Remote Control Circuits (50)
  • Renewable Energy (12)
  • Security and Alarm (64)
  • Sensors and Detectors (106)
  • SMPS and Converters (34)
  • Solar Controller Circuits (60)
  • Temperature Controllers (43)
  • Timer and Delay Relay (49)
  • Voltage Control and Protection (42)
  • Water Controller (36)
  • Wireless Circuits (30)





Other Links

  • Privacy Policy
  • Cookie Policy
  • Disclaimer
  • Copyright
  • Videos
  • Sitemap



People also Search

555 Circuits | 741 Circuits | LM324 Circuits | LM338 Circuits | 4017 Circuits | Ultrasonic Projects | SMPS Projects | Christmas Projects | MOSFETs | Radio Circuits | Laser Circuits | PIR Projects |

Social Profiles

  • Twitter
  • YouTube
  • Instagram
  • Pinterest
  • My Facebook-Page
  • Stack Exchange
  • Linkedin



Recent Comments

  • Swagatam on 9 Simple Solar Battery Charger Circuits
  • Gagana on 9 Simple Solar Battery Charger Circuits
  • Swagatam on Arduino 2-Step Programmable Timer Circuit
  • Swagatam on Simple Buck-Boost Converter Circuits Explained
  • Swagatam on IC IR2111 H-Bridge MOSFET, IGBT Driver IC: Full Datasheet, Circuit Diagram

© 2026 · Swagatam Innovations