• Skip to main content
  • Skip to primary sidebar

Homemade Circuit Projects

Need circuit help? Post them in the comments! I've answered over 50,000!

Blog | Categories | About | Contact | Calculators-online
You are here: Home / Electronics Theory / How to Select MOV – Explained with a Practical Design

DIY Circuits | Learn Basics | Arduino Coding




How to Select MOV – Explained with a Practical Design

Last Updated on March 11, 2024 by Swagatam 110 Comments

MOVs or metal oxide varistors are devices designed for controlling mains switch ON surges in electrical and electronic circuits. Selecting an MOV for a particular electronic circuit might require some consideration and calculation, I have explained the procedures here.

What are MOVs

Metal oxide varistors or simply varistors are non-linear surge suppressor devices which are used for suppressing sudden, high abnormal voltage transients or surges, especially during power switch ON or thunder lightening situations.

These are mostly used in sensitive electronic circuits for safeguarding against such catastrophic occurrences.

Metal Oxide Varister

MOVs are basically non-polar, voltage dependent devices, meaning these devices will react to changes in voltage conditions.

Therefore MOVs are specified to trigger ON whenever the rated magnitude of voltage across their connections is exceeded.

This voltage rating at which an MOV may be rated to fire and short the transient to ground is called its clamping voltage specification.

For example, if suppose the clamping voltage rating of an MOV is 350V then it will switch ON whenever the voltage across it surpasses this limit.

When an MOV switches ON or is triggered by a high voltage surge it shorts the voltage spike across its terminals, preventing it from entering the vulnerable electronic device attached on the other side.

This action protects the electronic circuit from such accidental voltage surges and transient spikes.

And since the above reaction is sudden, MOVs are characterized as non-linear devices, which implies that these will not vary their characteristics gradually but suddenly when the specified parameters is exceeded.

The best characteristic of an MOV is its ability to absorb high current content accompanied with the voltage surge . Depending on the MOV specification the current absorbing capacity of an MOV could be anywhere between 1 amp to a massive 2500 amps

Current-voltage characteristic waveform of a typical zinc oxide MOV

Current-voltage characteristic waveform of a typical zinc oxide MOV

However the duration of the current handling feature of an MOV may be limited to a few microseconds only, which means the activation of an MOV under such sever situations can not be more than a few microseconds, otherwise it could burn the device and damage it permanently.

Therefore it is advised to use a fuse in series with the mains line in conjunction with the attached MOV for ensuring safety to both the electronic circuit and also to the MOV under a possible extreme catastrophic conditions.

ELECTRICAL CHARACTERISTICS

Typically the V/I characteristic of a ZnO varistor (MOV) can be understood with the following explanation:

The relationship between voltage and current of a varistor can be roughly estimated with the following formula

V = C x Iβ
where:
V = Voltage
C = Varistor voltage at 1 A
I = Actual working current
β = Tangent of angle curve deviating from the horizontal

Practical Example

When:
C = 230 V at 1 A
β = 0.035 (ZnO)
I = 10-3 A or 102 A
V = C x Iβ
so that for current of 10-3 A: V = 230 x (10-3)0.035 = 180 V and
for a current of 102 A: V = 230 x (102)0.035 = 270 V

Source: https://www.vishay.com/docs/29079/varintro.pdf

how to connect an MOV with mains AC input

 

How to Select an MOV

Selecting an MOV for a desired application is actually easy.

First determine the maximum peak safe operating voltage of the electronic circuit which needs the protection and then apply an MOV specified to conduct near about this voltage limit.

For example, suppose it's an SMPS device with a max capability of 285V RMS from the mains input, implies that the unit would be able to handle a peak mains surge of not more than 285/0.707 = 403V

The 403V figure provides us the max peak mains handling capacity of the SMPS circuit which must be avoided under any circumstances and therefore an MOV rated with a clamping voltage of around 400V could be applied to this SMPS safely.

The current rating of the MOV could be twice that of the SMPS rating, meaning if the SMPS wattage is rated at 24 watts at the secondary, then the primary could be calculated as 24/285 = 0.084 amps, therefore the MOV current could be anywhere above 0.084 x 2 = 0.168 amps or 200mA.

However a 200mA MOV could be difficult to obtain therefore a standard 1 amp device could be used for serving the purpose with utmost efficiency.

Note: Many countries have adopted a harmonized standard for AC power grid voltage typically around 230V with a tolerance of +10% and -6%. This means, the acceptable voltage range can fluctuate between 207V and 253V. Previously, some regions might have had a nominal voltage of 240V with an upper limit of 264V. However, under the new standard, the upper limit would be 253V. Therefore varistors rated for 270V or 275V could be suitable for protecting against voltage spikes in these regions.

You'll also like:

  • How to Compare IGBTs with MOSFETs
  • Calculating Filter Capacitor for Smoothing Ripple
  • BJT PNP NPN pinoutsHow to Connect Transistors (BJT) and MOSFET with Arduino
  • etching strategiesHow to Make PCB at Home (Easiest Method)

Filed Under: Electronics Theory Tagged With: Design, Explained, MOV, Practical, Select

About Swagatam

I am an electronics engineer and doing practical hands-on work from more than 15 years now. Building real circuits, testing them and also making PCB layouts by myself. I really love doing all these things like inventing something new, designing electronics and also helping other people like hobby guys who want to make their own cool circuits at home.

And that is the main reason why I started this website homemade-circuits.com, to share different types of circuit ideas..

If you are having any kind of doubt or question related to circuits then just write down your question in the comment box below, I am like always checking, so I guarantee I will reply you for sure!

Previous Post: « Camper, Motorhome Battery Charger Circuit
Next Post: Battery Bank Charger Circuit »

Reader Interactions

Comments

Bill Balogh says:
June 23, 2025 at 7:40 pm

I have a VTS Diode that burned up and I am uncertian how to select a new one. It is a 120vac control panel with a on off switch that turna on a solenoid and a old maginetic size 3 starter from the late 60’s.

I think I need 120V clamp,bidirectional, minimum of 188 reverse. but not 100% sure.

Reply
Swagatam says:
June 24, 2025 at 9:10 am

In that case please do not use a TVS diode, use an MOV with a clamping voltage of 150V peak.

Reply
Paul Turner says:
April 21, 2025 at 10:43 pm

Hi – I need an MOV to repair a bass guitar amplifier: TC Electronics RH750 model.
The MOV has become partly blackened which makes reading the value difficult but it’s in-circuit with 3 X 220R resistors in parallel which monitor the high dc voltage.
Would you happen to have any information on this amp please..?
Thanks, Paul

Reply
Swagatam says:
April 22, 2025 at 8:52 am

Hi, can you please tell, where was this MOV connected in your amplifier unit? I will try to figure it out…

Reply
Luke Anthony Moreno says:
February 3, 2025 at 12:38 pm

The 5vdc is an output from a PLC that goes to a normally open limit switch and when closed returns to the PLC . The 24vdc is just a start signal to energize a relay. I want to protect the PLC from any induced or stray voltage coming back on these paths.

Reply
Swagatam says:
February 3, 2025 at 5:09 pm

In DC circuits, reverse voltage can be blocked or bypassed using diodes. If you are concerned about high frequency noise then that can be eliminated by connecting capacitors across the supply line. I don’t think an MOV would be required in your case.

Reply
Luke Anthony Moreno says:
February 3, 2025 at 10:20 am

I have a 5vdc device and a 24vdc device to protect. What size MOV would I need? Thank you for taking my question.

Reply
Peter liewkongyow says:
September 26, 2025 at 10:35 am

most mov not had that’s lowered voltage tester ?

Reply
Swagatam says:
February 3, 2025 at 12:13 pm

Please provide more details regarding those devices, so that I can understand where the MOV needs to be installed?

Reply
Sandis says:
August 1, 2024 at 12:10 am

Hello! Can I use a tester to check the MOV VDR surge protectors or does the signal go through? I tried, but no signal goes through.

Reply
Swagatam says:
August 1, 2024 at 9:00 am

Hi, if you want to test an MOV, you can try the LAST circuit design explained in the following article:
https://www.homemade-circuits.com/testing-mov-metal-oxide-varistor-surge/

Reply
Prabhakar Pathy says:
June 16, 2024 at 5:33 pm

Which value mov can use for 230v RMS incoming Of full load current 6 Amp.

Reply
Swagatam says:
June 16, 2024 at 5:48 pm

for 230V the MOV rating can be 310V….current has nothing to do with MOV.

Reply
Peter says:
April 5, 2024 at 10:28 am

Does mov works best in DC voltage system ?

Reply
Swagatam says:
April 5, 2024 at 10:53 am

Yes, it will work with DC circuits also…

Reply
Randall Wilson says:
January 30, 2024 at 3:28 am

electric door strike call for MOV but not sized Need Help The strike is set up as 12-24 vac intermittent .280 – .565 A 37 0hm

Reply
Swagatam says:
January 30, 2024 at 8:42 am

You can use a 14V MOV for the 12V system and a 28 V MOV for the 24V system.

Reply
Ian says:
July 29, 2024 at 11:10 pm

This is also my question, as I install electric strike and maglocks. Can I jump on the back of this question and ask if when you say use a 14v and a 28v MOV is that referring to the clamp voltage? I have been looking on the RS and farnell website but cannot find them. Would you have a part number?

Reply
Swagatam says:
July 30, 2024 at 8:20 am

Yes, I am referring to the clamping voltage, you can find part number in these datasheet:

https://4donline.ihs.com/images/VipMasterIC/IC/LFSI/LFSI-S-A0007103731/LFSI-S-A0007103731-1.pdf?hkey=6D3A4C79FDBF58556ACFDE234799DDF0
https://in.element14.com/c/circuit-protection/tvs-transient-voltage-suppressors/tvs-varistors?voltage-rating-vdc=28v

Reply
Ian says:
August 2, 2024 at 12:14 am

Thanks for the reply but I am obviously missing something. Looking at the link you sent for the 28v MOV in the description it says the clamping voltage is 77v and not 28
https://in.element14.com/c/circuit-protection/tvs-transient-voltage-suppressors/tvs-varistors?voltage-rating-vdc=28v

And the littlefuse datasheet I can’t see one that will be correct for a 12dc lock. I have tried to read up on this and asked lots of questions but never really got a definite answer 🙂

Reply
Swagatam says:
August 2, 2024 at 8:27 am

Yes, the problem is that the MOV Clamping voltages are tied with their fixed Continuous voltage specifications, so even if we get the desired clamping voltage rating if it doesn’t match the continuous voltage rating, then it won’t be applicable.
I think instead of an MOV it is better to have a BJT voltage regulator, which can be customized as required.

Reply
laupin villemus bernard says:
January 8, 2024 at 2:37 pm

merci pour toutes ces infos , moi je met GMOV juste derrière le disjoncteur , et ça fonctionne !!!!

Reply
Swagatam says:
January 8, 2024 at 2:44 pm

Thank you Laupin, Glad it worked!

Reply
Josh Waldner says:
December 2, 2023 at 11:36 pm

Hi I have a control panel with 24 vdc relays inside that turn on and off what MOV do i need to protect from on/off surges. Thanks

Reply
Swagatam says:
December 3, 2023 at 6:21 am

Hi, what exactly do you want to protect, is it the relay or the load connected with the relay contacts? And what voltage is used with the load and the relay contacts?

Reply
Stryped says:
October 3, 2023 at 12:08 am

Ho can I protect with an mov a fridge compressor with 15 LRA and 1/3 hp? Standard 120v house currently?

Reply
Jim Garrioch says:
November 29, 2023 at 3:49 pm

The circuit in your diagram is dangerous.
The switch AND fuse should be in the live side. Assuming switch is in Live side, a blown fuse would leave the circuit at mains voltage.

Reply
Swagatam says:
November 29, 2023 at 5:40 pm

Thank you for notifying the issue, I have corrected the diagram accordingly.

Reply
Swagatam says:
October 3, 2023 at 9:15 am

Yes, to some extent, against extremely short voltage spikes.

Reply
Bahadır says:
August 17, 2023 at 4:16 pm

Hi sir, I’m curious about purchasing. When I am trying to buy mov there is too many different Voltage filters which I am drowning among them. For example in your example we found we need the MOV’s AC and DC voltage values. But there is Varistor Voltage, Clamping Voltage. I these values need to close to operating voltage. For example I found Mauser 331KM(E,N)20 for your circuit. It’s Vac 210v Vdc 330v. But It’s Varistor Voltage is 330V Clamping voltage is 550V. So is this Clamping Voltage is the maximum voltage it can handle or the value which lowered to after peak. Also in max continuous oe allowable voltage is lower than nominal voltage so I am really confused. Isn’t the nominal or rated voltage equal to systems operating voltage? I hope I have made myself clear and understandable. Love this site and your great work btw.
Sincerely

Reply
Swagatam says:
August 17, 2023 at 6:10 pm

Hi Bahadir,
The crucial aspect while selecting an MOV is its clamping voltage which must be slightly higher than the peak input voltage of the application. For example, the 220V AC is the RMS voltage and its peak voltage will be around 310V, so the MOV clamping voltage could be around 330V.

Reply
Farrukh says:
June 26, 2023 at 3:51 pm

can MOV be placed in power extension board to save Airconditioner by voltage higher than 260 V ac

Reply
Swagatam says:
June 26, 2023 at 5:37 pm

MOVs can stop high voltages which occur only for milliseconds, anything higher than that can burn the MOV itself.

Reply
Andreas says:
August 25, 2022 at 3:21 pm

I built a power strip/extension for my hifi/pc systems and I want to add a MOV in each power socket. There are 4 of them in a star configuration.
The voltage is 220v where I live and the the current reaching the power strip is 16A.

What varistor should i use for this application? voltage, amperes and diameter.

Reply
Swagatam says:
August 25, 2022 at 7:06 pm

You can use standard MOVs having a clamping voltage rating of 350V

Reply
Kishor Shamrao Lokhande says:
August 12, 2022 at 1:37 pm

I have luminous shakti charge 1450 inverter
Please tell me which MOV to be used in input line or ele.supply line.

Reply
Swagatam says:
August 12, 2022 at 6:08 pm

If your inverter output voltage is 220V, you can use a 350V MOV.

Reply
Micah Olali says:
August 6, 2022 at 8:25 pm

How can I build a DC battery charger from AC source without using transformer

Reply
Swagatam says:
August 6, 2022 at 8:36 pm

You can use an SMPS power supply.

Reply
Souvik Ghosh says:
June 24, 2022 at 11:22 pm

Can you please tell me which MOV is suitable for G3MC202-PL SSR??

Reply
Swagatam says:
June 25, 2022 at 9:02 am

Where do you want to place this MOV?

Reply
Swagatam says:
March 11, 2024 at 12:44 pm

Thank you so much Aries1470, for the valuable information,
I have added it at the end of the above post.
All the best to you.

Reply
Aries1470 says:
March 11, 2024 at 11:52 am

Hello Swagatam,
I would like to bring to your attention another option for calculating R.M.S. ? in the following paragraph:
“For example, suppose it’s an SMPS device with a max capability of 285V RMS from the mains input, implies that the unit would be able to handle a peak mains surge of not more than 285/0.707 = 403V”
It can also be done by 285V * 1.414. = 403.
In most countries, the harmonized standard is now 230V +10% -6%, although the transfer period varies. So, while previously for the 240V it was accepted to reach 264V it is now 253V. So 270V / 275V varistors can be used. You might want to add it in to your article. I am aware that Australia is transitioning to the European standard, but i have not search about it for the U.K., India & New Zealand, while the Philippines uses 230V, some old buildings / locations might still have 115V, but the whole country runs on 60Hz.
Most now go by the power grid instead of the appliance itself, as there might be other items attached, unless it is application specific.

Take care.

Reply
Swagatam says:
February 28, 2024 at 7:46 am

Thank you Aries1470,
The information you have added are really useful, I hope the readers will find them helpful.

Reply
aries1470 says:
February 28, 2024 at 5:45 am

I would like to add, that if you have ANY other loads, like washing machines, refrigerators etc, they will be chipping away at your MOV slowly until it fails without EVER having to have dealt with a lightning strike. For example, if you are in a 240V country, and you use a 10mm disc type MOV, and you have it as a surge protector, you need to remember, that BESIDES, the power outlet that you have it hooked up to, it also protects up to a certain degree, also other power outlets down the line from it in that circuit. This MOV, after a couple of years WILL fail, it is not a question of IF but WHEN. So always when possible, and you are creating your own circuit, use a larger size MOV, do not penny-pinch. Get a 20mm one if you can use it with the same characteristics, as it will last much longer in the same environment.
For people wondering on how it protects other outlets, that is simple.
As an example, from your electrical box, the wire comes in to your kitchen, you have 4 GPO’s (general power outlets) in there, if it is attached to the 1st outlet, and there is a lightning strike, it will first meet the outlet with the surge protection on, and “arrest” it, hence protecting the other items up to a certain degree in the remaining power outlets that follow. If it is at the last one, well, then it protects the outlet it is in.
Now, a good thing to do, is to put Surge Protectors in the GPO’s where you have your washing machine, Air Con and fridges connected to, as this will limit the surges sent back in to the electrical wiring of the house in to sensitive electronics like TV’s, Computers etc, although they do have most of the times a MOV in them, they use the 10 – 12 mm most of the time and they get worn out quickly, within a couple to a few years time.

Take care everyone.

Also , a Good practice is to use MOV like this: L-N, L-E, N-E, and also to have a fuse in series and a GDT if you want extra safety.

Reply
Swagatam says:
July 20, 2022 at 6:28 pm

Thank you, and Glad you found my designs helpful!
For 275 AC the peak voltage will be 390 V, so the MOV clamping voltage must be rated at 390 V.
Sorry, I haven’t yet investigated thermal fuses, so I do not have a the details about their working principle.

Reply
Cristi says:
July 20, 2022 at 11:51 am

Hi there, I also like very much your designs, and I have used some 🙂
I have a question here, I want to build a surge protection for an AC unit (230v in my country), and I live in an area where the voltage fluctuates a lot. I’m not sure if a 400v MOV would protect the electronics, I’m thinking max 275V. Am I correct? Also, since an iTMOV takes 12 weeks delivery time(and I need some feedback that it is no longer working) I would put in series a thermal fuse with a standard MOV. Can you provide an example calculation for the temperature or the fuse? Thank you.

Reply
Swagatam says:
June 17, 2022 at 4:46 pm

OK, then you can use a 400V MOV at the input side of AC 240V

Reply
Jose mavunkal says:
June 17, 2022 at 2:00 pm

Sir .max voltage is 240v ac and output 220-240v ac sine wave – load is 500watts also explain the connection method of mov

Reply
Swagatam says:
June 17, 2022 at 9:27 am

Jose, MOVs are placed only at the input side of an AC source. I can suggest the MOV values only if you can tell me the peak voltage value of your inverter input/output voltages.

Reply
View Older Comments

Need Help? Please Leave a Comment! We value your input—Kindly keep it relevant to the above topic! Cancel reply

Your email address will not be published. Required fields are marked *

Primary Sidebar

circuit simulator image



Subscribe to get New Circuits in your Email



Categories

  • Arduino Projects (93)
  • Audio and Amplifier Projects (133)
  • Automation Projects (17)
  • Automobile Electronics (101)
  • Battery Charger Circuits (85)
  • Datasheets and Components (109)
  • Electronics Theory (149)
  • Energy from Magnets (27)
  • Games and Sports Projects (11)
  • Grid and 3-Phase (20)
  • Health related Projects (27)
  • Home Electrical Circuits (13)
  • Indicator Circuits (16)
  • Inverter Circuits (95)
  • Lamps and Lights (159)
  • Meters and Testers (71)
  • Mini Projects (28)
  • Motor Controller (68)
  • Oscillator Circuits (28)
  • Pets and Pests (15)
  • Power Supply Circuits (91)
  • Remote Control Circuits (50)
  • Renewable Energy (12)
  • Security and Alarm (64)
  • Sensors and Detectors (106)
  • SMPS and Converters (34)
  • Solar Controller Circuits (60)
  • Temperature Controllers (43)
  • Timer and Delay Relay (49)
  • Voltage Control and Protection (42)
  • Water Controller (36)
  • Wireless Circuits (30)





Other Links

  • Privacy Policy
  • Cookie Policy
  • Disclaimer
  • Copyright
  • Videos
  • Sitemap



People also Search

555 Circuits | 741 Circuits | LM324 Circuits | LM338 Circuits | 4017 Circuits | Ultrasonic Projects | SMPS Projects | Christmas Projects | MOSFETs | Radio Circuits | Laser Circuits | PIR Projects |

Social Profiles

  • Twitter
  • YouTube
  • Instagram
  • Pinterest
  • My Facebook-Page
  • Stack Exchange
  • Linkedin



Recent Comments

  • Swagatam on 9 Simple Solar Battery Charger Circuits
  • Gagana on 9 Simple Solar Battery Charger Circuits
  • Swagatam on Arduino 2-Step Programmable Timer Circuit
  • Swagatam on Simple Buck-Boost Converter Circuits Explained
  • Swagatam on IC IR2111 H-Bridge MOSFET, IGBT Driver IC: Full Datasheet, Circuit Diagram

© 2026 · Swagatam Innovations