MPPT stands for maximum power point tracker, which is an electronic system designed for optimizing the varying power output from a solar panel module such that the connected battery exploits the maximum available power from the solar panel.

Introduction

NOTE: The discussed MPPT circuits in this post do not employ the conventional control methods like "Perturb and observe", "Incremental conductance, "Current sweep", "Constant voltage"......etc etc...Rather here we concentrate and try implementing a couple of basic things:

  1. To make sure that the input "wattage" from the solar panel is always equal to the output "wattage" reaching the load.
  2. The "knee voltage" is never disturbed by the load and the panel's MPPT zone is efficiently maintained.

What's Knee Voltage and Current of a Panel:

Put simply, the knee voltage is the "open circuit voltage" level of the panel, while the knee current is the "short circuit current" measure of the panel at any given instant.

If the above two are maintained as far as possible, the load could be assumed to be getting the MPPT power throughout its operation.

Before we Delve into the Proposed Designs, let's first get acquainted with some of the basic facts regarding solar battery charging

We know that the output from a solar panel is directly proportional to the degree of the incident sunlight, and also the ambient temperature. When the sun  rays are perpendicular to the solar panel, it generates the maximum amount of voltage, and deteriorates as the angle shifts away from 90 degrees  The atmospheric temperature around the panel also affects the efficiency of the panel, which falls with increase in the temperature.

Therefore we may conclude that when the sun rays are near to 90 degrees over the panel and when the temperature is around 30 degrees, the efficiency of the panel is toward maximum, the rate decreases as the above two parameters drift away from their rated values.

The above voltage is generally used for charging a battery, a lead acid battery, which in turn is used for operating an inverter. However just as the solar panel has its own operating criteria, the battery too is no less and offers some strict conditions for getting optimally charged.

The conditions are, the battery must be charged at relatively higher current initially which must be gradually decreased to almost zero when the battery attains a voltage 15% higher than its normal rating.

Assuming a fully discharged 12V battery, with a voltage anywhere around 11.5V, may be charged at around C/2 rate initially (C=AH of the battery), this will start filling the battery relatively quickly and will pull its voltage to may be around 13V within a couple of hours.

At this point the current should be automatically reduced to say C/5 rate, this will again help to keep the fast charging pace without damaging the battery and raise its voltage to around 13.5V within the next 1 hour.

Following the above steps, now the current may be further reduced to C/10 rate which makes sure the charging rate and the pace does not slow down.

Finally when the battery voltage reaches around 14.3V, the process may be reduced to a C/50 rate which almost stops the charging process yet restricts the charge from falling to lower levels.

The entire process charges a deep discharged battery within a span of 6 hours without affecting the life of the battery.

An MPPT is employed exactly for ensuring that the above procedure is extracted optimally from a particular solar panel.

A solar panel may be unable to provide high current outputs but it definitely is able to provide with higher voltages.

The trick would be to convert the higher voltage levels to higher current levels through appropriate optimization of the solar panel output.

Now since the conversions of a higher voltage to higher current and vice versa can be implemented only through buck boost converters, an innovative method (although a bit bulky) would be to use a variable inductor circuit wherein the inductor would have many switchable taps, these taps may be toggled by a switching circuit in response to the varying sunlight so that the output to the load always remains constant regardless of the sun sunshine.

The concept may be understood by referring to the following diagram:

Circuit Diagram

homemade MPPT circuit with tapped transformer

 Using LM3915 as the Main Processor IC

The main processor in the above diagram is the IC LM3915 which switches its output pinout sequentially from the top to the bottom in response to the diminishing sun light

These outputs can be seen configured with switching power transistors which are in turn connected with the various taps of a ferrite single long inductor coil.

The lower most end of the inductor can be seen attached with a NPN power transistor which is switched at around 100kHz frequency from an externally configured oscillator circuit.

The power transistors connected with the outputs of the IC switch in response to the sequencing IC outputs, connecting the appropriate taps of the inductor with the panel voltage and the 100kHz frequency.

This inductor turns are appropriately calculated such that its various taps become compatible with the panel voltage as these are switched by the IC output driver stages.

Thus the proceedings make sure that while the sun intensity and the voltage drops, it's appropriately linked with the relevant tap of the inductor maintaining almost a constant voltage across all the given taps, as per their calculated ratings.

So I have explained the functioning with the help of the following scenario:

Suppose the coil is selected to be compatible with a 30V solar panel, therefore at peak sunshine let's assume that the upper most power transistor is switched ON by the IC which subjects the entire coil to oscillate, this allows the entire 30V to be available across the extreme ends of the coil.

Now suppose the sunlight drops by 3V and reduces its output to 27V, this is quickly sensed by the IC such that the first transistor from the top now switches OFF and the second transistor in the sequence switches ON.

The above action selects the second tap (27V tap) of the inductor from top executing a matching inductor tap to voltage response making sure that the coil oscillates optimally with the reduced voltage...similarly, now as the sunlight voltage drops further the respective transistors "shake hands" with the relevant inductor taps ensuring a perfect matching and efficient switching of the inductor, corresponding to the available solar voltages.

Due to the above matched response between the solar panel and the switching buck/boost inductor...the tap voltages over the relevant points can be assumed to maintain a constant voltage through out the day regardless of the sunlight situation....

For example suppose if the inductor is designed to produce 30V at the topmost tap followed by 27V, 24V, 21V, 18V, 15V, 12V, 9V, 6V, 3V, 0V across the subsequent taps, then all these voltages could be assumed to be constant over these taps regardless of the sunlight levels.

Also please remember that these voltage can be altered as per user specs for achieving higher or lower voltages than the panel voltage.

The above circuit can also be configured in the flyback topoogy as shown below:

simple flyback MPPT design

In both the above configurations, the output is supposed to remain constant and stable in terms of voltage and wattage regardless of the solar output.

Using I/V Tracking Method

The following circuit concept ensures that the MPPT level of the panel is never disturbed drastically by the load.

The circuit tracks the MPPT "knee" level of the panel and makes sure that the load is not allowed to consume anything more which might cause a dropping in this knee level of the panel.

I have explained how this can can done using a simple single opamp I/V tracking circuit.

Please note that the designs which are without a buck converter will never be able to optimize the excess voltage into equivalent current for the load, and might fail in this regard, which is considered as the crucial feature of any MPPT design.

A very simple yet effective MPPT type device can be made by employing a LM338 IC and an opamps.

In this concept which is designed by me, the op amp is configured in such a way that it keeps recording the instantaneous MPP data of the panel and compares it with the instantaneous load consumption. If it finds the load consumption exceeding this stored data, it cuts off the load...

simple MPPT knee voltage tracker and self adjust


The IC 741 stage is the solar tracker section and forms the heart of the entire design.

The solar panel voltage is fed to the inverting pin2 of the IC, while the the same is applied to the non-inverting pin3 with a drop of around 2 V using three 1N4148 diodes in series.

The above situation consistently keeps the pin3 of the IC a shade lower than pin2 ensuring a zero voltage across the output pin6 of the IC.

However in an event of an inefficient overload, such as a mismatched battery or a high current battery, the solar panel voltage tends to get pulled down by the load. When this happens pin2 voltage also begins dropping, however due to the presence of the 10uF capacitor at pin3, its potential stays solid and does not respond to the above drop.

The situation instantly forces pin3 to go high than pin2, which in turn toggles pin6 high, switching ON the BJT BC547.

BC547 now immediately disables LM338 cutting off the voltage to the battery, the cycle keeps switching at a rapid pace depending upon the IC's rated speed.

The above operations make sure that the solar panel voltage never drops or gets pulled down by the load, maintaining an MPPT like condition throughout.

Since a linear IC LM338 is used, the circuit could be yet again a bit inefficient....the remedy is to replace the LM338 stage with a buck converter...that would make the design extremely versatile and comparable to a true MPPT.

Below shown is an MPPT circuit using a buck converter topology, now the design makes a lot of sense and looks much closer to a true MPPT

MPPT with tracker and self optimizing buck power supply

48V MPPT Circuit

The above simple MPPT circuits can be also modified for implementing high voltage battery charging, such as the following 48V battery MPPT charger circuit.

60V to 24V MPPT tracker design

The ideas are all exclusively developed by me.

You'll also like:

  • PIR controlled automatic solar garden light circuitPIR Controlled Solar Garden Light Circuit
  • iv curve tracker circuit 1I/V Tracker Circuit for Solar MPPT Applications
  • AlternatorPowerBooster5B15DGenerator/Alternator AC Voltage Booster Circuit
  • mpptIVgraphUnderstanding MPPT Solar Charger

Filed Under: Solar Controller Circuits Tagged With: Homemade, Maximum, MPPT, Poor, Power, Solar

About Swagatam

I am an electronics engineer and doing practical hands-on work from more than 15 years now. Building real circuits, testing them and also making PCB layouts by myself. I really love doing all these things like inventing something new, designing electronics and also helping other people like hobby guys who want to make their own cool circuits at home.

And that is the main reason why I started this website homemade-circuits.com, to share different types of circuit ideas..

If you are having any kind of doubt or question related to circuits then just write down your question in the comment box below, I am like always checking, so I guarantee I will reply you for sure!

Previous Post: « 3-Step Automatic Fast Battery Charger/Controller Circuit
Next Post: 3 Simple Solar Panel/Mains Changeover Circuits »

Reader Interactions

Comments

Emmanuel Offiong says:
July 13, 2021 at 9:35 pm

Sir I mean the fourth circuit that is using 555timer IC and single opamp IC, this circuit is not working and you didn’t make any explanation for this circuit.

Reply
Swagatam says:
July 14, 2021 at 8:52 am

Emmanuel, the IC 555 circuit is a complex circuit and you must build it with step step up testing and by understanding the stages perfectly. If you do it without understanding it then it will never work.

First confirm the op amp stage using meters and the explanation provided in the above article.

Once the op amp stage is confirmed then you can build the buck converter stage.

For understanding the 555 buck converter you will have to first learn how a buck converter works.

If I possible I will add the explanation soon for the 555 buck converter.

Reply
Emmanuel Offiong says:
July 3, 2021 at 8:57 pm

You have not explained anything on the working principles under the MPPT circuit diagram please kindly do that for me sir.

Reply
Swagatam says:
July 4, 2021 at 10:15 am

The circuit works using the standard step down transformer principle. The circuit adjusts the transformer tapping with the solar panel voltage and matches them appropriately, so that the right winding gets the right voltage from the solar panel. When this happens the output voltage remains constant, and also output current remains optimally adjusted regardless of the solar panel voltage

Reply
Onyi Ernest says:
June 24, 2021 at 3:27 am

Thank you sir.
What will happen if a bulk converter is connected directly to Solar panel and then to load without mppt.?

Reply
Swagatam says:
June 24, 2021 at 8:06 am

Hi Onyi, Buck converter will work very nicely almost like an MPPT, but you must have an over charge auto cut off for the battery, to prevent over charging

Reply
David Santos says:
June 23, 2021 at 7:22 am

do you have diagram for 80 amps MPPT? Thanks in advance.

Reply
Swagatam says:
June 23, 2021 at 10:39 am

sorry I don’t have it at this moment….

Reply
Adithya says:
June 12, 2021 at 11:49 pm

Hi Swagatam,
Really excited to find this!!
Just one clarifcation, can we charge Lithium ion or LiFePO4 battery. If so please provide specification.

Reply
Swagatam says:
June 13, 2021 at 3:10 pm

Thank you Adithya, yes definitely you can charge Li-ion or LiFePO4 battery with the above MPPT. For charging these batteries you can use the circuit explained in the following article, just make sure to use a current that’s 50% less than the mAh value of the battery

USB 3.7V Li-Ion Battery Charger Circuit

Reply
Engr. Bayo (Bash Inverters) says:
April 1, 2021 at 4:56 am

Hello Engr. Swag.
Many thanks for your selfless and invaluable efforts in throwing out for free and demystifying top secret in electronics which other Engineers would have converted into money.
Could you give me a simple 12v mppt based charge controller circuit, as updated.
Thanks.

Reply
Swagatam says:
April 1, 2021 at 12:36 pm

Thank you Engr Bayo, a simple MPPT circuit created by me is shown in the above article (second diagram) which will give you 100 % working results using ordinary components.

Reply
Joe Brands says:
May 10, 2021 at 1:20 am

Hi Swagatam,
Please can you shed more light on the type of ferrite single long inductor coil used in the diagram? And what is the value of the capacitor in the output?
What is the current output rating of the circuit ( Number 2 diagram)?

Reply
Swagatam says:
May 10, 2021 at 8:07 am

You will have to find it through some trial and error, you can use 1.25 times the input voltage initially and tweak the turns with the help of a voltmeter attached to the output taps.

Reply
Darrell says:
January 11, 2021 at 8:21 am

This is excellent reading. Thank you

Reply
Lins Roberto Pereira, says:
December 26, 2020 at 12:32 am

MERRY CHRISTMAS, AND A LOT OF STRENGTH IN 2021. IN THIS LAST CIRCUIT, I INTEND TO USE TWO PANELS THAT ADD, ARE 70 VOLTS AND 9 AMPERE, FOR FOUR BATTERIES 12 VOLTS IN SERIES. BEING SO I HAVE TO CONNECT A THICK WIRE, THAT LEADS 9 AMPERE IN TIP 147, IS IT REALLY?

Reply
Swagatam says:
December 26, 2020 at 2:43 pm

Merry Christmas to you and also wishing a happier and a safer 2021 to you.
You can definitely try the last circuit for your application.
However, TIP147 might not be sufficient to handle 9 amps….you can instead replace the TIP with a IRF9540 MOSFET, it will do the job for you perfectly.

Reply
Lins Roberto Pereira, says:
December 29, 2020 at 12:18 am

THANKS. BUT DOES THE 1K RESISTOR CONTINUE THE SAME? THANKS.

Reply
Swagatam says:
December 29, 2020 at 11:52 am

For a MOSFET the 1k can be any value, it is immaterial. For transistor it will need to be calculated using the for a as explained in the following article

Transistor Relay Driver Circuit with Formula and Calculations

Reply
Lins Roberto Pereira, says:
November 24, 2020 at 4:48 am

HELLO HOW ARE YOU? THIS 48V CIRCUIT AND 60 V PANEL, CAN I USE 4 12V BATTERIES IN SERIES, BUT WITH A 75V AND 9 AP PANEL, APPROXIMATELY? WHAT SHOULD I MODIFY?

Reply
Swagatam says:
November 25, 2020 at 9:49 am

Hi, yes definitely, you can use the last circuit from the above article to charge your 48V battery from a 75V panel

Reply
Joseph says:
August 11, 2020 at 1:31 am

Pls is there any other MPPT circuit for 60amps/24v?

Reply
Swagatam says:
August 11, 2020 at 10:41 am

Sorry, presently I do not have a 60 amp design

Reply
Loseph says:
August 9, 2020 at 2:40 am

Pls Mr swag,I need complete through 60amps 24v MPPT controller.Which of your article can be used and what modifications is needed?

Reply
Swagatam says:
August 9, 2020 at 12:23 pm

You can try the concept explained in the above article (1st design) but for 60 amps the transformer will be huge, unless it is a ferrite based design

Reply
David Lee says:
June 16, 2020 at 3:43 am

Swagatam, Thank you for you ideas and suggestions

Reply
Swagatam says:
June 16, 2020 at 7:56 am

Glad to help!

Reply
David Lee says:
June 15, 2020 at 4:23 pm

I am looking to make a MPPT to power the electrodes in a salt water swimming pool chlorinator. The pump is 72volt DC and runs direct off the panels via its own MPPT. – no battery. Using a 12 volt panel(s) would like to feed straight to the electrodes in the chlorinator unit. The electrodes need 8-12volts at a current of 15-20 amps. Would one of your MPPT circuits be able to achieve this without the battery connection? The MPPT can be switched on by a flow switch situated in the pump supply or discharge line. (the pump is in flood so water will flow the second the pump starts)

Reply
Swagatam says:
June 15, 2020 at 8:13 pm

The inductor based MPPT explained might surely work, however the high frequency transformers are not calculated, and using an iron core trasformer might make the design huge and bulky.

Instead I would recommend using professional and tested buck converter designs which should work as efficiently as an MPPT if the load is not exceeded above a specified level. Here are a few examples:

LM317 Variable Switch Mode Power Supply (SMPS) You may have to upgrade the transistor Q1 value to support 10 to 15 amps

PWM Solar Battery Charger Circuit The resistors R8/R9 should be adjusted for getting a 12 V output.

https://www.ti.com/lit/ds/symlink/lm5145.pdf?ts=1592229037795&ref_url=https%253A%252F%252Fwww.ti.com%252Fproduct%252FLM5145

Reply
Abbey says:
February 24, 2020 at 6:13 pm

Hello sir, please help me with the formula to calculate the number of turns and amperage of the above 2 mppt transformers. Thanks Abbey.

Reply
Swagatam says:
February 25, 2020 at 7:48 am

Abbey, you can use the second concept from top, it uses an ordinary iron core transformer having multiple primary taps, 3V,4.5V, 6V…..24V and so on. The secondary output could be 220V, for low voltage output, you can extract them across the primary taps itself.

Reply
Abbey says:
February 25, 2020 at 1:48 pm

Good morning Mr Swagatam, I really appreciate your character of been prompt to reply every questions sent to you, thanks a lot and have a nice day. Abbey.

Reply
Swagatam says:
February 25, 2020 at 6:37 pm

You are welcome Abbey!

Reply
Drew says:
April 25, 2019 at 2:14 am

Each of the outputs of the LM3915 acts simply as a switch that flips when the input voltage from the panel crosses the threshold defined for that op-amp by the IC’s internal resistors. All the outputs from the IC generate the same voltage, so all the BJT’s gate at the same voltage, and the resistors between the BJT’s and the IC are the same as well. Could you accomplish the same effect by using a single op-amp, configured for a precise, low gain, and pairing each BJT with two resistors of precise values, as a voltage divider, chosen to admit the voltage necessary to gate that BJT only when the amp is receiving current from the panel at a particular voltage?

Reply
Swagatam says:
April 25, 2019 at 9:13 am

In the above concept, the main MPPT execution is done by the transformer through the matching of its various taps with the solar voltage.

The PNP only act as switches that’s correct, and the IC matches the solar voltage appropriately with the most relevant tap of the transformer through the PNP switches, as per a predetermined setting.

With a single opamp we cannot switch the different taps of the transformer and therefore cannot accomplish the required MPPT effect.

Reply
annamalai says:
April 15, 2019 at 7:13 pm

sir we have 240 battery bank we need 240 volt mppt Gharge controler circuit idyas in ower solar panel open volt is 360

Reply
Swagatam says:
April 15, 2019 at 8:58 pm

Hello annamalai, you can try implementing the first two simple concepts explained above, the transformer winding can be modified as per your charging specifications

Reply
Drew says:
April 10, 2019 at 11:54 am

As I understand it, the LM3915 contains a voltage reference, ten op-amps, and various resistors used as voltage dividers, such that it switches among outputs with varying input voltage. As shown in the first illustration, it gates the TIP127’s to direct current from the panel through the best-suited length of inductor coil according to incident voltage. But the differences in magnitude between the outputs of the LM3915 are inherent to the design – they can’t be changed by the user, so the connections to the inductor have to be placed carefully to match them. Could the efficiency of the design be improved by placing the inductor taps at regular intervals – or using discrete inductors in series – and replacing the LM3915 with discrete components, chosen carefully to match the inductance values of each connection to the inductor? If so, could the efficiency be improved further by adding a greater number of outputs, with smaller differences between them?

Reply
Swagatam says:
April 10, 2019 at 2:16 pm

Yes the output will sequence at uniform steps in response to the corresponding increase or decrease in the solar voltage. WE can note down at what input voltages the output shifts, and accordingly dimension the coil data, so that the two operations become compatible with each other. Alternatively we could go for discrete opamp based sensor, as used in this concept:

https://www.homemade-circuits.com/5-kva-to-10-kva-automatic-voltage-stabilizer-circuit-220-volts-120-volts/

Reply
Drew says:
April 10, 2019 at 10:35 pm

What’s the advantage of discrete op-amps? Would it become more efficient if you used more steps?

Reply
Swagatam says:
April 11, 2019 at 8:35 am

discrete opamp will allow us to adjust the changeover thresholds as per our desired specs. LM3915 will do as per its own fixed specs, and this will be uniform across the whose range…I think LM3915 is a better option

Reply
matt says:
March 2, 2018 at 8:24 pm

good day Eng Swag,
please do you have any solar mppt circuit diagram that can output upto 300vdc with input between 200-300vdc?
thanks

Reply
Swagatam says:
March 3, 2018 at 8:54 am

Matt, I only have a buck converter based MPPT, I do not have a buck-boost based design yet

Reply
Shedrach says:
October 26, 2017 at 4:08 pm

Hello sir,please may explain a difficulty and ask a question based on it.based on the first and second diagrams.that is the buck/boost configuration.I checked online for awg wire current and frequency rating and found that the thickest wire to operate at 100khz with 100% skin depth is awg26.but this wire is able to carry only 0.361amp .so to get 5amps we will need to wound 15 wires together,meaning one will deal with 30 wires at each tap. The question is”can the circuit be operated at a lower frequency”? Say 8-40khz. Which will allow the use of awg15-22. Reducing wire to 1-5

Reply
Swagatam says:
October 26, 2017 at 4:45 pm

Hi Shedrach, It seems you might have missed something, your analysis might be wrong. frequency is related with number of turns, not with wire AWG or thickness. However number of turns is related to current, more turn numbers allow less current and vice versa.

at higher frequencies the turns number decreases proportionately and vice versa, therefore at higher frequencies number of turns become less allowing smaller inductors to be used.

you can use any transformer by suitably matching the frequency specs, but lower frequency will mean incorporating bigger transformers and bulkier installation.

Reply
Swagatam says:
October 26, 2017 at 4:48 pm

for improving skin depth you can use stranded type copper wire having many bifilar wires compacted together.

Reply
Swagatam says:
October 26, 2017 at 4:54 pm

you can find the wire thickness required for 5 amp at 100kHz, then use stranded wire for that thickness to make things easier and efficient, for example if the required thickness is 14 AWG, we can use stranded 14 AWG wire and effectively minimize the volume of the transformer

Reply
adam says:
October 21, 2017 at 9:14 pm

Sir I want to convert 60v DC to 12v DC…please Help.. 60v is solar panel.

Reply
Swagatam says:
October 22, 2017 at 12:27 pm

you can try the following circuit

https://www.homemade-circuits.com/lm317-variable-switch-mode-power-supply/

Reply
Abbey says:
February 20, 2020 at 1:45 am

Please Sir, can someone use laminated transformer (I E) type for the mppt discussed above? Thanks Abbey.

Reply
Swagatam says:
February 20, 2020 at 8:17 am

Abbey, yes iron core transformer can be used for the above discussed concept.

Reply
adam says:
October 21, 2017 at 9:13 pm

plz ..your link iz not working …..not found
Sir I want to convert 60v DC to 12v DC…please Help.. 60v is solar panel.

Reply
Swagatam says:
October 22, 2017 at 11:56 am

which link is not working??

Reply
ubaid khan says:
September 29, 2017 at 12:29 pm

Sir I want to convert 60v DC to 12v DC…please Help.. 60v is solar panel.

Reply
Manoj pandey says:
August 31, 2017 at 11:59 am

Dear sir,

Please send me 48 volt only low dc cut off circuit

Reply
Manoj pandey says:
August 31, 2017 at 12:31 pm

Dear sir,

Input dc voltage 48volt so, please advice provided circuit is working correctly and how to adjust voltage

Reply
Swagatam says:
August 31, 2017 at 12:39 pm

Hi Manj,
you can use the same circuit for 48V also, just make sure the relay is 48V rated, and use BC546, BC556 instead of BC547, BC557

apply the specified low voltage level from the battery side, and adjust the preset such that the relay just clicks ON….that’s all.

now if you increase the voltage, the relay will switch OFF, but the margin could be around 2 to 3V

Reply
Manoj pandey says:
August 31, 2017 at 1:29 pm

Dear sir

Please provide the 48v to 12v DC to DC converter circuit if using lm 317 or 7812

Reply
Manoj pandey says:
September 1, 2017 at 8:26 am

Dear sir,

Please provide AC to dc 12 volt without transformer circuit

Reply
Swagatam says:
September 1, 2017 at 12:35 pm

you can try this

https://www.homemade-circuits.com/2015/01/calculating-capacitor-current-in.html

Reply
Manoj pandey says:
September 1, 2017 at 6:41 am

Dear sir,

Thanks for reply but my requirement is only 5 to 10 second timer circuit so please provide

Reply
Swagatam says:
September 1, 2017 at 7:16 am

you can reduce R2, C1 value to get the desired timing delay.

Reply
Manoj pandey says:
August 31, 2017 at 2:24 pm

Dear sir,

Please provide the 5 second delay timer circuit using ic 555 and operated 12 volt really if on the switch.than start circuit
(Input voltage 12v)

Reply
Swagatam says:
September 1, 2017 at 4:26 am

Manoj,

you can try the following design

https://www.homemade-circuits.com/2014/06/input-trigger-synchronized-monostable.html

put the push button at the points shown as “left pin”

Reply
Swagatam says:
August 31, 2017 at 2:10 pm

Dear Manoj, you can try the following design

https://www.homemade-circuits.com/2016/08/0-60v-lm317-variable-power-supply.html

Reply
Swagatam says:
August 31, 2017 at 12:20 pm

Dear Manoj,

you can try the last design from this post

https://www.homemade-circuits.com/2013/05/low-battery-indicator-circuit-using-two.html

Reply
Imran Ahmad says:
November 15, 2016 at 6:24 am

Hello sir!
i am a student of B.tech electrical. i am working on my final year project. Sir i want to make an MPPT Charge controller of rating 200 watt panel. kindly sir guide me how can i make this without using the microcontroller. some suitable circuit diagram. plzzz sir.i have seen many articles of mppt of yours. butt i am confused. suggest me the best suitable diagram of my rating. your help will be highly appreciated.

Reply
Imran Ahmad says:
November 25, 2016 at 6:27 am

Thank you so much Sir!

Reply
Swagatam says:
November 15, 2016 at 1:41 pm

Hello Imran,

You can try the following concept, if you build it correctly step wise it will solve your purpose

https://www.homemade-circuits.com/2015/11/simple-solar-mppt-circuit-part-2.html

Reply
Mohammad Uzair says:
March 9, 2016 at 9:50 am

Hi.Sir Swagatam Majumdar.Sir we are working on Perturb and observe method.Can u provide me with a working dc-dc converter circuit diagram.Range having input 8-20 volts and output range 9-22.thanks

Reply
Swagatam says:
March 10, 2016 at 10:56 am

Hi Mohammed, I have not yet researched this concept, if possible I'll do it and try to design a suitable circuit with this concept.

Reply
Zoltán Karner says:
November 5, 2015 at 7:51 pm

This is NOT an MPPT controller!!!!!!!!!!!!

Reply
Tando Soomro says:
April 29, 2015 at 10:41 am

I have 200 watts solar panel and i want to build mppt solar charge controller, please send me circuit diagram and component list.

Reply
Swagatam says:
April 30, 2015 at 8:06 am

you can refer to the following concept:

https://www.homemade-circuits.com/2014/11/self-optimizing-solar-pwm-charger.html

and also read this:

https://www.homemade-circuits.com/2015/04/mppt-solar-tracker-difference.html

Reply
Mooney M. says:
March 19, 2015 at 9:26 am

Another quick question please. In the schematic for the 48v version, isn't the 78L12 receiving excessive voltage from the 60V solar panel?

Reply
Swagatam says:
March 19, 2015 at 12:45 pm

yes you are right, a 78XX will not work here, you can replace it with the common collector stage as shown in the second last circuit above…using the BC547 and its base zener diode/resistor design

Reply
Mooney M. says:
March 19, 2015 at 5:15 am

Dear Swagatam,

Thank you for providing such brilliant guidance. I am designing a 48v charge controller to hook up with the 200 AH battery bank. The panels array is rated approx. 2000 watts. The batteries are attached to a 3kw ups. This arrangement mainly runs a air conditioner (1200 watts) in summers. Therefore the amps flowing through the system are a lot (2kw@48v). I had a charge controller of 50 amps which is now broken and it costs around 150 usd. I don't plan on buying a new one. Instead I'm going to use your circuits with some modifications like mechanical on/off switches and additional transistor stages to pass all that power. Or perhaps replace the transistors with heavy duty triacs or even high amp car relays in parallel. My question is if I will be able to drive many transistors from the pin 6 of the 741 ic. Is there a circuit simulation software I can use first? Like a spice variant which has IC packages like 741 and 555 that I can employ to test the whole thing? Sorry for so many questions but sensing that you are a noble person who likes to help others I thank you in anticipation for your guidance. Stay blessed.

Reply
Swagatam says:
May 31, 2015 at 6:09 am

Mooney, you can try the following circuit:

https://www.homemade-circuits.com/2015/05/5v-pwm-solar-battery-charger-circuit.html

Reply
Mooney M. says:
May 30, 2015 at 5:52 pm

Still waiting for the update. Bro Majumdar its not so necessary to make it mppt. It just needs to be efficient. Its meant for poor people any way. A full bridge buck converter that can handle the amps and its limits governed by a few ICs may as well do the trick.

Reply
Swagatam says:
April 4, 2015 at 12:27 pm

Sure Bro! I am always ready to help! However the above circuits were built on an mistaken assumption…so it wouldn't be a good idea to try these circuits won't simulate an MPpT, In my previous comment I suggested you an alternative circuit I would recommend you to try that instead of the above.

Or you can also try the earlier link that I had referred using IC 555 IC.

I would be updating the article soon with a correct version so that the circuits works more like an MPpT.

Reply
Mooney M. says:
April 4, 2015 at 8:03 am

Brother forgive me but kindly do me this one favor only, modify the 48 volt circuit on this very page only to handle 2 kilo watts of power. The more I read about drive requirements for transistors and mosfets the more I feel ignorant about them. You're the guru so please guru ustad take the time to make this small modification. I will acquire the PNP transistors and everything else. This one here, aptly named Poor man's mppt is the best of them all when it comes to simplicity and efficiency.

Reply
Swagatam says:
April 1, 2015 at 5:19 am

Sorry bro, you cannot use relays here, because the switching is supposed to be very rapid, either a mosfet or a transistor will only work for the above circuits.

for the time being you could rather try building the last design from the following article, I would recommend this one as its much easier and makes more sense:

https://www.homemade-circuits.com/2013/08/simple-zero-drop-solar-charger-circuit.html

Reply
Mooney M. says:
April 1, 2015 at 12:02 am

Okay thank you Swagatam, I'll be looking forward to it. In the mean time, I think I am going to build the circuit on this page and instead of a transistor I'm going to use a bunch of car relays driven by the 741. I hope the IC will not be switching them too much because I do not want the inductive kickback spikes from fast switching relays to damage the UPS. Am going to start building this ASAP. I intended to send you report and photos of any build designed by you so I will send you photos of it, hopefully.

Reply
Swagatam says:
March 31, 2015 at 8:02 am

Thanks bro, for the nice explanation, I'll try to design and publish the required circuit, specific to your application. It may take some time though, since it would be quite an elaborate article and might take a lot of thinking…..

cheers!.

Reply
Mooney M. says:
March 30, 2015 at 1:03 pm

It is, and I hate to whine to you but it uses a P channel mosfet. Being rare (for some reason), P channel power mosfets are expensive over here, like a dollar for one. Then, I am located far away living on a farm in remote Punjab. I have plenty of n channel mosfets and transistors though and the usual items like 555's, 324's, 741s, and a whole lot of scrap including transformers from local made UPS units.

The other concern I have is that internet searches bring forth the advanced concepts like H bridge and full bridge mosfets driven by the latest ICs which I do not have. I could try and hunt for 3524 or other PWM and FET driving ICs. But the coolest idea of a 555 based PWM driving mosfets and "chopping" the power coming down from the solar panels and tailoring it to my need seems most feasible to me for now.

I have made simulations of all the circuits you have developed, all of them, however they don't simulate very well because the applet I'm using, developed by Paul Falstad, does not have a PV input. Otherwise the circuit you have shown here is quite good being simple. Secondly the PV array is 2 kilo watts of power. And I'm not sure how to add mosfets to share the power. To be honest, Mosfets are sophisticated things with a lot of "nakhra" to take care of in their design, as you know.

I could use a small army of D1047 NPN transistors instead if need be (I have plenty of these from scrap), driven by a 555 based PWM and a 741 or two as comparators, sensing and controlling the voltage limits as long as the circuit doesn't let them go linear to waste the power being conducted down. But I am a newbie so I'm not so confident in designing it. I also have a box full of IRFP150N n cannel mosfets.

Bro you agreed to help me. Perhaps you could take the time to design such a thing for me? Pretty please. My wife and children are visiting their parents and I want to get the solar power up and running by the time they return which is a week from now. And with all the frequent rains I don't have much outdoor farming work to do anyway. What do you say dear bro? 🙂

Reply
Swagatam says:
March 26, 2015 at 2:58 am

I know it bro, I thought you'd find it difficult to build the PWM version and therefore I referred a simpler option to you.

For the PWM version you can take a peek at this article, I think this is exactly what you may be looking for:

https://www.homemade-circuits.com/2014/11/self-optimizing-solar-pwm-charger.html

Reply
Mooney M. says:
March 25, 2015 at 9:45 am

The problem with transistors and linear regulation is waste of a lot of power. I don't want that bro. What I need is mosfets switching by pwm signal and not wasting power. Op amps can control the switching. If you google "the back shed mppt circuit" you will find what I have explained. Bro I need your kind consideration upon that one, please. Its gorgeous and succinct.

Reply
Swagatam says:
March 20, 2015 at 3:56 am

Thanks bro, the pleasure is all mine. yes the circuit can be made automatic simply by adding the following design with its output:

https://www.homemade-circuits.com/2012/08/make-this-48v-automatic-battery-charger.html

the circuit actually can be enhanced in many different ways, as per the user preferences.

Reply
Mooney M. says:
March 19, 2015 at 3:00 pm

I feel extremely grateful to read that you are willing to take the time to help me. And that you have replied so quickly. Thanks bro.

The 100 amp variable voltage power supply design that you have linked is simply amazing and new to me. I can't appreciate the idea enough. However that one is missing automatic feature of a cut off to end charging when battery voltage drops below a certain lower limit like 50 volts or so. 50 is lower than the standing voltage of the batteries and it'll mean that the UPS is loaded and drawing power from them. The potentiometer in the circuit seems useful to have and I hope to use it in order to raise the voltage going to the batteries manually, only once a month, and give them an equalizing charge.

Reply
Swagatam says:
March 19, 2015 at 12:38 pm

Thank you dear Mooney,

Actually I have never used a simulator in my life because I simply never needed these artificial means, I normally do the simulation in my mind much reliably…so I am afraid I have no idea about these things.

By the way if you say I could design the system for you, if you can specify the exact features that you would want the charger to include.

If you are interested to go for a simpler option here's one very simple circuit which will start charging your batteries as soon as you hook it up with the panels.

https://www.homemade-circuits.com/2015/03/100-amp-variable-voltage-power-supply.html

Reply
inayat kheshgi says:
March 13, 2015 at 1:31 pm

can I use this circut direct connect to load?
means the input of the circut connect to the output of the solar and the output of circut connect to 12v dc fan.
can this can work good?

Reply
Swagatam says:
March 14, 2015 at 10:57 am

yes it can be done……

Reply
inayat kheshgi says:
March 12, 2015 at 3:04 pm

if all the component connect same like the above circut but If dont use 10k preset with this circut what would be the result?
can work fine or not?

Reply
Swagatam says:
March 13, 2015 at 3:12 am

if your panel output is below 24V then the preset can be removed, otherwise the preset will be required.

Reply
inayat kheshgi says:
March 12, 2015 at 9:43 am

sir plz that one thing I dont understand 240E
or this is resistor?

Reply
Swagatam says:
March 13, 2015 at 3:11 am

it's a resistor = 240 ohms

Reply
Rishikesh Sharma says:
March 12, 2015 at 4:51 am

HI, instead of using solar panels, can i use external power source/supply with appropriate voltage to charge battery?

Reply
Swagatam says:
March 12, 2015 at 5:25 am

Hi, the above circuits are designed to work with solar panels only, for a mains powered power supply the above complex design may not be required, you can simply use any standard design from this page:

https://www.homemade-circuits.com/search/label/Battery%20Charger

Reply
inayat kheshgi says:
March 11, 2015 at 5:02 pm

I have 150w panel round about 30 to 35v can I use this circut
and how much time they full fill bettery(50ah).thanks

Reply
Swagatam says:
March 12, 2015 at 5:19 am

yes you can connect it.
it will be difficult to predict the battery charging time because it could depend on many external factors.

Reply
AJITH says:
March 5, 2015 at 3:45 pm

Sir,
I am build the ciruit, but the output voltage is around 35 v , what I do ?

Reply
Swagatam says:
March 6, 2015 at 8:15 am

Ajith, did you set the circuit as directed in the article.

connect an LED in series with the emitter of the transistor, and switch ON the 35V input

next, without connecting any battery first adjust the preset such that the voltage at pin2 is 12V,

without any load this LED should stay switched OFF.

Now short the output terminals, LEd should light up now.

confirm the above and let me know.

Reply
AJITH says:
February 24, 2015 at 4:55 pm

Sir,
U mean 48v mppt controller circuit ?
Which diode connected in series with panel ?

Reply
Swagatam says:
February 25, 2015 at 5:55 am

yes that's correct, use a 10amp diode with the panel.

Reply
AJITH says:
February 23, 2015 at 5:28 pm

Hai sir,
I have two 35v165w panel. Can u use this circuit for charging 12v 100AH Battey ?

Reply
Swagatam says:
February 24, 2015 at 7:28 am

Hi Ajith, you can try the last circuit which is the simplest one, make sure to add a 6V zener in series with the base of the transistor.

connect the panels in parallel.

Reply
jeffrey says:
January 19, 2015 at 2:59 pm

sir in your other pic for this project there is no trimmer atach

Reply
Swagatam says:
January 20, 2015 at 3:12 am

jeffery please provide me with the link, I'll check it out

Reply
Slide Pecson says:
January 13, 2015 at 10:23 am

Sir what is the value of the capacitor C in the middle of the circuit? its connected in the emitter of the BC547.

Reply
Swagatam says:
January 13, 2015 at 2:54 pm

slide, please click the diagram to enlarge it….you'll find it to be 220pF

Reply
Mayuresh Rao says:
December 16, 2014 at 2:29 pm

sir can u design the above solar charge controller for 48V 15A current level for MPPT tracking

Reply
Swagatam says:
December 17, 2014 at 4:49 am

Mayuresh, you can try the last circuit updated in the above article.

Reply
Swagatam says:
October 3, 2014 at 2:55 am

….and how would anybody charge a 100AH or a 200AH batt using LT3652

Reply
larzman says:
October 2, 2014 at 4:07 pm

your designed circuit is not a true MPPT circuit, as expressed by JD Bakker. You fault him, but your headline is for an MPPT controller, which the circuit is not. As we say in America, that's false advertising.

Rather than just criticize, I will point you to a solution. Review the simple MPPT controller based on the Linear Technology LT3652. Quite an easy circuit to construct, actually MUCH easier than yours. Maybe instead of getting defensive, you should look for a true solution. You could also provide instructions to help enhance output capacity (charge current).

Reply
belbecake cake says:
September 1, 2014 at 5:28 am

sir gud day,
thank you for your informative and helpful blog.
my some question is:
1.in R1,2,3 0.7ohms, how many watts i apply if my battery is 12v 40AH and my solar panel is 50w, 12v-20v. pls.. give me exact value of the resistor 1,2,3.
2.IC324 is it also LM324 if i buy in elect. store.
3.all 4 presets 10k parts under ic324 is it automatically set already or i manually configuring the value to set the right output, if manually do, will you mind how to set this in correct value.
Hope you appreciated me. Thanks very much!

Reply
Swagatam says:
September 1, 2014 at 2:17 pm

The above circuit procedures could be quite complicated for anyone who may new in the field, it's for the experts….I'll try to update the article soon with an identical design but using lesser number of components and hassle free setting procedures….so please keep in touch until then

Reply
surya kiran says:
April 1, 2014 at 2:41 am

Why that much high rating 10 amp diode is used?

Reply
Swagatam says:
April 2, 2014 at 5:53 am

So that bigger batteries upto 100ah can be charged, you can use smaller diodes suiting your requirements.

Reply
surya kiran says:
March 25, 2014 at 3:01 am

The ground points must be connected to battery -ve or solar panel – ve

Reply
Swagatam says:
March 25, 2014 at 3:12 pm

battery negative

Reply
surya kiran says:
March 25, 2014 at 2:56 am

Does it mean both the transistor emitter points should be connected

Reply
Swagatam says:
March 25, 2014 at 3:12 pm

yes.

Reply
surya kiran says:
March 24, 2014 at 11:01 am

i made the circuit,but my solar panel is giving 10 volts without mppt but when the mppt is connected only 6 volts is measured. I measured this 6v by taking away the battery and connected a multimeter in place of battery it showed 6 volts. how can maximum power can be obtained with reduced voltage.
i connected 3 w 9v solar pannel and 12v 1.3AH battery
and the red led is always glowing even when the battery is dischearging

Reply
Swagatam says:
March 25, 2014 at 1:24 pm

how can you charge a 12V batt with a 9v input?????

you will need a 18v panel for a 12v batt and the above circuit.

also replace the 4k7 pot under LM38 with a 10k pot for getting a 15V adjustable range

Reply
surya kiran says:
March 23, 2014 at 3:45 pm

Where the ground in the circuit conneted?

Reply
Swagatam says:
March 24, 2014 at 4:03 pm

transistor emitter lines need to be connected together

Reply
surya kiran says:
March 22, 2014 at 3:21 pm

How to set the 10k preset values explain briefly?

Reply
Swagatam says:
March 24, 2014 at 4:25 am

pls make the circuit first, then I'll explain it further.

Reply
surya kiran says:
March 14, 2014 at 4:29 am

when will the red and green led's glow?

Reply
Swagatam says:
March 14, 2014 at 3:37 pm

green = charging
red = batt full.

Reply
surya kiran says:
March 11, 2014 at 4:04 am

1) R1 R2 and R3 = 0.7/ charging rate in kilo ohms or ohms?
2) Is 4K7 is preset resistor?

Reply
Swagatam says:
March 11, 2014 at 4:00 pm

1) it's in Ohms.
2)4k7 can be a preset or a pot. It should be a 10k preset/pot actually

Reply
surya kiran says:
March 10, 2014 at 1:39 pm

In the circuit one transistor base is connected to 100 ohms and after that an a connection with big dot is left freely what to connect there?

Reply
Swagatam says:
March 11, 2014 at 6:49 am

ignore the dot, remove it from the circuit, it's a drawing mistake.

Reply
surya kiran says:
March 9, 2014 at 2:42 pm

hi!
thanks a lot in helping me in completing the dual axis solar tracker it's working perfectly
my next step is to connect the solar panel of dual axis solar tracker to this simple mppt circuit
is this idea good
Here in the circuit A3 and A4 are the other 1/2 of IC 324 then in circuit A3 is +v and ground connection are these connections pin 4 and 11 in IC 324?

Reply
Swagatam says:
March 10, 2014 at 8:24 am

I would recommend the simpler zero drop charger design which is shown below, it's basically a voltage regulator circuit that optimizes the solar parameters and avoids unnecessary loading of the panel.

https://www.homemade-circuits.com/2013/08/simple-zero-drop-solar-charger-circuit.html

Reply
Swagatam says:
March 10, 2014 at 8:17 am

You are welcome!

The IC 324 has four quad opamps in one package, the supply for the entire IC is at the pins 4 and 11.

Reply
surya kiran says:
January 27, 2014 at 11:23 am

hi i am planning to connect this mppt circuit io dual axis solar tracker.
1) if my solar pannel rating is 50w what must be the R1,R2,R3 values
2) Are the relays in this circuit are 12v 8 pin relay
3)In the circuit an arrow pointing 10k resistor, is this resistor variable 10k resistor
4) in the circuit the connecting wires are disconnected in some places how the wires connected there

Reply
Swagatam says:
January 28, 2014 at 4:18 am

1) resistor values will depend on the battery AH rating.
2)relays are 12v 5 pin, spdt
3)those are presets or trimpots
4) the gap indicates that the overlapping wires are not connected in anyway.

Reply
Jonie Holtzhausen says:
January 10, 2014 at 5:34 am

Hi. Great site.
I agree with the mppt concept. We live completely of grid. We have 8 x 240w 24v solar panels connected with 4 x 40a 24v pwm controllers to batteries and a 3kw wind turbine. Power to the house is done via 3kw pure sine wave inverter. My idea is to connect a simple mppt circuit infront of my pwm controllers. Do you think this will enhance the solar panels charge rate, more important in early mornings and late afternoons.
If so can you please help with a simple design for 24v 40a mppt circuit than can installed in front of my pwm controllers.
Thanks
If so

Reply
Swagatam says:
January 16, 2014 at 4:38 am

Yes, you can try a buck converter using a IC555 circuit, connect it in between the pwm converter and the solar panel, one suitable design can be understood here:

https://www.homemade-circuits.com/2013/06/universal-ic-555-buck-boost-circuit.html

Reply
Jonie Holtzhausen says:
January 15, 2014 at 7:17 am

Hi
No sorry we have 24V battery bank. The PWM's are charging at 28.8V. My solar panels open V are +- 40V, I think it would be better to install a dc – dc converter in front of the PWM controller to change the higher volts low amp to lower volt higher amp. Can a converter be made with high current +-40A.
Thanks

Reply
Swagatam says:
January 11, 2014 at 5:27 am

Hi, Thanks!

It will depend on how the PWM controllers are configured.
I am assuming the connected batteries to be rated at 12V and the PWM controllers generating the required 14V for charging these batteries.
If this is so, then I think the PWM controllers would itself be quite efficient in optimizing the solar panel current, and external MPpTs wouldn't be required.

Reply
Swagatam says:
December 17, 2013 at 7:08 am

…if anybody points out faults in my designed circuits I would welcome that, but just criticizing blindly could be foolish..

Reply
Swagatam says:
December 17, 2013 at 7:03 am

I don't blame you for this comment because may be you yourself are much ill informed about electronics and might have failed to understand the above circuit details.

The above mppt cannot be considered a real mppt only because it doesn't employ I/V curve tracking but that doesn't take away its credit of being extremely efficient than the ordinary solar chargers that you are referring to.

How much do school students know about electronics and how much experience do they have this such field? I have seen experienced hobbyists consulting me for days and multiple failures until finally I make them succeed in making a particular project.

If your students couldn't make this simple looking solar optimizer then imagine what they would do with an actual mppt.

People appreciate me for providing alternate innovations, concepts, inventions that are easier and much effective.

It's unfortunate that there are folks who like to break their frustrations on creative helping engineers like me who are very rare online.

If you are unable to understand a concept you better quit instead of criticizing it due to your own inefficiency.

Reply
J.D. Bakker says:
December 16, 2013 at 10:43 pm

Then it may be fairest to be honest about that.

NONE of the circuits that you label as such, are actually MPPTs, as none of them will transfer maximum power to their load (the battery). If you want a cheap and easy way to non-MPPT charge a battery, you could suffice with a diode between solar panel and battery, perhaps with a relay or MOSFET to turn of charging once the battery is full. This will work better than any of the designs you've posted.

Misinformation is worse than no information at all. Two project teams at my school have attempted to use your designs as a basis for their MPPT, only to lose valuable time and resources before finding they don't work as advertised.They now risk failing their course, as we don't give them a passing grade if they can't demonstrate MPPT functionality. (They have learned a valuable lesson — don't just trust any information you find on the Internet…)

Reply
Ravi Judge says:
September 23, 2013 at 9:05 am

hi sir,how are you?actually i want to know i am already using a pwm based solar charger with my inverter.but want to use MPPT.can you publish a cicuit which can handle 24v 30 amp. thanks

Reply
Swagatam says:
October 2, 2013 at 4:31 am

Yes you can do it, the following two circuits can be combined to produce the intended effects:

https://www.homemade-circuits.com/2013/04/simple-solar-mppt-circuit-using-ic555.html

https://www.homemade-circuits.com/2013/06/universal-ic-555-buck-boost-circuit.html

Reply
ravi judge says:
October 1, 2013 at 10:58 am

thanks sir,can i divide the circuit in 2 part in first part the battery will be directly connected to the solar and in the evening and before noon a voltage amplifier will increase the volt to a desired level.is it possible?

Reply
Swagatam says:
September 24, 2013 at 1:46 pm

Hi Ravi,

I'll try to design it for you, however making the SMPS part in the MPPT can be little difficult, if I succeed I'll post it here for you.

Reply
Back to Newest

Need Help? Please Leave a Comment! We value your input—Kindly keep it relevant to the above topic! Cancel reply

Your email address will not be published. Required fields are marked *

Primary Sidebar

circuit simulator image

Subscribe to get New Circuits in your Email

Categories

  • Arduino Projects (95)
  • Audio and Amplifier Projects (133)
  • Automation Projects (18)
  • Automobile Electronics (103)
  • Battery Charger Circuits (87)
  • Datasheets and Components (109)
  • Electronics Theory (149)
  • Energy from Magnets (27)
  • Games and Sports Projects (11)
  • Grid and 3-Phase (20)
  • Health related Projects (27)
  • Home Electrical Circuits (13)
  • Indicator Circuits (16)
  • Inverter Circuits (95)
  • Lamps and Lights (159)
  • Meters and Testers (71)
  • Mini Projects (28)
  • Motor Controller (68)
  • Oscillator Circuits (28)
  • Pets and Pests (15)
  • Power Supply Circuits (91)
  • Remote Control Circuits (50)
  • Renewable Energy (12)
  • Security and Alarm (64)
  • Sensors and Detectors (106)
  • SMPS and Converters (34)
  • Solar Controller Circuits (60)
  • Temperature Controllers (43)
  • Timer and Delay Relay (49)
  • Voltage Control and Protection (42)
  • Water Controller (37)
  • Wireless Circuits (31)

Other Links

  • Privacy Policy
  • Cookie Policy
  • Disclaimer
  • Copyright
  • Videos
  • Sitemap

People also Search

555 Circuits | 741 Circuits | LM324 Circuits | LM338 Circuits | 4017 Circuits | Ultrasonic Projects | SMPS Projects | Christmas Projects | MOSFETs | Radio Circuits | Laser Circuits | PIR Projects |

Social Profiles

  • Twitter
  • YouTube
  • Instagram
  • Pinterest
  • My Facebook-Page
  • Stack Exchange
  • Linkedin

Recent Comments

  • Swagatam on Boost Converter Calculator (Non-Isolated)
  • Swagatam on How to Make Dog Barking Preventer Circuit using High Frequency Deterrence
  • NgPark on Boost Converter Calculator (Non-Isolated)
  • Yogesh on How to Make Dog Barking Preventer Circuit using High Frequency Deterrence
  • Swagatam on About Me

© 2026 · Swagatam Innovations