• Skip to main content
  • Skip to primary sidebar

Homemade Circuit Projects

Need circuit help? Post them in the comments! I've answered over 50,000!

Blog | Categories | About | Hire Me | Contact | Calculators-online
You are here: Home / Motor Controller / Single Phase Variable Frequency Drive VFD Circuit

Single Phase Variable Frequency Drive VFD Circuit

Last Updated on June 30, 2026 by Swagatam 324 Comments

In this post I have explained a single phase variable frequency drive circuit or a VFD circuit for controlling AC motor sped without affecting their operational specifications.

Table of Contents
  • What is a VFD
  • How it Works
  • How to Calculate Single Phase VFD Parameters
    • Input Power Calculations:
    • Output Power Calculations:
    • Formula:
    • What is its Importance
      • Remember:
    • VFD Sizing:
    • Motor Speed Control:

What is a VFD

Motors and other similar inductive loads specifically do not "like" operating with frequencies that might be not within their manufacturing specs, and tend to become a lot inefficient if forced to under such abnormal conditions.

For example a motor specified for operating with 60Hz may not be recommended to work with frequencies of 50 Hz or other ranges.

Doing so can produce undesirable results such as heating up of the motor, lower or higher than the required speeds and abnormally high consumption making things very inefficient and lower life degradation of the connected device.

However operating motors under different input frequency conditions often becomes a compulsion and under such situations a VFD or a variable frequency Drive circuit can become very handy.

A VFD is a device which allows the user to control the speed of an AC motor by adjusting the frequency and voltage of the input supply as per the motor specifications.

This also means that a VFD allows us to operate any AC motor through any available grid AC supply regardless of its voltage and frequency specs, by suitably customizing the VFD frequency and voltage as per the motor specifications.

This is normally done using the given control in the form of a variable knob scaled with different frequency calibration.

Making a VFD at home may sound to be a difficult proposition, however a look at  the design suggested below shows that after all it's not so difficult to build this very useful device (designed by me).

How it Works

If you do not wish to read the whole explanation, then you can watch this video instead:

OK, so I have designed this simple, basic VFD controller circuit which can be used to control all types of 220V or 120V single phase AC motor, as per the desired specifications. Let's try to understand how the circuit is designed to work.

simple VFD circuit diagram

Referring to the above circuit diagram the proposed VFD circuit works in this way: The IC IRS2453 is configured as the basic full bridge or H-bridge inverter circuit which generates square wave output whose frequency is determined by the values of the Rt and Ct components of the circuit.

The output of this inverter is used to control the desired motor, whose speed need to be controlled as per the VFD rules.

In order to convert this square wave inverter into a sine wave VFD circuit, I have configured an adjustable SPWM generator stage using the IC 555 astable and an op-amp comparator.

The IC 555 is wired as a PWM astable circuit to generate the fast triangle waves as the carrier frequency which is fed to the non-inverting input of the comparator op-amp IC 741.

The slow triangle wave, which acts as the reference signal, is extracted from the Rt, Ct junction of the IRS2453 IC and is fed to the inverting pin #2 of the comparator IC 741.

The reference signal is intentionally derived from the Rt, Ct pin of the inverter IC to ensure that the SPWMs are perfectly synchronized with the set frequency of the inverter.

This frequency caan be set by adjusting the Rt resistor which can be a potentiometer.

The 741 IC compares the two input waveforms and generates an equuivaalent SPWM output waveform from its pin#6.

This output is integrated with the low side MOSFET gates of the H-bridge inverter IC so that the square wave operation of the inverter is transformed into an SPWM equivalent sine wave output.

Now, how does this basic sine wave inverter circuit turns into a variable frequency drive?

It is done by providing the adjustments for the frequency control and the RMS voltage control of the inverter output which controls the motor.

So with this sine wave inverter you can adjust the output RMS frequency by adjusting the duty cycle of the SPWM carrier wave and the frequency can be adjusted by adjusting the Rt resistor of the inverter IC which supplies the reference frequency for the SPWM.

How to Calculate Single Phase VFD Parameters

Input Power Calculations:

Power Factor (PF):
This is all about measuring how efficiently we are using AC power. It is extremely important for making sure we size the Variable Frequency Drive (VFD) correctly.

Apparent Power (S):
This represents the total power that’s supplied to the VFD, and it includes both real power and reactive power.
Formula: S = V * I

Real Power (P):
This is the actual power that the motor uses to do its work.
Formula: P = V * I * PF

Reactive Power (Q):
This is the power that bounces back and forth between the source and the load without doing any useful work.
Formula: Q = √(S² - P²)

Output Power Calculations:

Motor Power (Pmotor):
This refers to the mechanical power that comes out of the motor.
Formula: Pmotor = (Torque * Speed) / 9550 (for horsepower).

The constant 9550 is an important number we use in the formula that connects power, torque, and rotational speed when we’re working with the SI system of units.

Formula:

Power (kW) = Torque (Nm) * Speed (rpm) / 9550

What is its Importance

So, what is so important with the constant 9550? It comes from how we convert between different units of power (in kilowatts), torque (in Newton-meters), and rotational speed (in revolutions per minute). This number helps us to tackle the differences in these units, making sure that our equation works correctly.

  • Power is measured in watts (W) or kilowatts (kW).
  • Torque is measured in Newton-meters (Nm).
  • Rotational speed is measured in revolutions per minute (rpm).

To get to that constant 9550, we need to think about a few things:

  • Converting power from kW to W.
  • Changing rotational speed from rpm to radians per second.
  • Using the relationship that says power equals torque times angular velocity (power = torque * angular velocity).

When we do these conversions and simplify everything, we end up with that handy constant 9550 in our formula.

Remember:

This formula is specifically designed for the SI unit system. If you happen to be using different units, for example like horsepower or foot-pounds, then you will need to use a different conversion factor to make it work.

Motor Efficiency (η):
This is a measure of how well the motor converts input power into output power.
Formula: η = Pmotor / Pinput

VFD Sizing:

VFD Power Rating:
The power rating of the VFD needs to be higher than the apparent power of the motor's, so that it can handle any potential overloads without an issue.

Input Current:
We can calculate the input current based on the VFD's power rating and the input voltage specifications.

Output Current:
We also need to figure out the output current based on the power rating of the motor and output voltage.

Motor Speed Control:

Motor Speed (N):
The speed of an induction motor is directly connected to the frequency of the voltage we apply.
Formula: N = (120 * f) / P (where f is frequency and P is the number of poles)

You'll also like:

  • motor speed with constant torqueConstant Torque Motor Speed Controller Circuit
  • temperaturecontrolledfandimmercircuitClimate Dependent Automatic Fan Speed Controller Circuit
  • simpletriacdiaccontrolcircuitUsing Triacs for Controlling Inductive Loads
  • BLDCBLDC Ceiling Fan Circuit for Power Saving

Filed Under: Motor Controller Tagged With: Drive, Frequency, Phase, Single, Variable, VFD

About Swagatam

I am an electronics engineer and doing practical hands-on work from more than 15 years now. Building real circuits, testing them and also making PCB layouts by myself. I really love doing all these things like inventing something new, designing electronics and also helping other people like hobby guys who want to make their own cool circuits at home.

And that is the main reason why I started this website homemade-circuits.com, to share different types of circuit ideas..

If you are having any kind of doubt or question related to circuits then just write down your question in the comment box below, I am like always checking, so I guarantee I will reply you for sure!



Previous Post: « How to Protect MOSFETs – Basics Explained
Next Post: I/V Tracker Circuit for Solar MPPT Applications »

Reader Interactions

Questions & Answers

Total Posts: 324
Newest Oldest
Pablo Guillermo Frank
May 25, 2026 • 3 months ago #207446

Hi,

Can you let me know where is the 220 / 120 V source?

What’s Motor supply +DC?

Where do the +12V come from?

Thanks in advance.

Reply
SwagatamAdmin
May 25, 2026 • 3 months ago #207454

Hey, all these voltages are required for supplying the respective stages. 12V can be from an DC adaptor, 120V, 220V or motor supply can be from the AC mains or an inverter…

Reply
Pablo Guillermo Frank
May 26, 2026 • 3 months ago #207509

Thanks, very much, for your response.

But, where are the 120 / 220 V connected to the circuit? I can see where the motor is connected, but not the AC Mains.

And I don’t understand what “Motor Supply +DC” means.

Thanks in advance.

Reply
SwagatamAdmin
May 26, 2026 • 3 months ago #207534

Thanks, I understand your problem…That source can be from a solar panel, rectified alternator DC or rectified DC 310V from mains supply…
“Motor Supply +DC” means the operating supply for the motor…

Reply
Vantechlabs
August 7, 2026 • 2 weeks ago #211479

If you only have 120 or 220V coming from the public grid (AC), you need to rectify the 110V to 220V if it’s the same AC motor of that voltage. its ok?

Reply
Adam Chinna
April 25, 2026 • 4 months ago #205749

Sir, I am very happy and thankful for your kind explanations given on the column. It helped me a lot to know the subject Electronics in a deeper way
Sir, I am very thankful to you if you pls kindly help me to build a SINGLE PHASE SOLAR VFD with an
Input Voltage: DC input range typically between 125V to 400V DC.
Output: Single-phase 200-240V AC, 50Hz. to operate a 0.5 hp monoblock water pump with
0.5 HP (0.37 kW) single-phase and with ampage of 3.8 A.
As it is safe to use a slightly higher 0.75 kW drive).
To run the pump on solar panels
Sir, requests you to pls kindly send circuit diagram and step by step explanation.
Thank you Sir.

Reply
SwagatamAdmin
April 25, 2026 • 4 months ago #205813

Thank you so much Adam, for your kind words and I am glad my explanations helped you to learn more.
I will definitely create an article on your mentioned subject and also post a video soon, and let you know once it is done…

Reply
TLM
January 26, 2026 • 7 months ago #199687

I realize this post and thread has been going for a while but I am looking into how to incorporate something like a VFD to control a resistive load and not for more than how it has soft-start using a ramp generator. I suppose what I am really looking for is a circuit that employs soft-start with variable timing to reach full on state.
The other approach I was thinking of is to have it current managed foldback operation where you could set the current limit and it would start soft and once it hits the limit, it would hold there till the resistive load reaches the crossing point and drops below the set threshold.
An example, for those wondering, would be the way a light bulbs resistance goes up as the filament warms up and thereby the load current drops.
The first thing I thought of was a VFD with soft-start.

Reply
SwagatamAdmin
January 27, 2026 • 7 months ago #199732

VFD and PWM both can be an overkill for such a simple application. I think a simple current controlled regulator should do the job for you, as explained in the following article. Please check the transistorized or the MOSFFET version of the circuits. If you want any further modifications, please let me know…:
https://www.homemade-circuits.com/universal-high-watt-led-current-limiter/

Reply
RAMA RANA Singh
September 15, 2025 • 11 months ago #185599

I want more items to share

Reply
Masood Salahuddin
April 29, 2025 • 1 year ago #174976

Can I use 220 volt single phase vfd to convert my normal one ton ac compressor to multi speed compressor and control with temperature sensor . If so please help me to design economical circuit for same 220 volt ac compressor.

Reply
SwagatamAdmin
April 29, 2025 • 1 year ago #175005

Mostly yes, single phase VFD can be used with AC compressor, but only if the motor of the compressor is not a capacitor-start type. However, using temperature sensors you can directly control the AC compressor output without a VFD.

Reply
FRANK MACRI
April 4, 2025 • 1 year ago #171578

Hi,
I have a bench drill Cthat will not go slower than 450 rpm approximately. I want to drill large diameter stainless steel holes and at that speed the bits burn out. Other than getting special expensive bits I think it may be a reasonable option to use less than 50 Hz input for the 700 watt single phase motor. I am thinking something around 5 to 10 Hz range. Can you advise and are there plans that you can supply for the project.

Cheers.

Reply
SwagatamAdmin
April 4, 2025 • 1 year ago #171583

Hi, I won’t recommend reducing the frequency, instead you can use a back emf based dimmer circuit as explained in the following post:
https://www.homemade-circuits.com/how-to-make-versatile-closed-loop/

Reply
Mohammad
March 11, 2025 • 1 year ago #169270

Hi
220V AC of main voltage increasing to 310V DC after rectifying by Diode & capacitor
i have question , with 310V how to control 220v motor ?

Reply
SwagatamAdmin
March 11, 2025 • 1 year ago #169283

Hi, the SPWM chopping from the 741 output across low side MOSFET gates will reduce the voltage to 220V or lower.

Reply
Everisto chilombo
July 15, 2024 • 2 years ago #154822

Hello Sir, how do I control the full H-bridge( with 2110) using Arduino in terms of code and connection?

Reply
SwagatamAdmin
July 15, 2024 • 2 years ago #154826

Hello Everisto, you can use the following Arduino code and integrate it with your 2110 IC for implementing an H-bridge inverter:
https://www.homemade-circuits.com/simple-arduino-sine-wave-inverter/

Reply
Ky D
February 22, 2024 • 2 years ago #149363

I wish you did a demonstration of a single-phase project in Multisim using P type and N type Mosfets

Reply
Dilip kalola
December 29, 2023 • 3 years ago #148268

Want complete guidence 3 phase vfd circuit diagram pcb ? Parts from where to buy

Reply
SwagatamAdmin
December 29, 2023 • 3 years ago #148273

3 phase VFD circuit is recommended only for the experts, it may not be suitable for newcomers.

Reply
Nitrous
March 19, 2023 • 3 years ago #141159

how are VFD’s applied to BLDC motors and what are the limits of “overspeed” based on frequency limits?
Thanks
Doug

Reply
Andrew Pratt
December 17, 2022 • 4 years ago #137564

Hi, Can this very useful circuit be used to drive a syncronous 220-240VAC motor?

Reply
SwagatamAdmin
December 17, 2022 • 4 years ago #137566

I think it can be used to drive the specified motor.

Reply
Derek Hyland
November 19, 2022 • 4 years ago #135297

Hi, I have couple of questions…
I would like to control a 1/2 HP single phase pump. The pump uses a permanent capacitor. Could I use a two phase VFD drive eliminating the need for the capacitor?
I would need to know the phase shift that the capacitor introduces.
I would also like to use a solar panel to drive the pump, varying the speed (freq.) and hence power according radiation…. the panel outputs 9.85 Amps @ 45.2 Volts (@ max radiation). I guess I would need a step up transformer to bring the voltage up to 220 V.

Reply
SwagatamAdmin
November 19, 2022 • 4 years ago #135321

Hi, Sorry, I am not an expert with motors, so I am not sure whether a capacitor start motor can be controlled with a 2 phase VFD or not, or whether the capacitor can be removed or not.
If you want to use a solar panel, then certainly you will need to use an inverter to convert the solar panel DC into a 220 AC for the motor

Reply
Benjamin
November 2, 2022 • 4 years ago #134283

hello, the circuits are tested? I did a simulation of the last schematic and it doesn’t work, included with the optocouplers to drive the mosfets

Reply
SwagatamAdmin
November 2, 2022 • 4 years ago #134287

Hello, you must do the simulation in a step wise manner, first try simulating the 555 section, then the 4017 section.
The 555 and the 4017 sections are perfectly tested OK, but the mosfet section has problems, which might need some corrections. I have added the necessary warning message with the diagram.

Reply
santosh babu
September 19, 2022 • 4 years ago #133369

can updated circuit with irs2453 be directly used for 250-300 v. or it need to modify as stated in comments using 4N25 optocoupler

Reply
SwagatamAdmin
September 19, 2022 • 4 years ago #133374

If you are using IRS2453 IC with 4 N channel mosfets then you can easily use 300 v directly with the mosfets, no optocouplers will be required.

Reply
Lcu
August 27, 2022 • 4 years ago #132714

Hi Swagatam,
thank you very much for this interesting article!
I’d like to build a VFD for a 240V universal motor of about 1 kW; it might peak at 40A during startup and at low speeds/high loads and I was not able to find suitable mosfets, since I’m also concerned that back emf can reach more than 600V.
Do you have any suggestion for suitable mosfets P/N (or mosfets configuration), and do you believe I should use some snubber network or the like?
I’d like very much to hear any suggestion from you, thanks!

Reply
SwagatamAdmin
August 28, 2022 • 4 years ago #132720

Thank you LCU,
For the P channel you can try FQP4P40 mosfets and IRF740 for the N channel. However, there seems to be a mistake in the last diagram.
The source voltage for the P channel mosfets is 310V, and the gate voltage is 12V which cannot work. For switching OFF the P channel effectively, its gate voltage must be same as its source voltage.
Therefore we may have to modify the H bridge section in the last diagram through opto couplers for effective switching of the P channel mosfet as shown in the following example design:

4047 solar transformerless inverter compressed

Reply
Tmac
December 26, 2022 • 4 years ago #137966

FQP4P40 has a max Vgs of 30V or -30V. When the optocoupler shorts the gate to ground you will have around 0V at the gate and 310V at the source. Would this not make Vgs -310V and destroy the mosfet?

Reply
SwagatamAdmin
December 26, 2022 • 4 years ago #137974

You are right! I think this can be rectified by adding a 15V zener diode across the gate/source pins of the P channel mosfets.

Reply
DRU
May 27, 2022 • 4 years ago #122019

whats the function of bc 557 in the last circuit ? can it or anything else be removed to simplify even more it ?

Reply
SwagatamAdmin
May 27, 2022 • 4 years ago #122021

BC557 allows the IC2 555 to work with a constant current which ensures the PWMs are always consistent regardless of Dc supply variations

Reply
Anilkumar V
May 16, 2022 • 4 years ago #121104

Dear Sir,
I wish to make your last drawing…..using 8 mosfet…it is simple from other…So pl give mosfets number…8 nos..

Reply
SwagatamAdmin
May 16, 2022 • 4 years ago #121168

Hello Anilkumar, the upper mosfets can be any 400 V P-channel mosfets, and the low side mosfets can be any 400 V mosfets.

Reply
Anilkumar V
May 9, 2022 • 4 years ago #120456

Sir,
I wants single phase 230v 50 hz 2800rpm circuit…is it possible for 2800rpm pump…

Reply
SwagatamAdmin
May 10, 2022 • 4 years ago #120478

Yes that’s possible by adjusting the output frequency to 50 Hz.

Reply
Anilkumar V
May 7, 2022 • 4 years ago #120269

Sir,
I will try this method Surely…..

Reply
SwagatamAdmin
May 7, 2022 • 4 years ago #120286

Sure Anil, you can try it.

Reply
dru
March 31, 2022 • 4 years ago #117548

in the last circuit you changed again to the 4017 ic or is it worng ?

Reply
SwagatamAdmin
March 31, 2022 • 4 years ago #117557

Nothing wrong, it is correct.

Reply
dru
March 31, 2022 • 4 years ago #117558

is it 10-500hz in 50hz line right ? in 60hz will be 12-600hz ? can’t it go lower like 3-6hz ? what modification it would need for that ?

Reply
SwagatamAdmin
March 31, 2022 • 4 years ago #117563

Frequency can be adjusted by adjusting the R1 pot in the last circuit. It can be any value between 10 and 500 Hz.

Reply
dru
May 27, 2022 • 4 years ago #122020

can i reduce this pot to have less range like using 50k or 10k pot wil give what range ?
what pot can give 0-100hz ?

Reply
SwagatamAdmin
May 27, 2022 • 4 years ago #122022

You can try a 100k pot

Reply
dru
March 31, 2022 • 4 years ago #117565

and can it be lower than 10 ?

Reply
SwagatamAdmin
March 31, 2022 • 4 years ago #117567

yes it can be lower than 10 Hz

Reply
j k barik
January 25, 2022 • 5 years ago #110457

Hello swagatam
my fridge is 200watts . But because of high surge / starting current the inverter trips. What is the best solution to run the fridge? super capacitor , car battery , change to invreter compressor etc?

Reply
SwagatamAdmin
January 25, 2022 • 5 years ago #110476

Hello JK, The only feasible way is to either to adjust the trip setting to higher level, r to replace the inverter with a higher power inverter. If existing inverter power can be upgraded by adding more number of external batteries then that is also a good option. Super capacitors might not be capable of handling this issue unless many of them are used.

Reply
shapur
September 24, 2021 • 5 years ago #98356

hi sir, i have a problem similar to this project would you help me to answer my question? i want to make a vfd by using igbt instead of mosfet. in all full bridge circuits with mosfets we have both n & p channel mosfets but on internet there are only n-channel igbt s. for making a full bridge with igbt should i use only four n-channel igbt ? ( do igbts have p-channel or they are only in n-channel?).many thanks

Reply
SwagatamAdmin
September 24, 2021 • 5 years ago #98392

Shapur, it depends on the driver IC. If the driver IC is built for driving only n channel deice then p channel cannot be used, and vice versa.

Reply
Bursać Milan
August 15, 2021 • 5 years ago #94512

Hello Swagatam,

is this circuit able to run a single phase induction motor capacitor start-capacitor run type?
If not, is there a possibility to make this kind of speed control for this motor type?
Regards.

Reply
SwagatamAdmin
August 15, 2021 • 5 years ago #94538

Hello Bursac, yes according to me the output can be used for operating a capacitor-start type motor, provided the output AC is filtered with some large non-polar capacitors.

Reply
Lachitha
June 19, 2021 • 5 years ago #91230

I”m a student of University college
I have a project in a single phase variable frequency driver
what is the most accurate circuit diagram here .

Reply
SwagatamAdmin
June 19, 2021 • 5 years ago #91239

The last circuit is the easiest one, but it will need to be built and verified stage-wise and is recommended only for experts who are well versed with electronic circuits, and exactly know how to proceed with the steps, with the help of an oscilloscope.

Also, please note that the various stages involved in the diagram are tested individually for other applications, but the whole unit as one has not been tested yet by me.

Reply
Haraj Tagore
April 13, 2021 • 5 years ago #88434

Your circuit are very interesting.
I would like to vary the speed of 1.5 HP induction motor.
Is it possible to have a complete circuit diagram including all the components value.

Reply
SwagatamAdmin
April 14, 2021 • 5 years ago #88443

Thank you, I have updated the parts in the last diagram clearly. All the resistors are 1/4 watt, and all the non-polar capacitors are ceramic type.
MOSFETs will be as per the input voltage rating

Reply
Manoj Rabari
February 22, 2021 • 5 years ago #87264

Hello Sir,

Is this possible to start single phase induction motor without start capacitor using above circuit?

Regards
Manoj

Reply
SwagatamAdmin
February 22, 2021 • 5 years ago #87275

Hello Manoj, I don’t think that’s possible with any circuit

Reply
sathish bekal
January 20, 2021 • 6 years ago #86244

i need full circuit diagram of Single Phase Variable Frequency Drive VFD Circuit

thanks

Reply
Girish Alekar
November 27, 2020 • 6 years ago #84859

I am Dip. Elec. Engr.
I want to run variable frequency device for my sewing machine.
I want to use IGBT
which circuit I should use?

Reply
SwagatamAdmin
November 28, 2020 • 6 years ago #84869

You can use the last circuit!

Reply
Chethan L
October 5, 2020 • 6 years ago #83004

Hii sir..
Can I use this circuit for 1.5hp single phase motor…which is required to run in 10rpm..
For long duration..
And plz explain me how inverter circuit is formed in the above circuit
Thanks sir…im waiting for Ur reply

Reply
SwagatamAdmin
October 5, 2020 • 6 years ago #83012

Hi Chetan, yes you can try it, but make sure you do it only once you have perfectly understood the working of all the stages of the circuit.

Please read the circuit operation for all the details.

Reply
MIRCEA KIRITESCU, Mr
January 30, 2020 • 7 years ago #75656

Dear Sirs,
I have to control a pump driven by an induction asincron motor, single phase 220V AC, 200w. The motor is sealed and the only „connection” to it is the 3-wire cable: line, null and earth.
The VFD has to run between 20 Hz (say LF) and 50Hz (say HF). The time to increase from LF to HF is variable depending the application (up to minutes). Also the value of LF may be variable. The VFD control (time to increase the frequency)will be made by an Arduino Nano.
Another aspect is the size of VFD. The room is restricted and may depend on application, basically, the body has to be slim and long. So I have to design my own PCB to cope with the room available in each project.
Which might be the circumstances to have a wiring diagram for a VFD 220V single phase input-output, 200w (1/4 HP)?
Thank you.

Reply
Jason Litvak
November 14, 2019 • 7 years ago #72054

Hello sir,
I have a my sweety vfd running my CNC Router spindle and it ran fine for months then all of the sudden errored out with a drive circuit error. I can get it to power up and run but the spindle longer turns on. Any ideas?

Reply
SwagatamAdmin
November 14, 2019 • 7 years ago #72062

Hello Jason, most probably it could be due to damaged MOSFETs which are directly responsible for controlling the motor…

Reply
DragonDen7
October 28, 2019 • 7 years ago #71485

Hellow
I am curious and it did not say in the article that I saw. Is it 110 in and what out? Or is it 220 in? If it is 220 can it be altered? I hope so I live in a trailer park and 220 is forbidden by management. But I have a big 110 breaker just setting their unused waiting for me to run it to the shed/machine shop So I can fire up my old professional machines with the help of your VFD I hope. I have had a great deal of practice making my own circuit boards this one seems a lot bigger then what I am used to but I will not be a problem. I have a nice little CNC board etcher that I made sitting in my bedroom.

Reply
SwagatamAdmin
October 28, 2019 • 7 years ago #71488

Hi, the concept can be used with 220V and 110V as well. However the design is indeed complex, especially for anybody who hasn’t built a full bridge inverter yet. I would rather recommend building the second circuit from the following link, and test it on a motor. If you succeed then you can alter the input side and replace it with the VFD control from the above article:

https://www.homemade-circuits.com/5kva-transformerless-inverter-circuit/

Reply
shiva patil
October 17, 2019 • 7 years ago #71133

hello sir , i want make single phase vfd for a fan(i e. 230 v 5 A, 60-90 W) . I want generate PWM signals by ARDINO. So can you suggest me the simulation ckt & the hardware circuit . Please send me the information regarding that.

Reply
SwagatamAdmin
October 17, 2019 • 7 years ago #71140

Hi Shiva, you can try this:

https://www.homemade-circuits.com/arduino-pwm-signal-generator/

Reply
Muhammad Arslan Hashmi
August 21, 2019 • 7 years ago #69494

Hello Sir .
How are you ?
Your VFD circuit is correct ?
It is because sometimes on internet some person adds incorrect circuits . Kindly give me a true Answer … I am very thanksfull to you .

Reply
SwagatamAdmin
August 21, 2019 • 7 years ago #69505

Thank you Muhammad,

the concept is correct, but please build it only if you have understood everything correctly and have the required level of expertise, otherwise you may not succeed with this complex project.

Reply
Raki
July 20, 2019 • 7 years ago #68581

Hi Swagatam ,

can you give me a simulation for the scheme,
I’ve tried proteus, but I can’t find ir2110 on my proteus. please help me sir

I have a project to control a single phase motor (VFD)

Please help … [email protected]

Thanks & regard

Reply
SwagatamAdmin
July 20, 2019 • 7 years ago #68590

Sorry Raki, I can’t because normally I don’t depend on software simulation results, instead I believe in mind simulation and practical testing.

Reply
Raki
July 22, 2019 • 7 years ago #68638

Thanks ..
I want to use your scheme for controlling a single phase motor.
1500 watt single phase motor

I have to use half bridge or full bridge ?

thanks & regard

Reply
Raki
September 10, 2019 • 7 years ago #70082

hello Mr. Swag,
I assembled a half-wave inverter. I experienced failure. i want to ask, what is the output voltage on pin 2 and 7 ic 4017? , what is the output voltage on the pin HO, LO,VB and VS ic ir2100. at no load condition .. thanks Mr.Swag

Reply
SwagatamAdmin
September 11, 2019 • 7 years ago #70094

Hello Raki, you must build and verify the different stages separately, and then integrate them together. The voltages will not reveal anything because the outputs are sequencing at a high frequency. You will need a frequency meter and an oscilloscope to test the various points, and before that you will have to understand how all the stages and the ICs are designed to work, their specifications etc.
This project is not for the newcomers.

Reply
raki
October 16, 2019 • 7 years ago #71110

Hello Sir …
in my halfbridge circuit

lf pin3 ic2 is not connected to the gate, the voltage at the source is measured 180V, and the lamp is on

but if pin3 ic2 is connected to the gate, the voltage at the source is measured 4V, and the lamp is off.

if all components are installed according to your design and soldered correctly. what else should i do?
please give me your advice

thank & regard

Reply
SwagatamAdmin
October 16, 2019 • 7 years ago #71113

Hello Raki, If you assemble everything together then it may show many problems. So you will have to build and confirm the various stages separately, and then join them step by step.

First build the IC1 and IC 2 stages and check the pin 3 of IC2 for a varying PWM in response to a varying external voltage at pin 5 of IC2.

After this build IC 4017 stage and connect IC1 output with it and confirm the output of IC 4017.
After this build the half bridge, and connect it with IC 4017 and check how a load responds to this.
If everything work perfectly then finally connect the pin3 of IC2 wit the MOSFeTs.

Reply
Raki
October 5, 2019 • 7 years ago #70754

hello sir,

in a half-wave circuit

Is the negative voltage on the motor connected only to the motor?
or also connected to ground (pin # source on LO mosfet)

best regards

Reply
SwagatamAdmin
October 5, 2019 • 7 years ago #70774

Hello Raki,

All the ground symbols are common and should be connected with the each other.

Reply
Raki
September 25, 2019 • 7 years ago #70498

hello sir .

may i know your email

thanks & regard

Reply
SwagatamAdmin
September 25, 2019 • 7 years ago #70502

Hello Raki,

please see the “contact” link at the top of the page.

Reply
SwagatamAdmin
July 22, 2019 • 7 years ago #68649

You will need a full bridge circuit, a half bridge is mistakenly shown…..it is not recommended for any motor.

Reply
Raki
July 22, 2019 • 7 years ago #68654

saya membaca artikel anda tentang ” Arduino SPWM Generator Circuit – Code Details and Diagram ” (// By Swagatam (my first Arduino Code)

bisakah code itu dimodifikasi ? saya membutuhkan pengendalian frekuensi untuk mengatur kecepatan motor satu fasa. saya menggunakan IC ir2110 sebagai driver

Thanks & regard

Reply
SwagatamAdmin
July 22, 2019 • 7 years ago #68660

Yes it can be modified but it cannot be varied using a pot.

The total time of the two sets of codes is 20 ms, so each set is 10 ms long…you can adjust the microsecond values to increase or decrease the 10 ms value to any other desired value proportionately.

Reply
Paul B.
July 9, 2019 • 7 years ago #68284

Swag,
I would like to use your design for a lathe in my wood shop. My question is will this work for my application?
The motor is 3/4 hp, 115V, 1PH, 60 Hz, 1720 RPM (no load), 6.7 FLA.
Please let me know. Thank you.

Reply
SwagatamAdmin
July 9, 2019 • 7 years ago #68295

Hi Paul, it will surely work for the specified motor. I would recommend the last circuit since it’s a full bridge circuit and will provide full control of the motor speed.

Reply
Paul B
July 11, 2019 • 7 years ago #68357

Thank you very much! I am anxious to give this a try and I’m sure I will be asking a few more questions before I am all done.

Reply
SwagatamAdmin
July 12, 2019 • 7 years ago #68365

Thank you, wish you all the best!

Reply
View Older Comments

Need Help? Please Leave a Comment! We value your input—Kindly keep it relevant to the above topic! Cancel reply

Your email address will not be published. Required fields are marked *

Primary Sidebar



Categories

  • Arduino Projects (95)
  • Audio and Amplifier Projects (134)
  • Automation Projects (18)
  • Automobile Electronics (104)
  • Battery Charger Circuits (90)
  • Datasheets and Components (109)
  • Electronics Theory (150)
  • Energy from Magnets and Earth (41)
  • Games and Sports Projects (11)
  • Grid and 3-Phase (20)
  • Health related Projects (27)
  • Home Electrical Circuits (13)
  • Indicator Circuits (16)
  • Inverter Circuits (100)
  • Lamps and Lights (163)
  • Meters and Testers (72)
  • Mini Projects (28)
  • Motor Controller (68)
  • Oscillator Circuits (30)
  • Pets and Pests (15)
  • Power Supply Circuits (91)
  • Remote Control Circuits (50)
  • Security and Alarm (65)
  • Sensors and Detectors (107)
  • SMPS and Converters (46)
  • Solar Controller Circuits (62)
  • Temperature Controllers (44)
  • Timer and Delay Relay (50)
  • Voltage Control and Protection (44)
  • Water Controller (37)
  • Wireless Circuits (31)



Circuit Simulator

circuit simulator image



Subscribe to get New Circuits in your Email



Other Links

  • Privacy Policy
  • Cookie Policy
  • Disclaimer
  • Copyright
  • Videos
  • Sitemap

People also Search

555 Circuits | 741 Circuits | LM324 Circuits | LM338 Circuits | 4017 Circuits | Ultrasonic Projects | SMPS Projects | Christmas Projects | MOSFETs | Radio Circuits | Laser Circuits | PIR Projects |



Recent Comments

  • Swagatam on Electronic Circuit Projects, Tutorials, and Practical Engineering Solutions
  • Swagatam on Electronic Circuit Projects, Tutorials, and Practical Engineering Solutions
  • Swagatam on 4 Simple Battery Desulfator Circuits Explored
  • Swagatam on 4 Simple Battery Desulfator Circuits Explored
  • Swagatam on PIR Controlled Solar Garden Light Circuit

Social Profiles

  • Twitter
  • YouTube
  • Instagram
  • Pinterest
  • My Facebook-Page
  • Stack Exchange
  • Linkedin

© 2026 · Swagatam Innovations