An MPPT as we all know refers to maximum power point tracking which is typically associated with solar panels for optimizing their outputs with maximum efficiency. In this post I have explained the 3 best  MPPT controller circuits for efficiently harnessing solar power and charging a battery in the most efficient manner.

Where an MPPT is Used

The optimized output from MPPT circuits is primarily used for charging batteries with maximum efficiency from the available sunshine.

New hobbyists normally find the concept to difficult and get confused with the many parameters associated with MPPT, such as the maximum power point, "knee" of the I/V graph etc.

Actually there's nothing so complex about this concept, because a solar panel is nothing but just a form of power supply.

Optimizing this power supply becomes necessary because typically solar panels lack current, but posses excess voltage, this abnormal specs of a solar panel tends to get incompatible with standard loads such as 6V, 12V batteries which carry higher AH rating and lower voltage rating compared to the panel specs, and furthermore the ever-varying sunshine makes the device extremely inconsistent with its V and I parameters.

And that's why we require an intermediate device such as an MPPT which can "understand" these variations and churn out the most desirable output from a connected solar panel.

You might have already studied this simple IC 555 based MPPT circuit which is exclusively researched and designed by me and provides an excellent example of a working MPPT circuit.

Why MPPT

The basic idea behind all MPPTs is to drop or trim down the excess voltage from the panel according to the load specs making sure that the deducted amount of voltage is converted into an equivalent amount of current, thus balancing the I x V magnitude across the input and the output always up to the mark...we cannot expect anything more than this from this useful gadget, do we?

The above automatic tracking and appropriately converting the parameters efficiently is implemented using a PWM tracker stage and a buck converter stage, or sometimes a buck-boost converter stage, although a solitary buck converter gives better results and is simpler to implement.

Design#1: MPPT using PIC16F88 with 3-Level Charging

In this post we study an MPPT circuit which is quite similar to the IC 555 design, the only difference being the use of a microcontroller PIC16F88 and an enhanced 3-level charging circuit.

MPPT using PIC16F88 with 3-Level Charging

Step wise Working Details

The basic function of the various stages can be understood with the help of the following description:

1) The panel output is tracked by extracting a couple of information from it through the associated potential divider networks.

2) One opamp from IC2 is configured as a voltage follower and it tracks the instantaneous voltage output from the panel through a potential divider at its pin3, and feeds the info to the relevant sensing pin of the PIC.

3) The second opamp from IC2 becomes responsible for tracking and monitoring the varying current from the panel and feeds the same to another sensing input of the PIC.

4) These two inputs are processed internally by the MCU for developing a correspondingly tailored PWM for the buck converter stage associated with its pin#9.

5) The PWM out from the PIC is buffered by Q2, Q3 for triggering the switching P-mosfet safely. The associated diode protects the mosfet gate from overvolatges.

6) The mosfet switches in accordance with the switching PWMs and modulates the buck converter stage formed by the inductor L1 and D2.

7) The above procedures produce the most appropriate output from the buck converter which is lower in voltage as per the battery, but rich in current.

8) The output from the buck is constantly tweaked and appropriately adjusted by the IC with reference to the sent info from the two opamps associated with the solar panel.

9) In addition to the above MPPT regulation, the PIC is also programmed to monitor the battery charging through 3 discrete levels, which are normally specified as the bulk mode, absorption mode, an the float mode.

10) The MCU "keeps an eye" on the rising battery voltage and adjusts the buck current accordingly maintaining the correct Ampere levels during the 3 levels of charging procedure. This is done in conjunction with the MPPT control, that's like handling two situations at a time for delivering the most favorable results for the battery.

11) The PIC itself is supplied with a precision regulated voltage at its Vdd pinout through the IC TL499, any other suitable voltage regulator could be replaced here for rendering the same.

12) A thermistor can be also seen in the design this may be optional but can be effectively configured for monitoring the battery temperature and feeding the info to the PIC, which effortlessly processes this third information for tailoring the buck output making sure that the battery temperature never rises above unsafe levels.

13) The LED indicators associated with the PIC indicate the various charging states for the battery which allows the user to get an up-to-date information regarding the charging condition of the battery throughout the day.

14) The proposed MPPT Circuit using PIC16F88 with 3-Level Charging supports 12V battery charging as well as 24V battery charging without any change in the circuit, except the values shown in parenthesis and VR3 setting which needs to be adjusted to allow the output to be 14.4V at the onset for a 12V battery and 29V for a 24V battery.

Programming code can be Downloaded here

Design#2: Synchronous Switch-Mode MPPT Battery Controller

The second design is based on the device bq24650 which  includes an advanced built-in MPPT Synchronous Switch-Mode Battery Charge Controller. It offers a high level of input voltage regulation, which prevents the charging current to the battery each time input voltage drops below a specified amount. Learn More:

Whenever the input is attached with a a solar panel, the supply stabilization loop pulls down the charging amp to ensure that the solar panel is enabled to produce maximum power output.

How the IC BQ24650 Functions

The bq24650 promises to provide a constant-frequency synchronous PWIVI controller with optimal level of accuracy with current and voltage stabilization, charge preconditioning, charge cut-off, and charging level checking.

The chip charges the battery in 3 discrete levels: pre-conditioning, constant current, and constant voltage.

Charging is is cut-off as soon as the amp level nears the 1/10 of the rapid charging rate. The pre-charge timer is set to be at 30 minutes.

The bq2465O without a manual intervention restarts the charging procedure in case the battery voltage reverts below an internally set limit or reaches a minimum quiescent amp sleep mode while the input voltage goes below the battery voltage.

The device is designed to charge a battery from 2.1V to 26V with VFB internally fixed to a 2.1V feedback point. The charging amp spec is preset internally by fixing a well matched sensing resistor.

The bq24650 can be procured with a 16 pin, 3.5 x 3.5 mm^2 thin QFN option.

Circuit Diagram

mppt 2

Datasheet bq24650

BATTERY VOLTAGE REGULATION

The bq24650 employs an extremely accurate voltage regulator for the deciding on the charging voltage. The charging voltage is preset by means of a a resistor divider from the battery to ground, with the midpoint hooked up the VFB pin.

The voltage at the VFB pin is clamped to 2.1 V reference. This reference value is used in the following formula for determining the desired level of regulated voltage:

V(batt) = 2.1V x [1 + R2/R1]

where R2 is linked from VFB to the battery and R1 is connected from VFB to GND. Li-Ion, LiFePO4, as well as SMF lead acid batteries are ideally supported battery chemistries.

A majority of over the shelf Li-ion cells can now be effectively charged up to 4.2V/cell. A LiFePO4 battery supports the process of a substantially higher charge and discharge cycles, but the down side is that the the energy density is not too good. The recognized cell voltage is 3.6V.

The charge profile of the two cells Li-Ion and LiFePO4 is preconditioning, constant current, and constant voltage. For an effective charge/discharge life, the end-of-charge voltage limit may possibly be cut down to 4.1V/cell however it‘s energy density could become a lot lower compared to the Li-based chemical specification, lead acid continues to be much preferred battery because of its reduced production expenses as well as rapid discharge cycles.

The common voltage threshold is from 2.3V to 2.45V. After the battery is seen to be completely topped up, a float or trickle charge becomes mandatory in order make up for the self-discharge. The trickle charge threshold is 100mV-200mV below the constant voltage point.

INPUT VOLTAGE REGULATION

A solar panel may have an exclusive level on the V-I or V-P curve, popularly known as the Maximum Power Point (MPP), wherein the complete photovoltaic (PV) system relies with optimum efficiency and generates the required maximum output power.

The constant voltage algorithm is the most easy Maximum Power Point Tracking (MPPT) option available. The bq2465O automatically shuts down the charging amp such that the maximum power point is is enabled for producing maximum efficiency.

Switch ON Condition

The chip bq2465O incorporates a "SLEEP" comparator to identify the means of supply voltage on the VCC pin, because of the fact that VCC may be terminated both from a battery or an external AC/DC adapter unit.

If the VCC voltage is more significant the SRN voltage, and the additional criteria are fulfilled for the charging procedures, the bq2465O subsequently begins making an attempt to charge a connected battery (please see the Enabling and Disabling Charging section).

lf SRN voltage is higher with respect to the VCC, symbolizing that a battery is the source from where the power is being acquired, the bq2465O is enabled for a lower quiescent current ( <15uA) SLEEP mode to prevent amperage leakage from the battery.

lf VCC is below the UVLO limit, the IC is cut-off, after which VREF LDO is switched off.

ENABLE AND DISABLE CHARGING

The following concerned aspects need to be ensured before the charging process of the proposed MPPT Synchronous Switch-Mode Battery Charge Controller Circuit is initialized:

• Charging process is enabled (MPPSET > 175mV)

• The unit is not in Under-Voltage-Lock-Out (UVLO) functionality and VCC is above the VCCLOWV limit

• The IC is not in SLEEP functionality (i.e. VCC > SRN)

• VCC voltage is below the AC over-voltage limit (VCC < VACOV)

• 30ms time lapse is fulfilled after the first power-up

• REGN LDO and VREF LDO voltages are fixed at the specified junctures

• Thermal Shut (TSHUT) is not initialized - TS bad is not identified Any one of the following technical issues may inhibit the proceeding charging of the battery:

• Charging is is deactivated (MPPSET < 75mV)

• Adapter input is disconnected, provoking the IC to get into a VCCLOWV or SLEEP functionality

• Adapter input voltage is below the 100mV above battery mark

• Adapter is rated at higher voltage

• REGN or VREF LDO voltage is not as per the specs

• TSHUT IC warmth limit is identified • TS voltage happens to move out of the specified range which may indicate that the battery temperature is extremely hot or alternatively much cooler

Self-Triggered In-built SOFT-START CHARGER CURRENT

The charger by irself soft-starts the charger power regulation current each time the charger moves into the fast-charge to establish that there is absolutely no overshoot or stressful conditions on the externally connected capacitors or the power converter.

The soft-start is featured with of stepping-up the chaging stabilization amp into eight uniformly executed operational steps next to the prefixed charging current level. All the assigned steps carry on for around 1.6ms, for a specified Up period of 13ms. Not a single external parts are called for enabling the discussed operational function.

CONVERTER OPERATION

The synchronous buck PWM converter employs a predetermined frequency voltage mode with feed-forvvard control strategy.

A version III compensation configuration let's the system to incorporate ceramic capacitors at the output stage of the converter. The compensation input stage is associated internally between the feedback output (FBO) along with an error amplifier input (EAI).

The feedback compensation stage is rigged between the error amplifier input (EAI) and error amplifier output (EAO). The LC output filter stage needs to be determined to enable a resonant frequency of around 12 kHz - 17 kHz for the device, for which the resonant frequency, fo, is formulated as:

fo = 1 / 2 π √LoCo

An integrated saw-tooth ramp is allowed to compare the internal EAO error control input to alter the duty-cycle of the converter.

The ramp amplitude is 7% of the input adapter voltage enabling it to be permanently and completely proportional to the input supply of the adapter voltage.

This cancels away any sort of loop gain alterations on account of a variation in the input voltage and simplifies the loop compensation procedures. The ramp is balanced out by 300mV so that a zero percent duty-cycIe is achieved when the EAO signal is below the ramp.

The EAO signal is likewise qualified to outnumber the saw-tooth ramp signal with a purpose to achieve a 100% duty cycIe PWM demand.

Built in gate drive logic makes it possible accomplishing 99.98% duty-cycle at the same time confirming the N-channel upper device consistently carries as much as necessary voltage to always be 100 % on.

In the event the BTST pin to PH pin voltage reduces below 4.2V for longer than three intervals, in that case the high-side n-channeI power MOSFET is switched off while the low-side n-channe| power MOSFET is triggered to draw the PH node down and charge-up the BTST capacitor.

After that the high-side driver normalizes to 100% duty-cycle procedure until the (BTST-PH) voltage is observed to decline low yet again, on account of outflow current depleting the BTST capacitor below 4.2 V, as well as reset pulse is reissued.

The predetermined frequency oscillator maintains rigid command over the switching frequency under most circumstances of input voltage, battery voltage, charge current, and temperature, simplifying output filter layout and retaining it away from the audible disturbances state.

Design#3: Fast MPPT Charger Circuit

The third best MPPT design in our list explains a simple MPPT charger circuit using the IC bq2031 from TEXAS INSTRUMENTS, which is best suited for charging high Ah lead acid batteries quickly and with a relatively fast rate

Abstract

This practical application article is for the individuals who may be developing an MPPT-based lead acid battery charger with the aid of bq2031 battery charger.

This article includes a structural format for charging a 12-A-hr lead acid battery employing MPPT (maximum power point tracking) for improving charging efficiency for photovoltaic applications.

Introduction

The easiest procedure for charging a battery from a solar panel systems could be to hook up the battery straight to the solar panel, however this may not the most effective technique.

Presume a solar panel bears a rating of 75 W and generates a current of 4.65 A with a voltage of 16 V at normal test environment of 25 ° C temperature and 1000 W/m2 of insolation.

The lead acid battery is rated with a voltage of 12 V; directly hooking up the solar panel to this battery would decrease the panel voltage to 12 V and only 55.8 W (12 V and 4.65 A) could be produced from the panel for charging.

A DC/DC converter may be most suitably needed for economical charging here.

This practical application document explains a model, making use of the bq2031 for effective charging.

I-V Characteristics of Solar Panel

mpptcircuit 3

Figure 1 displays the standard aspects of a solar panel systems. Isc is a short-circuit current that streams through the panel in case the solar panel is short circuited.

It happens to be the optimum current that may be extracted from the solar panel.

Voc is the open-circuit voltage at the terminals of the solar panel.

Vmp and Imp are the voltage and current levels where maximum power can be purchased from the solar panel.

While the sunshine decreases the optimum current (Isc) which may be attained, the highest current from the solar panel also suppresses. Figure 2 indicates variation of I-V characteristics with sun light.

The blue curve links the details of the maximum power at various values of insolation

mpptcircuit 1 1

The reason for the MPPT circuit is to try to sustain the working level of the solar panel at the maximum power point in several sunshine conditions.

As observed from Figure 2, the voltage where maximum power is delivered does not alter greatly with sunshine.

The circuit constructed with the bq2031 makes use of this character to put into practice MPPT.

An additional current control loop is included with decrease the charge current as the daylight decreases as well as to sustain solar panel voltage around the maximum power point voltage.

slva378a 3

bq2031-Based MPPT Charger

Datasheet BQ2031

Figure 3 displays the schematic of a DV2031S2 board with an added current control loop added to carry out the MPPT making use of the operational amplifier TLC27L2.

The bq2031 keeps the charging current by retaining a voltage of 250 mV at sense resistance R 20. A reference voltage of 1.565 V is created by using 5 V from U2.

The input voltage is compared with the reference voltage to produce an error voltage that could be implemented at the SNS pin of bq2031 to decrease the charge current.

The voltage (V mp) where maximum power can be acquired from the solar panel is conditioned employing resistors R26 and R27. V mp = 1.565(R 26 +R 27)/R 27.

With R 27 = 1 k Ω and R 26 = 9.2 k Ω, V mp = 16 V is achieved. TLC27L2 is internally adjusted with a bandwidth of 6 kHz at V dd = 5 V. Mainly because the bandwidth of TLC27L2 is significantly below the switching frequency of bq2031, the added current control loop continues to be constant.

The bq2031 in the earlier circuit (Figure 3) offers an optimum current of 1 A.

In case the solar power panel can furnish adequate power to charge the battery at 1 A, the outer control loop does not proceed into action.

However if the insulation reduces and the solar power panel struggles to deliver sufficient energy to charge the battery at 1 A, the outer control loop decreases the charge current to preserve input voltage at V mp.

The outcomes demonstrated in Table 1 confirm the functioning of the circuit. The voltage readings in bold type signify the issue whenever the secondary control loop is minimizing the charge current to preserve input at V mp

References:

Texas Instruments

MPPT Synchronous Switch-Mode Battery Charge Controller Circuit

You'll also like:

  • 1.  Simple Solar Tracker System – Mechanism and Working
  • 2.  How to Calculate Solar Panel, Inverter, Battery Parameters
  • 3.  Bike Magneto Generator 220V Converter
  • 4.  Solar Water Heater Circuit with Battery Charger
  • 5.  Programmable Solar Porch Light Circuit
  • 6.  Connecting MPPT with Solar Inverter

About Swagatam

I am an electronics engineer with over 15 years of hands-on experience. I am passionate about inventing, designing electronic circuits and PCBs, and helping hobbyists bring their projects to life. That is why I founded homemade-circuits.com, a website where I share innovative circuit ideas and tutorials. Have a circuit related question? Leave a comment.... I guarantee a reply!

Previous Post: « 3 Easy Capacitive Proximity Sensor Circuits Explored
Next Post: How to Design High-Pass and Low-Pass Filter Circuits Quickly »

Reader Interactions

Comments

  1. Dan says

    May 10, 2025 at 5:04 pm

    A colleague said he can use lm324 comparator in line with a sg3525 Ic as the pwm signal generator to make a standard mppt controller?

    please kindly explain how this can be possible, does it mean he would have 4 fixed standard duty cycle points which the comparator will be changing from one point to another or what, sir?

    Reply
    • Swagatam says

      May 10, 2025 at 5:28 pm

      Dan, It is difficult to describe the circuit unless I see the schematic diagram…

      Reply
      • Dan says

        May 12, 2025 at 1:42 am

        I don’t have it, he just discussed it, that he used sg3525 and lm324, and it was efficient 95%

        Reply
  2. Dan says

    May 3, 2025 at 7:46 pm

    is possible for a mppt circuit to have high frequency transformer- chopper and inductor in it.

    Reply
    • Swagatam says

      May 4, 2025 at 9:36 am

      Yes, it is possible and all commercial MPPTs use high frequency ferrite inductor.

      Reply
      • Dan says

        May 5, 2025 at 3:22 am

        Thanks sir.

        please what is the meaning and the essence of the pwm tracking, because I understood that the voltage and current vary in the sun intensity. please how does these variations affect the charging efficiency?

        from My observation of the commercial mppt, I don’t notice its difference from buck converter.

        please how can I extrapolate the first circuit lm358 into a sg3524 buck converter.

        Reply
        • Swagatam says

          May 5, 2025 at 8:44 am

          Dan, you are correct, MPPT is basically an optimized buck or boost converter, and there’s nothing called PWM tracking in it. Yes, but PWM adjustment is used for adjusting the duty cycle to ensure that the voltage to battery is correctly optimized so that the solar panel is able to provide maximum efficiency using its maximum power point, a voltage level at which the solar panel works most efficiently. So basically we are trying to extract maximum power from the solar panel without causing its voltage to drop due to excessive loading, by optimizing the duty cycle of the buck or the boost converter.
          The first circuit is unnecessarily complex, I will try to design an easier concept without a microcontroller soon…

          Reply
          • Dan says

            May 7, 2025 at 6:42 pm

            I appreciate your enlightenment, please which one has better efficiency between 555 buck converter and sg3524?

            I don’t need adjustable duty cycle, I just need a fixed duty cycle buck converter that can optimise the current at a fixed current.

            I need a circuit that can buck convert 150v to 24v at high efficiency.

            I am really grateful for your support, thanks.

            Reply
            • Swagatam says

              May 8, 2025 at 7:32 am

              Dan, Using IC 555 is more compact and efficient compared to using SG3525 IC.
              You can take the help of the following articles and build a customized buck converter very easily:
              https://www.homemade-circuits.com/calculating-inductor-value-in-smps/
              https://www.homemade-circuits.com/buck-converter-calculator/

              Reply
            • Dan says

              May 10, 2025 at 3:41 am

              Sir, between buying a smps adapter for 150v AC to 24vdc and getting a mppt controller which is better? I think mppt has an efficiency of about 96%.

              Reply
              • Swagatam says

                May 10, 2025 at 8:43 am

                Dan, I think buying the SMPS is better because it will also give you almost the same results in terms of efficiency….assuming the SMPS is of a high quality.
                https://www.homemade-circuits.com/convert-smps-into-solar-charger-circuit/

                Reply
                • Dan says

                  May 12, 2025 at 2:18 am

                  please how will know high quality smps to 24vdc

                  Reply
          • Dan says

            May 7, 2025 at 7:19 pm

            Also sir, which is more efficient between buck converter and smps?

            Buck converter averagely lacks high frequency ferrite transformer but all have normal inductor.

            please kindly educate Me for clarity.

            I have Ac input voltage that I want to rectify and buck convert to small voltage.

            please kindly guide, sir.

            Reply
            • Swagatam says

              May 8, 2025 at 8:01 am

              Dan, buck converter is also an SMPS without isolation. Buck converters are more efficient if the application is a DC to DC but not good if you want safety and isolation and if you want to use AC mains as the input supply…

              Reply
      • Dan says

        May 7, 2025 at 7:21 pm

        Sir, with this high frequency ferrite inductor, All mppts use smps topology rather than common buck converter, please am I correct?

        Reply
        • Swagatam says

          May 8, 2025 at 8:10 am

          Dan, SMPS stands for switch-mode-power-supply, which means using high frequency switching of a ferrite inductor for the conversions… so all buck converters use SMPS topology. A flyback transformer is used only if isolation is required from the input supply.

          Reply
      • Dan says

        May 10, 2025 at 4:25 pm

        I want to confirm that all mppt controllers have flyback transformer for isolation and inductor core for filtering noise and harmonics, please I am correct?

        Reply
        • Swagatam says

          May 10, 2025 at 5:09 pm

          It is not compulsory, you can build DC MPPT using a single inductor also….

          Reply
    • Dan says

      May 10, 2025 at 4:29 pm

      I want to confirm that all mppt controllers have flyback transformer for isolation and inductor core for filtering noise and harmonics, am I correct, sir?

      Reply
      • Swagatam says

        May 10, 2025 at 5:10 pm

        It depends on you, how you want to design it…but it is not compulsory for a DC to DC MPPT.

        Reply
  3. sewando says

    December 6, 2024 at 4:19 pm

    how would i design and construct an mppt charger by switching method

    Reply
    • Swagatam says

      December 6, 2024 at 5:33 pm

      The above circuits also use switching principle…

      Reply
  4. App says

    October 28, 2024 at 9:59 pm

    Hello,

    I have a school assignment to design and build an optimizer for a solar panel. It should be controlled by a microcontroller and designed for up to 40V and 15A.

    Do you think the first design is suitable? Could you possibly help me with it?

    Thank you, App

    Reply
    • Swagatam says

      October 29, 2024 at 2:25 pm

      Hi, The fist design is suitable for your application, but I am not sure about the code, because it looks so lengthy and I have not yet tested it…
      You can build a highly optimized solar panel controller simply by using an appropriately rated buck converter.

      Reply
      • App says

        October 31, 2024 at 7:52 pm

        Have you ever tried building one yourself? Could you possibly share the design you used for your optimizer? I also found other articles published by you, so if there’s another design you believe is best, I’d love to hear about it.

        Thanks, App

        Reply
        • Swagatam says

          October 31, 2024 at 7:59 pm

          Sorry, currently I dot not have a microcontroller based design, if it is without a microcontroller then I can suggest…

          Reply
          • App says

            November 2, 2024 at 3:30 pm

            It would be great to have a recommendation that doesn’t involve a microcontroller, at least as a starting point. Plus, I could learn something from an experienced person.

            Reply
            • Swagatam says

              November 2, 2024 at 5:41 pm

              Sure! You can try the second circuit diagram from the following article, using an iron core transformer. In that case the frequency for the lower TIP122 transistor will be 50 Hz:
              https://www.homemade-circuits.com/homemade-solar-mppt-circuit-maximum/

              Reply
  5. Klin Ton says

    November 30, 2023 at 3:06 pm

    good morning sir…????????????????
    can this charger, charge 12v 100 mps or more than

    Reply
    • Swagatam says

      November 30, 2023 at 4:29 pm

      Hi Klin, sorry it won’t charge a 100 amp battery

      Reply
  6. Chiebo says

    June 12, 2023 at 4:44 am

    Well done job Engr. Swagatam.
    Plz, if you can help me with the list of components and their specifications, I will be glad… thanks sir in anticipation..

    Reply
  7. Stephen says

    June 11, 2023 at 10:24 am

    I need help designing a single cell lithium battery charging circuit. It should have the following features

    • It should take power input from USB VBus AND/OR a 6v solar panel
    • It should have Powerpath
    • Safety: overcharging, overdischarging, short circuit and reverse polarity protection

    I was looking up various ICs all day, but couldn’t narrow it down. If you could point me a schematic that is already tested that would be a great help.

    Reply
    • Swagatam says

      June 11, 2023 at 10:40 am

      Please specify the mAh rating and the voltage rating of your cell.

      Reply
  8. Ike says

    March 15, 2023 at 6:30 pm

    hi Swagatam, this mppt charge control is rated to handle 120w/12 or 220w/24 panel only how I modify it to handle 1500-2500watt panel with 80v

    Reply
    • Swagatam says

      March 15, 2023 at 7:32 pm

      Hi Ike, Sorry, I do not have a 1500-2500watt rated MPPTs at the moment.

      Reply
      • Ike says

        March 15, 2023 at 10:50 pm

        Please can you help me with it within a short time.????

        Reply
  9. Nirban says

    March 13, 2023 at 5:30 pm

    Can you please give me 12 v 10 amp mmpt diagram with program for solar street light controller

    Reply
    • Swagatam says

      March 13, 2023 at 6:02 pm

      Sorry, I do not have this circuit with me at this moment

      Reply
  10. Shams says

    February 16, 2023 at 12:22 am

    Plz give me a diagram of 12v 60amp mppt charger

    Reply
  11. B Tschacher says

    December 2, 2022 at 3:17 am

    I’ve been looking closely at the PIC based controller and think a good addition to this design would be to include a Poly fuse to the Vreg output along with a 5.6v Zener to grnd down line from the 100uf cap. This would be some added protection for the MCU which these are a bit pricey and with the code on it makes it a critical part. It will also protect the rest of the circuit from issues although those components are not so V critical. Including a digital V meter would be nice also to monitor B+ voltage. I’m starting construction on this and will be working to push power up to around 750 watts by adding main diodes and Mosfets, fuses, etc where needed.

    Reply
    • Swagatam says

      December 2, 2022 at 9:45 am

      I truly appreciate your interest in this project and wish you good luck.
      However, I am a bit skeptical about the program code, it looks huge and complex, so please test and verify it before buying all the components.

      Reply
  12. B Tschacher says

    December 1, 2022 at 12:24 am

    I have a question for your consideration on the PiC based controller here. That 68kufd cap is a game killer for this project ,Pretty high priced. What I’m wondering is if this much capacitance is truly required? The cost pretty much works out HIGH priced going with multiple lower values no matter what putting a parallel bank together. You have any input on this such as using a lot less like just 10k?

    Reply
    • Swagatam says

      December 1, 2022 at 9:31 am

      The 68000uF capacitor value is dependent on the battery Ah value. For bigger batteries this capacitor will need to be bigger and vice versa. However, you can experiment with smaller values also and see if that works or not.

      Reply
  13. B Tschacher says

    November 28, 2022 at 11:46 am

    Hello again. I’ve been observing a lot of the posts you’ve made now for several years. Now I’ve been looking at this post and specifically design #1. There are still some specifics I want to consider here to make this project suitable for considerably higher power levels, like around ~500 to 800 watts to supply power for an off grid RV system. To speed things up do you have any input I could make use of?

    Reply
    • Swagatam says

      November 28, 2022 at 1:21 pm

      Hi, thanks for exploring this website. The design #1 can be upgraded to the any desired power output by suitably upgrading the Q1, D1, D2 and the inductor wire thickness.
      However, I am somehow skeptical about the PIC program code, it looks huge and needs to be checked practically if it really works or not.

      Reply
      • B Tschacher says

        November 29, 2022 at 1:25 am

        Thanks for getting back. I’m currently studying some other posts you did, the de sulphator project. Your’s and another, the 4047 and an NE555 based unit. I’m going to have to put all of this on hold for a month or so till I can place an order for parts to work with these.

        Reply
        • Swagatam says

          November 29, 2022 at 9:46 am

          Sounds great! no problems, wish you all the best with the projects….let me know if you any further questions.

          Reply
  14. [email protected] says

    October 6, 2022 at 12:19 pm

    If a buck boost circuit required so that it can charge at low voltage time?

    Reply
  15. Moustafa Shehab says

    August 25, 2022 at 3:02 am

    I have 15 batteries 12V 150Ah connected serially to earn 180V 150Ah to run the UPS elevator.
    I need to recharge them from solar by MPPT. What is the best way to connect MPPT that can give me 180V DC to recharge 15 Batteries?

    Reply
    • Swagatam says

      August 25, 2022 at 9:12 am

      Building an MPPT for a 180V 150 Ah battery can be quite huge and complex, therefore i would recommend you to buy it ready-made instead of making one. The company engineer will explain you how to connect and use it.

      Reply
  16. OGBUNUKO says

    August 18, 2022 at 6:24 pm

    Can you send the full Skech of the circuit diagram
    And the list of the components

    Reply
  17. prasad rao bhupati says

    December 23, 2021 at 9:24 pm

    what is reference between pwm & MPPT

    Reply
  18. prasad rao bhupati says

    December 23, 2021 at 9:21 pm

    what is effencey between pmw & mppt

    Reply
  19. rdalek says

    December 19, 2021 at 10:24 am

    I’m interested in this article but at the end, it seems to just cut off mid sentence. Can you check and make sure it’s all posted? It seems it got cut off.

    Reply
    • Swagatam says

      December 19, 2021 at 11:28 am

      The last design is from texas instrument, for the details you can refer to the following datasheet..

      https://www.ti.com/lit/an/slva378a/slva378a.pdf

      Reply
      • rdalek says

        December 19, 2021 at 12:23 pm

        Thank you. I missed that. I enjoy your articles. The way you explain things makes more sense to me. Sometimes data sheets tend to complicate things.

        Thanks again.

        Reply
        • Swagatam says

          December 20, 2021 at 8:46 am

          It’s my pleasure and I am glad you liked the articles.

          Reply
  20. bazy says

    September 28, 2021 at 8:39 pm

    Tanks sir but where can i apply arduino nano in that circuit diagram

    Reply
  21. bazy says

    September 28, 2021 at 7:50 pm

    Sure by using arduino nano right?

    Reply
    • Swagatam says

      September 28, 2021 at 7:57 pm

      All Arduino will work actually….

      Reply
  22. Raju Karimgol says

    May 31, 2021 at 1:54 pm

    Dear Sir,
    I’m seeking for DIY MPPT charger kits.
    Can you provide me the contact.

    Reply
    • Swagatam says

      May 31, 2021 at 4:07 pm

      Sorry Raju, I do not have readymade kits for these projects!

      Reply
  23. Derrick says

    January 1, 2021 at 5:01 am

    Please kindly explain to me in the first MPPT were you use LM358 for voltage and current reading how the lm358 works here because i see you ground pin 5 and pin 6 connected to a siginal from the shunt then a capacitor and resistor from the output of this opamp then the also the output to pin 7 to the adc pin please explain to me here i want to understand the use of all this and also the voltage reading network why pass it thru a voltage follower and not direct from the divider to the adc? I really need to understand this coz I’ve seen it done like this many times in different circuits.

    Reply
    • Swagatam says

      January 1, 2021 at 8:29 am

      This design is not mine so I haven’t investigated it yet….The idea was taken from a reputed electronic magazine.

      Reply
  24. amar nath sharma says

    December 13, 2020 at 3:24 pm

    can i use 37 volt 16amp solar pannel for maxium curre4nt

    Reply
    • Swagatam says

      December 13, 2020 at 5:51 pm

      yes you can!

      Reply
  25. amar nath sharma says

    December 13, 2020 at 3:17 pm

    bro its too long code
    how many languages you used in this code
    i hope that this code is not comfortable for this microcontrollar

    Reply
    • Swagatam says

      December 13, 2020 at 5:55 pm

      Amar, it was published in an old electronic magazine. If you are not comfortable with it you can the other designs.

      Reply
  26. Adnan says

    December 5, 2020 at 1:07 am

    Sir!
    You’re doing good work.
    I am motivated very much from your articles and get a lot of knowledge about inverters and converter.
    Sir! can you suggest me a design of a solar charge controller and inverter design also for 30W PV.
    It will be very helpful for .
    I want to work on it for my final year project.
    Its will be great favor for me.
    Thank you.

    Reply
    • Swagatam says

      December 5, 2020 at 8:37 pm

      Adnan, you can try the concepts presented in the following article for making a solar inverter with your 30 watt panel:

      https://www.homemade-circuits.com/how-to-make-solar-inverter-circuit/

      Reply
  27. Steve says

    November 18, 2020 at 11:33 pm

    Swagatam,
    I have a question on Design #1 in your “3 Best MPPT Solar Charge Controller Circuit for Efficient Battery Charging”.
    Under nominal conditions (25 degc, 1000 W / sq m) my solar panel is spec’ed for a Vmp = 19.65v and an Imp = 4.33A.
    With a 12v battery, will your design develop ~19.65v on the solar panel itself ? And will the solar panel itself deliver ~4.33A ?
    Thanks Once More, Steve

    Reply
    • Swagatam says

      November 19, 2020 at 5:32 pm

      Steve, an MPPT is designed to manage and transfer power to the load with highest possible efficiency, it cannot modify or force the solar panel to generate a desired amount of power.

      If your panel is optimally generating the mentioned 19.65V at 4.33 amps, then the MPpT will try to ensure that this 19.65 x 4.33 = 85 watts of power is efficiently managed and utilized by the load with minimum wastage, however if your panel is claiming to generate the above power but actually it is generating only 70 watts, then MPPT cannot force the panel to generate the rated 85 watts.

      for a 12V battery the MPPT in the above designs will try to transfer the 85 watts at the maximum of 95% efficiency to a 12V battery…in other words it will convert the 19.65V into 14V, and enhance the current to 85 / 14 = 6 Amps

      Reply
  28. Iyke says

    September 14, 2020 at 4:03 pm

    Hi Swag,

    So much info you put out there. This is much appreciated.

    I have to question please..
    1. I want to know the current flow of a typical mppt controller.. Example, I am sure current flow from the solar side is one way into the mppt, the battery side is a two way in and out of the mppt. So what of the load side, is it a two way in and out or just a one way. Please I need to know so I can consider connecting my inverter to the load side for the batteries to charge from either the solar or the inverter (with an inbuilt charger).

    2. Am trying to work on a semi self charging system. I want you to please share your thoughts. Instead of using an array of solar panels, I want to introduce a mere battery charger to be connected to the mppt controller same way the solar would have been connected with all other items remaining same. This is just to eliminate the expenses on buying arrays of solar panel…

    Reply
    • Swagatam says

      September 14, 2020 at 6:16 pm

      Thanks Iyke, it will depend which load sinks more current and that load will attract more current. The battery is also a load along with the external load. Your panel current specs must be more than the combined current requirement of the battery and the external load. Also the two loads must be protected with individual current control units so that both the loads are able to share the current uniformly, else the heavier load will suck in all the current not allowing the the other load to get the required amount of current.

      Sorry I could not understand your second question? The MPPT itself is a battery charger, no need of adding any further circuitry to it.

      Reply
  29. thomas berton says

    September 4, 2020 at 6:52 pm

    I would like to discuss a solar battery system to power a light on a peice of equipment I manufacture. Would you be willing to work with me?

    Reply
    • Swagatam says

      September 4, 2020 at 7:46 pm

      Hello, Please specify your requirement, I’ll try to solve it for you! I can work with you if you have a beneficial offer for my business.

      Reply
      • thomas berton says

        September 4, 2020 at 7:54 pm

        Can we reply off line?

        Reply
        • Sanjay Deshpande says

          December 29, 2022 at 4:30 pm

          Can I use it for 350w 12v solar panels and get max chare out of it to charge my 2*100Ah batteries?

          Reply
          • Swagatam says

            December 29, 2022 at 5:37 pm

            Yes you can, with the help of a boost converter circuit.

            Reply
  30. Justin says

    August 19, 2020 at 5:04 pm

    Thank you sharing your wealth of knowledge on MPPT’s. After reading the above and the other MPPT posts you have shared, I can’t figure out if I what to use the battery at the same time I am charging it with a MPPT, if connecting the load directly to the battery will effect the MPPT’s ability to correctly charge the battery?

    Reply
    • Swagatam says

      August 19, 2020 at 8:24 pm

      If the combined power of the battery and the load exceeds the MPPT output specs then definitely it will affect the MPPT performance.

      Reply
  31. Kashif lakhani says

    August 3, 2020 at 6:04 pm

    Dear Sir, please guide for DC 160v to 240v Convert into 220v AC circuit.
    My into is from 16 batteries of 12v

    Reply
    • Swagatam says

      August 3, 2020 at 6:21 pm

      Kashif, you can use the first circuit from this article:

      https://www.homemade-circuits.com/5kva-transformerless-inverter-circuit/

      Reply
  32. Olly says

    May 14, 2020 at 8:28 pm

    Hi friend, like I promised to get back to you in case I have issues with the project. 1) What voltage I’m I supposed to get from pin#8 of IC1 i.e. TP4? I’m getting random voltage ranging from 5V to 1V.
    2) Why is the absorb LED not indicating at all? The thermistor and bulk LED keeps blinking alternately.
    3) I guess VR3 is used to set the float of the controller because when I vary it, at a point the float LED will blink while the bulk indicator goes off.
    4) What description would you give the indicator? I just swapped different toroid inductors and all are giving the same results. For the capacitor, I paralleled 4pieces of 4,700uF together.
    Those are my observations/questions please I’d like you to respond to them. Thanks always.

    Reply
    • Swagatam says

      May 15, 2020 at 8:32 am

      Hi friend, i wish I could help you, but since I have not tested it practically I can’t provide any useful help. The design was published in one of old magazines.
      The inductor is only for filtering the output DC

      Reply
  33. Bai Borko says

    April 21, 2020 at 4:00 pm

    Hello,

    I build the project from Design#1 with pic16f88 . Seem it works . Please explain/share how to set VR2 and VR3 ?
    With VR3 adjust 14.4 V on the battery . But with VR2 also can change this voltage .
    I want to understand how to do proper setting .
    I want also to understand what is the purpose of S1?

    Reply
  34. DHARNIDHAR KUMAR says

    March 18, 2020 at 12:15 pm

    Sir I have read all your article that you have given above the mppt Solar charge controller and I have seen all those diagram but I don’t not understand which diagram is necessary for 1000 watt solar panel.
    PLESE REAPLY ME SIR
    THANKS

    Reply
    • Swagatam says

      March 18, 2020 at 8:31 pm

      Dharnidhar, you can upgrade all of the shown designs by suitably modifying the MOSFETs for handling 1000 watt load and input supply

      Reply
  35. ch wazir says

    February 21, 2020 at 12:48 pm

    programming for pic16f88 in your design 1 is requested.

    Reply
    • Swagatam says

      February 21, 2020 at 1:03 pm

      please find the download link in the same section

      Reply
  36. ch wazir says

    February 20, 2020 at 2:13 pm

    sir yours design no.1 is very excellent. plz tell how to program the pic16f88. thanks so much.

    Reply
    • Swagatam says

      February 20, 2020 at 4:30 pm

      Ch, it is not my design it was taken from a magazine. The program code is given in the link at the end of the explanation.

      Reply
  37. manoj says

    February 14, 2020 at 5:26 pm

    not getting MPPT results, rather getting same current as pwm or direct connection to solar panel. Also mosfet 9560 getting too hot. pl explain , if some ware wrong, or possible mistake

    Reply
    • Swagatam says

      February 14, 2020 at 6:17 pm

      It is designed by Texas Instrument engineers so it has to work if everything is connected exactly as shown. However, this is recommended only for the experts…if you are finding it difficult you can try a simple buck converter instead:

      https://www.homemade-circuits.com/5v-pwm-solar-battery-charger-circuit/

      Reply
  38. Srinivas says

    February 2, 2020 at 12:49 pm

    I want to design MPPT charge controller for 50w,12v solar pannel…and also I want to make the output voltage from the charger controller should be varied based upon our requriment…can you please send me the circuit diagram… And the ratting of the components that I have to use sir….

    Reply
    • Swagatam says

      February 2, 2020 at 6:01 pm

      Srinivas, You can use the second circuit for your application. The output voltage can be set through the given formula, by adjusting the values of R1, R2
      All resistors are 1/4 watt, MOSFETs are IRF540

      Reply
  39. MUHAMMED ASLAM A S says

    November 15, 2019 at 4:46 pm

    What is the algorithm for the first mppt design 1.& Please explain the design

    Reply
  40. Sagar M. Busa says

    November 15, 2019 at 1:49 pm

    Sir,
    Where can I find PIC16F88 programming for above circuit.

    Reply
    • Swagatam says

      November 15, 2019 at 8:22 pm

      Just above design#2

      Reply
  41. ERNST MASSEANT says

    October 31, 2019 at 10:04 am

    How to design a charge controller for high voltage battery bank?

    Reply
    • Swagatam says

      October 31, 2019 at 10:34 am

      https://www.homemade-circuits.com/220v-lithium-ion-battery-bank-charger/

      Reply
  42. Muhammed says

    October 13, 2019 at 6:31 pm

    Can you send the code required for the microcontroller.

    Reply
  43. sfk says

    August 21, 2019 at 8:10 pm

    Thanks for works.

    Can please share about Design #1 PIC16F88 specifications. Example Max Amp. Max Panel Voltage Input, amp and outputs, idle power, effective…

    Thank you

    Reply
    • Swagatam says

      August 21, 2019 at 9:16 pm

      Hi sfk, the current will depend on the MOSFET Specs of Q1, voltage is specified on the solar panel.

      Reply
      • sfk says

        August 21, 2019 at 9:40 pm

        Hi Swagatam, Thanks for reply.
        I have 2×100 watt solar Panel (each one, 17,30Volt-6,05Amp) so i need 15Amp output. In diagram Q1 is IRF 9540 i think it’s enough for power.
        My other question; if i want to more amp for example 60amp output, its enoughf to change only change mosfest Q1 or need to connect several parallel from the same mosfet?

        Thank you

        Reply
        • Swagatam says

          August 22, 2019 at 9:26 am

          Hi sfk,

          IRF9540 will be enough for 15 amps, so need to change it.
          for 60 amp you can two more of these in parallel, on a common heatsink.
          You will also need to ensure that D1 is rated twice the amount of output current…and also the inductor wire muse be appropriately dimensioned

          Reply
          • sfk says

            August 24, 2019 at 2:37 am

            Thanks for reply,
            I will make this circuit and write the results here.
            I couldn’t read a few elements in the diagram.
            What are d1 and d2 diode values?

            You will say this is only for experts but i am not 🙁
            If you have a pcb diagram, could you please you share

            Thanks

            Reply
            • Swagatam says

              August 24, 2019 at 12:23 pm

              Yes this circuit is for advanced and experienced users only, absolutely not recommended to newcomers. If you are a newcomer, please do not try it. There’s a high possibility that you would not succeed to get the intended results.

              I do not have a PCB diagram, even with PCB it is not suitable for newcomers.

              Reply
  44. Chris Owen says

    June 9, 2019 at 8:19 pm

    I have 3 charge sources to charge 2 12VDC AGM 1000Ah batteries, and a continuous drain at this time unknown.
    to charge I use.
    A 12V Alternator 120 amp when the engine is running.
    A repurposed UPS 110Vac Transformer with a 14VDC output unknown current at this time. To charge at night from shore power. Need a circuit for this…

    What I am having issues finding is a controller for the following Photovoltaic cell. To charge a 12Vdc battery bank or maybe a 24V bank with some help modding.
    A 36V Solar cell.
    Max power Pmax 245W
    Max power voltage Mmp 30.7
    Max power current Imp 7.98A
    Open circuit voltage Voc 37.3v
    Open circuit current Isc 8.47A
    Max system Voltage DC600V
    Max series Fuse 15A
    Max Bypass Diode 15A
    Fire Rating Class C
    so this is the ratings on the cell.

    I want to charge a 12v bank while unplugged from the Solar so I need a circuit to provide the power to the inputs from the other sources. I seen a few circuits for the UPS that I am looking at building. The Alternator I guess I need to have a isolation on too.

    Do I need to prevent back flow from the other charge sources or is that built into the circuits???

    I have just not found any built items that meet the requirements of the solar system, and threw the UPS re-purpose, together to charge the batteries to 12v due to the constant draw from equipment that runs at night.
    I need to get the draw …

    Reply
    • Swagatam says

      June 10, 2019 at 11:05 am

      As far as I have understood, you have an alternator running on diesel, another alternator running on shore power, and a solar panel. You want to use all the resources to charge the mentioned battery appropriately depending on their availability, and the diesel alternator needs to be switched OFF while the remaining sources are available??

      Reply
      • Chris Owen says

        June 10, 2019 at 11:32 am

        Pretty close,
        When I am driving the Gas/Diesel is the primary 12v source.
        When I park (day time usually) the Solar is the secondary source when the engine is off and not connected to shore power 120Vac.
        When I get home at night I plug in to shore power which also is my data connection (another project).

        I need to keep 2 12vdc batteries (1000ah each) charged via each source.
        There are many 12v circuits that I think will work but the Solar is ~30vdc that needs to charge 12vdc (14vdc) that is where I am having the issue. As far as I know a 24V solar charge control wont work…???
        But you were pretty close.
        Thanks,

        Reply
        • Swagatam says

          June 10, 2019 at 12:51 pm

          No problem, for the solar charger you can implement the following design:

          https://www.homemade-circuits.com/5v-pwm-solar-battery-charger-circuit/

          You can adjust R8/R9 to get 14V at the output for the battery.

          Reply
          • Chris Owen says

            June 12, 2019 at 7:05 pm

            Thank you, I get so busy it takes a moment to respond.

            I will have a look at that project.

            Reply
            • Swagatam says

              June 12, 2019 at 7:35 pm

              No Problem!

              Reply
  45. Ubaid says

    June 8, 2019 at 11:52 pm

    Sir I am designing the charge controller for 300W PV source and 180ah battery will these circuits work ?
    plz guide me.

    Reply
    • Swagatam says

      June 9, 2019 at 9:17 am

      Hi Ubaid, yes these will work for a 180 Ah battery

      Reply
      • Sanjay says

        October 5, 2020 at 1:21 pm

        I want to use PIC circuit to charge 170Ah(80+90Ah) batteries.Is it possible?Or what changes are to be done in the circuit?

        Reply
  46. taurai mirimi says

    April 7, 2019 at 8:01 pm

    great, just great stuff. thanks

    Reply
    • Swagatam says

      April 7, 2019 at 8:37 pm

      Thank you!

      Reply
  47. green says

    March 30, 2019 at 3:15 pm

    sir,
    can you support Power electronics designing products

    Reply
    • Swagatam says

      March 30, 2019 at 4:30 pm

      Hi, Do you mean SMPS calculations, sorry I can’t.

      Reply
  48. Jignesh patel says

    May 17, 2018 at 9:11 pm

    Hi sir I am designing 14.8v 18200mAh lithium ion battery charger using 40w solar but I am.not able to make ciruit. By google I came on this post but I didn’t found any link for circuit and c code. Can you help.me in this ?

    Reply
    • Swagatam says

      May 18, 2018 at 11:33 am

      Hi Jignesh, This circuit was referred from one of the electronic magazines, and whatever it had I have uploaded it above, I do not have any alternative version or details for the design.

      Reply
  49. Pollob says

    April 17, 2018 at 4:50 pm

    I build this circuit.but didn’t work.only thermistor Led blinking.money waste

    Reply
    • Swagatam says

      April 18, 2018 at 7:28 am

      This circuit is strictly for the experts who know everything about microprocessors and electronics.

      Reply
  50. PolloB says

    December 21, 2017 at 7:23 pm

    plaease add battery Capacity meter via 6led

    Reply
  51. Emmanuel says

    July 6, 2017 at 1:09 am

    Hello
    Please…. I can't find the MPPT charge controller circuitry on this page. Can u please send it to my email: [email protected]

    Reply
  52. Cameron Martin says

    May 17, 2017 at 8:07 am

    Hi, Thank you for your reply. I had a look at the link you provided regarding hysteresis and noted the dual detection features of Op Amps. This has resolved another issue I have so thank you very much for your link.

    Reply
    • Swagatam says

      May 17, 2017 at 3:51 pm

      You are most welcome, and glad I could help!!

      Reply
  53. Cameron Martin says

    May 17, 2017 at 12:11 am

    Hi, I really like your circuit. I understand the LM358 voltage follower circuit for voltage measurement however I don't understand the use of the 2.2k resistor.

    I would also be most grateful if you could explain the purpose of the 1.5k, 8.2k, and 68k resistors on the LM358 for low side current sensing as I am trying to do the mathematics to work out the voltage drop in mV I should expect over the 0.01 ohm currents sensing resistor. I am basing my theoretical calculations using a 20 Amp supply from the panel and the 0.01 Ω resistor. My raw calculation is 200mV however I am guessing the resistor circuit adds some gain.

    V = I x R
    V = 20 Amps x 0.01 Ω
    V = 0.2 Volts
    V = 0.2 x 1000 = 200 mV

    Any help you can provide would be greatly appreciated.

    Reply
    • Swagatam says

      May 17, 2017 at 4:11 am

      Hi, thanks, however this is not my circuit, it was sent to me by one of the avid readers of my blog for publishing, and that's the reason I wouldn't be able to answer your questions precisely.

      the 2k2 resistors doesn't make sense for sure unless there;s something that may be linked inside the MCU with these resistors, so you may try removing it and see if it makes any difference.

      the resistors 1.5k, 8.2k, and 68k at the inverting input appears like some kind of hysteresis arrangement, but interpreting this network looks confusing since pin#3 is grounded

      you an see a similar explanation here:

      https://www.homemade-circuits.com/2017/01/universal-battery-charger-circuit.html

      Reply
  54. Dinca Silviu says

    April 7, 2017 at 6:48 am

    Hi. Could this circuit be used for charging a 10v 640ah battery pack from solar panel 30v 10 amp to obtain 30 amp carging current? Thanks.

    Reply
    • Swagatam says

      April 7, 2017 at 11:50 am

      Hi, your battery will require 10 x 64 = 640 watt or 64 ampere for charging whereas the panel is rated to produce only 30 x 10 = 300 watts….so it's not possible

      Reply
  55. network advise says

    March 26, 2017 at 9:54 am

    Thank you sir

    Reply
  56. network advise says

    March 25, 2017 at 2:56 pm

    Hi sir
    This Srinivas
    WHAT IS EQUALANT TL499À
    Thanks & regards

    Reply
    • Swagatam says

      March 25, 2017 at 3:21 pm

      Hi Srinivas, I could not figure out the reason of using TL499, when an ordinary 7812 could also work, you can try a 7812 and check the results…

      Reply
  57. Kyren Katwaroo says

    February 11, 2017 at 1:24 am

    I am a final year student at the University of the West Indies. For my final year project I am building this same exact circuit to charge a 12V lead acid battery using a 24V, 5A solar panel that i constructed for myself. Do I have to use a 12V 10A DC fuse?

    Reply
    • Swagatam says

      February 11, 2017 at 11:18 am

      you can connect it if you wish to, there's nothing critical about it. the circuit is current controlled anyway

      Reply
    • Kyren Katwaroo says

      February 16, 2017 at 12:55 am

      ok thanks. what voltage to set VR2 at? or how should i set VR2?

      Reply
    • Swagatam says

      February 16, 2017 at 12:25 pm

      sorry I have not yet studied that since this is not my design…and since it's a programmed one

      Reply
      • Olly says

        April 28, 2020 at 7:48 pm

        Thanks for the post. However, I have questions concerning the design
        1) if TL499A is replaced with 7812 as you said, is the voltage not too much for the pic16f88
        2) What is the purpose of TP1, TP2 and TP4 respectively
        3) I guess there’s error in the D1 connection. All legs are connected together
        4) What value would you suggest for D3 and D4.
        Thanks for your usual response.

        Reply
        • Swagatam says

          April 29, 2020 at 9:10 am

          1) Yes 7812 will be high for the IC, in that case you can use an LM317 based regulator.
          2) TP refers to test point
          3) I have corrected D1 connection.
          4) D3, D4 can be 1N4007 diodes

          Reply
          • Olly says

            April 29, 2020 at 9:26 am

            Thanks bro for the reply. I’ll keep in touch with you if there’s any other question.

            Reply
          • Olly says

            May 15, 2020 at 9:34 am

            OK thanks! That means inductor value is not critical.

            Reply
            • Swagatam says

              May 15, 2020 at 12:30 pm

              Yes it is not critical..

              Reply
  58. Ravipal Singh says

    January 23, 2017 at 11:50 am

    sir, can i use 2 or three irf 9540 in parallel to get higher current,and same in mbr 20100ct diode.please reply.thanks

    Reply
    • Swagatam says

      January 24, 2017 at 3:04 am

      Ravipal, yes that's possible for the mosfet, but if you want to use parallel diodes, then make sure to attach the sets over a common heatsink so that those diodes are able to share the heat and conduct uniformly

      Reply
  59. Ram Patil says

    January 4, 2017 at 7:56 am

    Dear Sir,
    Circuit consist of 68,000 micro F DC capacitor. It costs too much & require big space. Is there any alternative for this?

    Thanks,
    Ram

    Reply
    • Swagatam says

      January 4, 2017 at 3:32 pm

      Ram, higher capacitor value will allow proportionately higher current for the load and will prevent the output from dropping with higher loads….nevertheless you can dimension it as per your load wattage through some practical experimentation.

      Reply
  60. Ravipal Singh says

    January 3, 2017 at 11:26 am

    hi sir,whats about d1 and d 2 to charge higher voltage battries.Do i need to change them ,because they are in series of battry.Dr they are able to handle higher voltage and current.thanks

    Reply
    • Swagatam says

      January 3, 2017 at 2:29 pm

      Hi Ravipal, yes you are right, those diodes must be equally rated as Q1 in terms of handling the specified load voltage and current

      Reply
      • Srinivas says

        January 31, 2020 at 6:49 pm

        sir….i want mppt solar charge controller for 50w solar paannel…with variable output voltage….. Could you please provide me circuit diagram… And the ratting of the components sir…

        Reply
        • Swagatam says

          January 31, 2020 at 7:39 pm

          Srinivas, you can use the second concept from the above article.

          Reply
          • Olly says

            May 14, 2020 at 10:06 pm

            It will connect with pin#1….mistakenly not shown in the diagram….
            I copied the above statement from your reply and I couldn’t figure out what you meant. Please what is connecting pin#1?

            Reply
            • Swagatam says

              May 15, 2020 at 11:13 am

              Please ignore it, it was probably meant to indicate the connection of pin1 with pin2 of the IC2

              Reply
    • Ravipal Singh says

      January 4, 2017 at 6:24 am

      hi sir,Thanks for reply,Can you please specify the value of Q1 and D1 ,D2 to charge 96 volt 150 ah batteries.thanks

      Reply
    • Swagatam says

      January 4, 2017 at 4:01 pm

      ravipal, you may have to check online for this to find the favorable device…you can search for "120V 10amp mosfet datasheet" for the required results

      Reply
  61. Unknown says

    December 29, 2016 at 12:24 pm

    Hi sir,
    Can I use this circuit for my 1600 VA 24 volt solar inverter and 250 watt 24 volt solar PV panels? I am using two batteries in series of rating 12 volt 220 VA each.
    Thanks,
    Ram

    Reply
    • Swagatam says

      December 29, 2016 at 4:46 pm

      You can try it out, just make sure Q1 is appropriately upgraded to handle the high current….

      Reply
    • Ram Patil says

      December 30, 2016 at 6:26 am

      Sir,
      Thanks for your reply. Can you explain, what exactly do I have to do to Q1 ?

      Reply
    • Ram Patil says

      December 30, 2016 at 6:28 am

      Also I would like to inform you that I am purchased 4 nos. of solar PV panels to connect in parallel, each rating of 250 watt, 24 volt.

      Reply
    • Swagatam says

      December 30, 2016 at 7:37 am

      Ram, you will have to select Q1 such that it is able to handle much above 24V and current in excess of the result obtained by solving 1600/24

      that's great, you can now go ahead with the project….wish you all the best

      Reply
    • Ram Patil says

      January 2, 2017 at 7:07 am

      Hi sir,
      For above specs, can I use 40V, 50A P-CHANNEL POWER MOSFET (UTT40P04) as Q1 ? Or please suggest voltage and current for Q1 and code number if any please.

      Reply
    • Swagatam says

      January 2, 2017 at 11:58 am

      Hi Ram, you can try it, but you will need to mount it on a large heatsink

      Reply
    • Ram Patil says

      January 4, 2017 at 12:19 pm

      What is S1 (Equalise) stands for? I dont get its meaning. Please explain.
      Thanks,
      Ram

      Reply
    • Swagatam says

      January 4, 2017 at 4:02 pm

      you can search it online…."what is equalization in battery charging"

      Reply
  62. Ravipal Singh says

    December 28, 2016 at 10:25 am

    hi sir,can i use this circuit to charge higher ah batteries ,such as 180 amp.or do i need to change some in circuit.

    Reply
    • Swagatam says

      December 28, 2016 at 12:10 pm

      yes it is possible provided Q1 is appropriately rated for handling the specified amount of current….

      Reply
  63. Prabodh says

    December 19, 2016 at 5:47 am

    please give inductor details ie how to built that

    Reply
  64. Swagatam says

    August 31, 2016 at 3:33 am

    It will connect with pin#1….mistakenly not shown in the diagram….

    Reply
  65. Nikhil Gujar says

    August 19, 2016 at 1:45 pm

    Hello sir,

    I want to charge 48 v 175 AH battery with 250 W solar panel . (Mppt voltage 30 v, MPPT current 8 A).
    I want to charge the battery with Mppt and current control. Can above circuit be useful for me?

    Please suggest the solution

    Reply
    • Swagatam says

      August 20, 2016 at 8:35 am

      Hello Nikhil, the above circuit is specified for 24V max, so it cannot be used for 48V application.

      and a 30V 8amp supply cannot be used for charging a 175AH battery with any modification….the current should be at least 25 amps

      Reply
    • Nikhil Gujar says

      August 20, 2016 at 2:27 pm

      Thank you sir for your reply.

      The basic idea is to charge batteries of E vehicle. Limitation is space on roof of vehicle. Maximum 1 panel can accommodate on roof. Though charging current is less but it will keep battery charging whole day. You may please suggest suitable solution.

      Reply
    • Swagatam says

      August 21, 2016 at 5:36 am

      you will need a boost MPPT charger circuit which can boost the solar panel voltage to 48V.

      or you can use an external boost circuit for converting the 30V from the MPPT to 48V @ 5amp

      you can try the last circuit from the following article, and modify the transformer appropriately for getting the desired results

      Reply
    • Swagatam says

      August 21, 2016 at 5:36 am

      here's the link

      https://www.homemade-circuits.com/2013/09/half-bridge-mosfet-driver-ic-irs21531d.html

      Reply
  66. .........PRADEEP........ says

    August 13, 2016 at 11:46 am

    Dear sir
    can u giv ckt diagram and ideas of PWM/MPPt based solar street light charge Controller for 200Wp panel and 200Ah battery

    Reply
    • Swagatam says

      August 14, 2016 at 3:26 am

      Dear Pradeep,

      you can try the following design

      https://www.homemade-circuits.com/2015/11/simple-solar-mppt-circuit-part-2.html

      Reply
  67. naeem says

    June 19, 2016 at 11:07 am

    what maximum current it can handle please

    Reply
    • Swagatam says

      June 19, 2016 at 12:23 pm

      as per the rating of Q1…please check it through its datasheet

      Reply
  68. MadMacs says

    June 13, 2016 at 11:17 pm

    Hi, has anyone built this and do you have any details on the inductor L1, i.e guage of wire, toroid size and number of turns?

    Regards
    Mac.

    Reply
    • Ram Patil says

      January 4, 2017 at 9:58 am

      Hi Mac,
      You will get ready inductor available in market.
      Regards,
      Ram

      Reply
  69. Edwin Parsons says

    February 6, 2016 at 2:10 pm

    Could this circuit be used for charging a 50AH 39.5V battery pack? Would replace the solar panel with a power source cause any issues?

    Reply
    • Swagatam says

      February 7, 2016 at 2:24 pm

      it would be possible, just make sure to change the component values accordingly which are recommended to be changed for the 24V version ….through cross multiplication.

      Reply
      • Doug says

        February 15, 2022 at 5:02 am

        Hi there,
        For a 50amp 12v 3 stage charger, what immediate changes would need to be made?
        I’ve seen ‘smart’ chips that handle all the aspects of LAB (or other chemistries) charging but they all seem to be limited in their output capacity.
        Is there an IC available that would handle higher currents?

        Thanks for any thoughts you might be able to spare.
        Doug

        Reply
        • Swagatam says

          February 15, 2022 at 4:43 pm

          Hi, I don’t think the above circuits can be modified for delivering 50 amp current. Higher current chargers in the order of 50 amps can be perhaps built using discrete components and mosfets, but that won’t be an MPPT.

          Reply
  70. Edwin Parsons says

    February 6, 2016 at 2:08 pm

    Can you see any problems using this circuit to charge 39.5 V 50AH LiFePO4 battery pack?

    Reply
  71. VIJAY AJ says

    February 4, 2016 at 12:35 pm

    Sir can u please explain the function of voltage follower and current follower in the ic2 stage or suggest some other article related to that

    Reply
    • Swagatam says

      February 4, 2016 at 12:48 pm

      Vijay,
      voltage follower is a configuration where the input voltage to the opamp is simply carried forward across its output but after buffering through the opamp so here opamp acts like a buffer.

      the current amplifier monitors the voltage across the sample resistor and switches its output ON or OFF depending upon the set threshold…it's a comparator actually

      Reply
      • Swagatam says

        February 4, 2016 at 12:49 pm

        I have not yet covered these topics in this website, soon I may include these…

        Reply
  72. Shailesh Lokhande says

    January 22, 2016 at 2:37 am

    sir,
    I want to design the same circuit for our mobile battery Having rating 2900 mAH/11.02Wh nominal charge voltage 3.8 V.Limited charge voltage 4.35 V as per any anroid mobile battery.Can I make the charger portable using the same pic based mppt technique or I should go for Linear technology or any other method mppt method to make the circuit portable.
    2.How can I add auto cut off feature in this circuit.

    Reply
    • Swagatam says

      January 22, 2016 at 8:57 am

      Shailesh, according to me it would be an overkill to use the above design for a modest requirement like yours.

      An MPPT might not be required for your application, rather a simple buck based smps charger would be more than sufficient.

      here's one design which is extremely portable, and extremely customizable and might suit your application well:

      https://www.homemade-circuits.com/2015/05/5v-pwm-solar-battery-charger-circuit.html

      for including an auto cut-of you could include the second circuit from the following link in the proposed design:

      https://www.homemade-circuits.com/2011/12/how-to-make-simple-low-battery-voltage.html

      Reply
      • bazy says

        September 28, 2021 at 12:36 pm

        Please sir, wer can i connect RG 2004A display on this circuit diagram to show solar, battery and pwm too.

        Reply
        • Swagatam says

          September 28, 2021 at 1:20 pm

          Bazy, I don’t think the mentioned display can be directly used with the above circuits.

          Reply
          • bazy says

            September 28, 2021 at 1:38 pm

            Ok sir can i add REG2004A on the circuit diagram to show solar bsttrry and pwm on screen ??

            Reply
            • Swagatam says

              September 28, 2021 at 6:30 pm

              It cannot be added or used with the above circuits, it can be used only with an Arduino according to me.

              Reply

Need Help? Please Leave a Comment! We value your input—Kindly keep it relevant to the above topic! Cancel reply

Your email address will not be published. Required fields are marked *

Primary Sidebar

Subscribe to New Circuit Ideas

Categories

  • Arduino Projects (87)
  • Audio and Amplifier Projects (132)
  • Automation Projects (17)
  • Automobile Electronics (101)
  • Battery Charger Circuits (82)
  • Datasheets and Components (102)
  • Electronics Theory (143)
  • Free Energy (37)
  • Games and Sports Projects (11)
  • Grid and 3-Phase (19)
  • Health related Projects (25)
  • Home Electrical Circuits (12)
  • Indicator Circuits (14)
  • Inverter Circuits (87)
  • Lamps and Lights (142)
  • Meters and Testers (69)
  • Mini Projects (46)
  • Motor Controller (64)
  • Oscillator Circuits (27)
  • Pets and Pests (15)
  • Power Supply Circuits (108)
  • Remote Control Circuits (50)
  • Security and Alarm (64)
  • Sensors and Detectors (100)
  • Solar Controller Circuits (59)
  • Temperature Controllers (42)
  • Timer and Delay Relay (49)
  • Transmitter Circuits (29)
  • Voltage Control and Protection (37)
  • Water Controller (36)

Calculators

  • Battery Back up Time Calculator
  • Capacitance Reactance Calculator
  • IC 555 Astable Calculator
  • IC 555 Monostable Calculator
  • Inductance Calculator
  • LC Resonance Calculator
  • LM317, LM338, LM396 Calculator
  • Ohm’s Law Calculator
  • Phase Angle Phase Shift Calculator
  • Power Factor (PF) Calculator
  • Reactance Calculator
  • Transistor Astable Calculator
  • Transistor base Resistor Calculator
  • Voltage Divider Calculator
  • Wire Current Calculator
  • Zener Diode Calculator
  • Filter Capacitor Calculator
  • Buck Converter Calculator
  • Boost Converter Calculator
  • Solar Panel, Inverter, Battery Calculator
  • Wire Current Calculator
  • SMPS Transformer Calculator
  • IC SG3525, SG3524 Calculator
  • Inverter LC Filter Calculator

People Also Search

555 Circuits | 741 Circuits | LM324 Circuits | LM338 Circuits | 4017 Circuits | Ultrasonic Projects | SMPS Projects | Christmas Projects | MOSFETs | Radio Circuits | Laser Circuits | PIR Projects |

Recent Comments

  • Swagatam on Best Electronic Circuit Projects
  • TOMMY on Best Electronic Circuit Projects
  • Swagatam on Inverter Circuit with Feedback Control
  • Jerry Adeosun on Inverter Circuit with Feedback Control
  • Swagatam on Contact

Company

  • Privacy Policy
  • Cookie Policy
  • About Me
  • Contact
  • Disclaimer
  • Copyright
  • Videos
  • Sitemap

Social Profiles

  • Twitter
  • YouTube
  • Instagram
  • Pinterest
  • My Facebook-Page
  • Quora
  • Stack Exchange
  • Linkedin
  • © 2025 · Swagatam Innovations