Hospital Room Call Bell Circuit

The post discusses a simple hospital room call bell circuit which can be installed in hospital patient rooms for allowing the patients to get a quick access to a medical representative or a nurse whenever in need, by simply pressing a call button at the bedside. The idea was requested by Mr. Willy.

The Circuit Request

Hi Mr. Swagatam Majumdar,

Its Willy from Goa,

I want to request to to make a patients room call bell to nurse station circuit
diagram for a 10 bedded hospital.

the circuit can be made as simple as possible with no false triggering and solid
state with no relays and individual reset switch at the nurse station
Thanking you in advance
Willy 

The Circuit Design

In one of my previous posts I discussed a simple office call bell circuit for facilitating an easy and foolproof communication across the rooms and the headoffice.

In this post we discuss a call bell system for hospital installation in order to facilitate communication between the patients and the nurses who may situated in different rooms or destinations across the hospital premise.

 

Hospital Room Call Bell Circuit

 

 

Referring to the above shown hospital room call bell circuit, the idea may be understood as follows:

The transistor T1, T2 basically forms a transistorized latch circuit wherein a trigger at the base of T1 causes the circuit to hold into a latching mode, meaning a single momentary positive pulse at the base of T1 enables T1/T2 to go into a permanent conduction mode until the feed from R3 is grounded by pressing the reset button.

On pressing the button at the patent's end latches the circuit into conduction and causes a DC pulse to be sent through D2 to the connected DC bell.

The bell sounds loudly until the 1000uF capacitor is charged fully, after which the bell ceases to operate.

However the latching action keeps the RED LED switched ON along with the green LED which is supposed to be positioned in the patient's room beside the call button. This LED informs the patient regarding the call been sent and confirms regarding the same. The red LED intimates the nurse regarding the patient's room.

Identical stages as explained above may be repeated and installed for each of the rooms in the hospital for enabling the respective occupants to execute a foolproof interaction with the nurses rooms whenever the patient may be in need for help.

The reset button is provided for enabling the nurse to reset or restore the situation back to the switched OFF condition which also simultaneously tells the patient regarding the response from the nurse's room, so that the patient is able to anticipate the help being on the way.

Parts List for the proposed hospital call circuit

R1 = 100K
R2, R3, R4 = 4K7
C1 = 100uF/25V
D2 = 1N4007
T1 = BC547
T2 = TIP127

Hospital Room Call Bell Circuit using SCR

 

Hospital Room Call Bell Circuit using SCR

 



10 thoughts on “Hospital Room Call Bell Circuit

  1. Have questions? Please feel free to post them through comments! Comments will be moderated and solved ASAP.
    • Hi, The design is a simple transistor latch and will definitely work if implemented correctly.

      do not make the whole circuit together, fist make and test a single T1/T2 stage and check the response by pressing the relevant buttons.

      you can connect a 1uF capacitor across base/emitter of T1 to make sure that the T1 does not get disturbed due to long wires connected with base resistor.

      please first understand the working and then make it.

  2. Hello Swagatam
    I love the circuit , and I am ready to test and build it , few question though
    1. Can I make the button wireless to increase the range
    2. Is it possible to add a receiver display that will be carried along by the nurse which will indicate the button pressed
    3.can I increase button per patient , different assistance , maybe two button per patient and reporting to the nurse differently as per function
    I need to convert the same diagram to Supermarket Supervisor Teller Assistance ,

    Please help

    Thanks

    • Thanks Lufono,

      1) For a wireless operation you will require a Tx/Rx pair on both sides for each button.
      2) for each button you may have to include a separate latch circuit, and for a wireless a more complex circuitry might be required in order to send separate unique signals to the Rx side from each patient.

      So a wireless set up could be extremely costly.

  3. hi I made the simulation of the circuit and finally its working just fine I even included a 555 timer circuit and a buzzer to make it pulse width continuously, but what I notice with my simulation is that 100uf is feeding the collector of my t1 and so even prior to ON the pshbutton1(patient button) the leds will stay ON so I decided to finally remove the capacitor and it works just fine without any false triggering. my question is, is there any problem for removing the 100uF(considering the first circuit with 12VDC).

    • Hi, that is why I never use simulators, how can 100uF trigger anything in the circuit? it is blocked by T1 and T2? that’s rubbish result from the simulator. 100uf is strictly required so that T1 does not get triggered by spurious stray external signals.

      I would advise you to build it practically which will help you to get correct results and you will be able to learn electronics correctly