Dual Battery Charger Circuit with Isolator

The post explores an innovative automatic dual battery charger with isolator circuit for alternators and engines, which allows monitoring of the charge levels of two individual batteries, and switching them across the loads appropriately. The idea was requested by Mr. Daz.

Technical Specifications

Very promising circuits you've always shared, actually I always visit your blog coz im also electronics hobbyist from Philippines ..

i have read many of your posted electronics design especially on battery charging circuits 🙂 its very simple and yet reliable and efficient circuits, building those circuits using your designs works great and thank you so much swagatam!

but until, i was thinking an solid-state automatic dual battery charger isolator for deep cycle agm 100ah batteries, i am using some of your design charging circuits and delay and relay techniques, but unfortunately, always got me an error...



what should I do sir?. can you guide me with my issues? thanks so much.

here is the step of how the circuit may do...

1. before starting, the two agm batteries 1&2 will combine in parallel connections to be used for starting the engine in order to provide smoother and more power to the start.

2.Then, once the engine is started, the battery 1 will automatically disconnect via a relay for automatic fast charging until  float mode is reached.

3.while the battery 2 is connected, a voltage low level cut-off circuit will be monitoring its condition until its voltage reaches 11.5v,4.

When the low volt reaches 11.5v, the circuit will automatically trigger the relay connecting the fully charged battery 1 parallel with battery2.5.

after battery 1 is connected in parallel, a delay relay cut-off will disconnect of battery 2 and engage it for automatic fast charging and to float mode.6.a continuation cycle of relays, monitor, charging. that's it.

I hope you understand of what i mean.

hoping to hear from your sir. i hope you can help me with this circuits to make.

Thank you so much and more power to you sir!

The Design

Instead of addressing the two batteries as battery#1 and battery#2, I thought it was better identifying them as "charged battery", and  "partially charged battery".

The proposed design of an automatic dual battery charger with isolator circuit for alternators may be understood with the following given points:

Initially due to absence of power, the two relays are held at their respective N/C positions which allow the two batteries to get connected in parallel with the load.

How the Batteries are Charged

Let's assume battery#1 as the charged battery, now when the engine is switched ON, both batteries provide their combined power to the alternator via the relevant N/C contacts.

As soon as the alternator starts, it powers the opamp circuit so that the opamps 1 and 2 which are configured as voltage comparators are able to sense the connected battery voltages at their relevant inputs.

As assumed above, since batt#1 has the higher voltage level, triggers opamp1 output high.

This  in turn activates T1 and it's relay, which instantly disconnects battery#2 from the load.

Battery#2 now gets connected with the charger via the N/O contacts and starts getting charged at the relevant current.

At this point T1 executes two actions: It clamps the inverting input of opamp1 and non-inverting input of opamp2 to ground, latching their positions. It means the relays now hold their positions without any further interventions from opamp1 and 2.

In course of time, battery#1 starts getting discharged via the connected loads, and this condition is monitored by opamp3. The moment battery#1 charge reaches around 11.5V set by P2, opamp3 output goes low.

Since opamp3 output is connected to the base of T1, the above triggering instantly breaks T1 conduction resetting opamp1 and 2 into its original situation allowing them to yet again track the battery voltages.

This time battery2 being the one having higher potential activates opamp2/T2 and the lower relay.

The actions quickly disconnects battery1 from the load and connects battery#2 with the load.

Opamp4 now monitors battery#2 condition until its voltage also falls below the 11.5V mark when the situations yet again reverts.

The cycle continues as long as the engine and the load remain in the discussed chain.

The capacitors C1, C2 ensure a smooth transition between the relay switching.

Circuit Diagram

 

As we can see in the above automatic double battery charger with isolator circuit, the relay N/O contacts are responsible for the required charging of the connected relevant batteries.

Since these batteries need to be charged with an "intelligent" charger, the system should be a step-charger kind of unit.

One such circuit has been discussed in this 3 step battery charger circuit, which may effectively employed here for the proposed method of charging both the batteries.

Parts List

All resistors are 1/4 watt CFR

R1, R2, R7, R8 = 10k

R3, R4, R5, R6 = 1M

P1, P2 = 10k presets.

D1, D2 = asper load current.

D3---D8 = 1N4007

All zener diodes = 4.7V, 1/2 watt

T1, T2 = 8050

C1, C2 = 220uF/50V

Relays = SPDT, 12V, 30 amps contacts

Opamps = LM324 (see datasheet)

Note: Connect the emitters of T1/T2 to ground through 1N4148 diodes, this is important otherwise the opamp3/4 outputs won't be able to switch OFF the BJTs correctly.

Dual or Double Battery Charger using IC 555

The following paragraphs explain a simple automatic double battery charger circuit from a single power supply. The idea was suggested by "Superbender" Let's learn the details.

Technical Specs

Thanks for the great circuits. I am looking forward to start putting one together for hibernating my RVs battery over the winter.

However, can I exchange the transformer + diode bridge with the +15V DC power output from an old PC power supply, i.e a switched power supply?

I don't see any reasons why not, but don't know too much about the charging restrictions for 12V Lead Acid Batteries.

I think I'll be moving down the path with a switching power supply that is rated for 5A max current. However, I am wondering if I can charge 2 batteries at the same time.

I have an older VW camper that has an auxiliary battery as well as a starter battery.

Over the winter I'd like to keep both batteries happy and your schematic seems to be promising to achieve that. The batteries are not connected to each other when the car is off.

Do you think it is possible to use only one power supply, but two NE555 schematics to achieve this? I am thinking that I could use one NE555 schematic per battery, probing for voltage levels and controlling individually when each battery is charged.

I am also thinking to put a diode into the current path to the battery so that, when both batteries are charging, the current can never flow from one battery to the other.

According to the spec sheet, the 44 Ah auxiliary battery that I am going to buy has a max charging current of 12A.

The other battery should have about 75Ah capacity. My interpretation of those values is that both batteries can handle the full 5A current when only one is charged.

If both are charged simultaneously, they'd simply take longer and current will distribute itself according to the voltage levels of the battery.

Obviously I am trying to prevent buying two switching supplies (the PC power supply actually didn't offer 15V when I checked), which would keep the cost to a very interesting level => ~$30 vs. ~$55 for a system with two PS or vs. about $90 for buying two chargers.

Looking forward to your thoughts on this.

Thanks again
Superbender

The Design

The  proposed automatic double battery charger circuit from a single power supply shows two identical stages made by using the IC555. These stages are basically responsible for controlling the lower and upper charging thresholds of the connected batteries.

The SMPS which is the common power source for both the 555 stages supplies power to the batteries via the individual diodes and the relay contacts of the respective 555 stages.

The diodes make sure that the power stay well isolated from the two stages.

However the crucial part of the circuits are the two resistors Rx and Ry which are the current limiting resistors for the two stages.

These resistors ensure the correct specified amounts of current to the respective batteries  This further ensures that the SMPS is loaded uniformly across the connected batteries.

Rx and Ry should be calculated as per the AH ratings of the batteries with the help of Ohm's law.

Schematic

Another Simple Split Battery Charger

In the following paragraphs we investigate another interesting twin or split battery charger circuit with auto-changeover illustrates a method through which two 12V lead acid batteries can be charged and discharged in tandem by switching them appropriately across the charging voltages and load alternately.

This ensures that the load receives a continuous supply of power irrespective of the actual source conditions such as a solar panel, wind generator etc. The idea was requested by Mr. Mohammad Zain.

Design Objective

I am looking for a automatic 12 volt lead acid battery charging circuit, Which indicates when the battery is full and when it is out of charge.
Or if you can help me design a charging circuit that will use two batteries that is it will charge one battery at a time so when it gets full it will switch to the other battery
Your help will be really appreciated .

Working Details

The discussed split battery charger can be studied through the following detailed explanation:

Referring to the circuit diagram, two identical opamp stages A1/A2 can be seen incorporating the IC LM358. Both the opamps are rigged as voltage comparators.

A1/A2 are basically configured to detect the over voltage and low voltage thresholds of the respective batteries and to switch the corresponding relays for initiating the required cut-offs when the relevant conditions are detected. This is sensed with reference to their inverting input voltage levels fixed at the corresponding zener voltages.

The over charge cut-off threshold is set by appropriately adjusting the 10k preset associated with the non-inverting inputs of the battery.

The feedback resistor across the outputs and non-inverting inputs of the opamps determine the hysteresis levels which in turn decide the low battery restoration so that the relevant batteries begin charging once the corresponding lower thresholds are crossed.

Suppose battery#2 is initially fully charged, and battery#1 is being charged through the N/C of the A1 relay stage.

The connected load at this situation receives the voltage through the N/O of A2 relay since it's already in a disconnected state due to full charge condition of battery#2.

Now let's assume after a period of time battery#1 gets fully charged, A1 output goes high triggering the connected relay driver stage which disconnects the charging voltage to battery#1 by shifting from N/C to the N/O contact.

At this instant both the batteries get connected with the load reinforcing the supply to the load.

However, sooner or later battery#2 reaches its lower discharge threshold, forcing A2 to restore the charging process by flipping its relay from N/O back to N/C.

Battery#2 now gets into the charging phase leaving battery#1 to handle the load, the operations keeps repeating as long as the system stays switched ON.

For ensuring a balanced switching responses from the two stages one battery must be completely discharged while the other fully charged at the beginning when the proposed twin battery charger circuit is first initiated.

Circuit Diagram

Twin or Split 12V Battery Charger Circuit with Auto-Changeover

The above explained selectable 12V battery charger circuit was built and tested successfully by Mr. Dipto a dedicated member of this blog.

The implementation details may be witnessed in the following images of the prototype, sent by Mr. Dipto.

 

SHARING IS CARING!


About the Author

I am an electronic engineer (dipIETE ), hobbyist, inventor, schematic/PCB designer, manufacturer. I am also the founder of the website: https://www.homemade-circuits.com/, where I love sharing my innovative circuit ideas and tutorials. If you have any circuit related query, you may interact through comments, I'll be most happy to help!



30 thoughts on “Dual Battery Charger Circuit with Isolator”


  1. Howdy, Friend! Interested to Learn Circuit Designing? Let's Start Discussing below!
  2. Hello.
    Mr. Swagatam, the issue on the above circuit diagram. How will the
    transistor stage be used to replace the diodes at 3/4 of the op-amp i.e
    if you can please give an update on the circuit diagram.thank you.

      • Mr Swagatam:

        I have been a fan of your site for awhile and have found uses for some of your circuits, one such circuit is the one that Mr Dipto posted. I am a ham and have two batteries that I would like to use this circuit for (dual charger that charges one battery then the other) charging my batteries however I would like to use Mosfets instead of normal relays. Can you help me with this please? Thank you for whatever help you can give.

        Joel

  3. Sir, i need an automatic charger with selector switch individually to charge, if one battery to charge by clicking the selector switch to 1 for just one battery, for two batteries selector to 2, so on and so forth.. are individual batteries having a different charging amperage? please help me with these sir thank you….

    • sir i need an automatic charger, capable to select from one battery to 10 batteries, with LED indicator for power and battery full. (optional: with analog amp meter).. kindly help me with these… thank you sir!

  4. Good evening Swagatam,
    Great Blog, very interesting and worthwhile. Very impressed.
    I have a question in regards to this automatic dual battery charger circuit. I am an avid camper and enjoy getting out and about for long periods camping. I would like to be able to charge by dual batteries in my 4WD by either alternator with engine running, as per this circuit, but also from wind turbine and solar panels. The wind turbine is a DC one with built in charge controller and solar panels also have charge controller. Would this circuit work correctly, if I simply built it 3 times, one connected to alternator charge current, one to solar charge current, and one to wind turbine charge current, but all connected to batteries? I wonder if the battery voltages being sent to the circuit for sensing purposes, would be al stuffed up if the batteries were being charged by another charging source?
    All help is much appreciated.
    Regards
    Dave

    • Thanks so much Aussie,

      Yes the above design could be used for your requirement by adding a third identical stage, but there's even a simpler option of implementing the same through a method shown in the following circuit:

      https://homemade-circuits.com/2014/05/twin-or-split-battery-charger-circuit.html

      The idea is less complex and the stages are easily distinguishable.

      Here too you may want to add an additional identical stage for integrating the third battery through the third energy source.

      The circuit employs separate relays and diodes for the individual connected batteries, so there's no chance of the voltage lines getting mixed up with each other, and therefore the isolation can be considered extremely safe:)

    • …the diagram in the link shows a common supply fed to the relays N/C contacts which are rigged up together as a common terminal, for your application the N/C contacts of each relay would need to be separately terminated to the available energy.

  5. Hi! Sir. Can you tell of how to post a comment on your post? I try to comment a question on your blog 1.5v to 12v converter, but my comment didn't appear. what is the problem sir?

  6. hello sir,
    awesome!
    what is Antonio circuit(some thing like this). my teacher asked today. don't know about it.Google doesn't help much

    also sir,how many post where there before you apply for ad-sense

    thank you
    alwals enjoyed your post
    keep it up!
    regards
    tushar

  7. hi swagatam,

    whoaa what a quick respose! thank you so much my friend.. will do now then the construction, ill be back to you once this made and im not forget what i promised. thanks you so much! more power!

    kind regards,

    daz

    • Thanks Daz,

      I appreciate your kind gesture, if it works successfully for you that would be more than enough for me….I am not expecting any sort of compensation for this, feel free to ask me if you have any doubts while you make it, we'll solve it together.

Leave a Comment