• Skip to main content
  • Skip to primary sidebar

Homemade Circuit Projects

Need circuit help? Post them in the comments! I've answered over 50,000!

Blog | Categories | About | Contact | Calculators-online
You are here: Home / Voltage Control and Protection / Mains AC Overload protection Circuit for Voltage Stabilizers

Mains AC Overload protection Circuit for Voltage Stabilizers

Last Updated on January 2, 2024 by Swagatam 104 Comments

In this article I have explained how to make a cheap yet effective mains operated AC overload and over-current protector circuit using very ordinary discrete components.

Table of Contents
  • Introduction
  • The Importance of an Overload Protection Circuit
  • How it Works

Introduction

I have published a few mains voltage stabilizer circuits in this blog, these units are designed and intended for safeguarding the connected appliances at their outputs.

However these equipment lack one protection which is the overload protection.

The Importance of an Overload Protection Circuit

A particular stabilizer unit may be rated for handling a maximum specified limit of power, beyond which it's effects may start diluting or might become inefficient.

Overloading a voltage stabilizer might also result in heating of the transformer and fire hazards.

A simple circuit shown below may be incorporated with a stabilizer circuit or any such protection circuit for reinforcing the safeguarding capabilities of the units.

How it Works

The diagram shows a very simple and straightforward configuration where only a couple of transistors and few other passive parts are used for forming the intending design.

The mains stabilized AC is derived from the stabilizer outputs and allowed to switch through another RL1, via its N/C contacts.

One of the wires of the AC mains connections is added with a series resistor of a calculated value.

As the load across the mains output increases, a proportionate magnitude of voltage starts developing across this resistor.

The value of the resistor is so selected that the voltage across it becomes just enough to light up a connected LED in response to a load that might be considered as dangerous and over the maximum tolerable limit.

When this happens, the LED just lights up, an LDR positioned and enclosed in front of the LED instantly drops its resistance in response to the illumination generated by the LDR.

The sudden reduction in the resistance of the LDR, switches ON T1 which in turn switches ON T2 and the relay, initiating the latching effect of the circuit and the relay.

The load or the appliance at the output is thus immediately switched off when an overload situation is detected.

The whole action takes place within a fraction of a second, giving no chance for any untoward consequence and the whole system is safeguarded by the inclusion of this simple AC mains overload protection circuit.

Formula for Calculating Current limiting Resistor

R1 = 1.5 / I(intended current limit),

For example if I =15 amps, then R1 = 1.5/15 = 0.1 Ohms, and it's wattage will be 1.5 x 15 = 22.5 watts

Mains AC Overload protection Circuit for Voltage Stabilizers

Parts List

  • All resistors are 1/4 watt 5% except R1 (see text)
  • R4 = 56 ohms
  • R4, R7 = 1K
  • R5 = 10K
  • R6 = 47K
  • P1 = 100K preset
  • Diodes = All are 1N4007
  • T1 = BC547
  • T2 = BC557
  • C2 = 10uF/25V
  • LD1 = red LED 20 mA
  • Relay = 12 V/200mA 30 amps

The LED/LDR device can be assembled manually as per the following example image

LED LDR

You'll also like:

  • 1.  SCR/Triac Controlled Automatic Voltage Stabilizer Circuit
  • 2.  Triac Phase Control using PWM Time Proportional
  • 3.  Power Factor Correction (PFC) Circuit – Tutorial
  • 4.  USB 5V To 24V DC to DC Boost Power Regulator Module
  • 5.  SMPS Voltage Stabilizer Circuit
  • 6.  Adjustable Voltage Regulator Circuit using LM324 IC with Over Current Protection

About Swagatam

I am an electronics engineer with over 15 years of hands-on experience. I am passionate about inventing, designing electronic circuits and PCBs, and helping hobbyists bring their projects to life. That is why I founded homemade-circuits.com, a website where I share innovative circuit ideas and tutorials. Have a circuit related question? Leave a comment.... I guarantee a reply!

Previous Post: « 2 Easy Automatic Inverter/Mains AC Changeover Circuits
Next Post: Easiest Single Axis Solar Tracker System »

Reader Interactions

Comments

  1. , Shafiq says

    September 20, 2023 at 9:09 am

    What can I do to reduce the electricity bill?

    Reply
    • Swagatam says

      September 20, 2023 at 11:07 am

      Use LED bulbs for all the lamps and reduce the fridge setting to minimum, don’t use geyser too often.

      Reply
  2. Godfrey says

    July 13, 2022 at 11:10 pm

    Dear sir,
    Please sir, help me with an Ac circuit that can protect 220V Ac led bulbs, flat screen Tv etc from over voltage/current condition from the Mains supply.

    Reply
    • Swagatam says

      July 14, 2022 at 9:21 am

      Godfrey, for this you will have to install a voltage stabilizer unit which can regulate the voltage for the loads. Or you can also build an over voltage cut off circuit as explained in the following article:

      https://www.homemade-circuits.com/highly-accurate-mains-high-and-low/

      Reply
      • Godfrey Godfrey says

        July 14, 2022 at 9:15 pm

        Okay sir
        Thank you very much

        Reply
  3. Girish says

    April 27, 2021 at 4:04 pm

    Operating supply is 12v think, coz not define in schematic.

    Reply
    • Swagatam says

      April 27, 2021 at 5:15 pm

      yes can be 12V or 6V depending on the relay coil voltage

      Reply
  4. Mohamed farook says

    December 20, 2020 at 9:28 am

    Hello sir , have a nice day ,
    Sir I need a circuit diagram for Overload , No load protection for 1 hp submercible Motor . used by current transformer .
    thanking you .
    with regards ,
    Mohamed farook .

    Reply
    • Swagatam says

      December 21, 2020 at 5:15 pm

      Hello Mohamed, if possible I will to design it and post it here:

      Reply
  5. A Narwekar says

    December 13, 2020 at 8:35 pm

    R1 dissipates a lot of power. Could you suggest a way to reduce this?

    Reply
    • Swagatam says

      December 14, 2020 at 8:35 am

      Try the following modified diagram using a standard opto”
      comment image" alt="mains overload cut off circuit" />

      Calculate R1 in the following manner:

      R1 (Ohms) = 1 / Max current limit (Amps)
      Wattage = 1 x Max current limit

      Reply
      • Sak says

        December 29, 2023 at 4:21 pm

        Thanks for your update, and here I am. In my last comments I raised my doubts and you directed me here. As comparing main article’s diagram, this one looks more promising. However after observing the relay contacts I have yet some more concerns:
        1). I think In some other post, I read about HYSTERESIS, how it is handled in this circuit. In case the HYSTERESIS is still a problem then IC based circuit shall resolve it or just the transistor circuit as above.2). If for some reason i.e. the power to above circuit is not working etc. the circuit may turn on the load but Overload protection may remain absent. Is it possible to make it work the opposite way i.e. Appliance in Normally Open contacts of the relay so circuit Must Turn On to enable the load. In this case if something is wrong with circuit so default state for load is to be off.
        3). Do you have something similar in solid state form. Powered directly from 220v and doing the above as well?
        4). Am I right about the R1 being a steel wire resistor? Is it available ready made or I have to work it out myself?
        5). Is it possible to keep the calculated resistor to a fixed load i.e. 100 watts and change circuit in a way so it can trip for 10, 50 or 100 watt without changing resistor.

        Thanks for your patience and help.

        Regards

        Reply
        • Swagatam says

          December 29, 2023 at 6:59 pm

          Thank you for posting your questions here.
          1) The HYSTERESIS aspect may not be relevant here, because when an over current situation is detected the relay and the circuit get latched, and remain in the latched position until the circuit is reset manually.
          2) That’s a good point and can be solved easily with some minor modifications in the design. For this, the positions of the opto-coupler and the push-button/P1 need to be swapped with each other. The P1 actually can be entirely removed with only the push button staying in the new position for initiating the circuit manually. The push button will need to have a series 2.2M resistor for protecting the T1 base.
          3) That might be possible by replacing the relay coil with the input of an SSR circuit. You can find a few good SSR circuits in the following post: https://www.homemade-circuits.com/efficient-electronic-relay-ssr-circuit/
          4) R1 does not need to be a steel wire, it can any ready made wire wound resistor rated at 20 watt or above.
          5) That may be possible by adding a preset control parallel with R1. This preset value can be adjusted to vary the load current threshold for the opto coupler.
          Let me know if you have any further questions!

          Reply
      • Sak says

        January 3, 2024 at 6:58 pm

        Thanks for all your replies. My current motor is of 50 watts , 220v specs so I calculated Amps as 60w /220v = 0.273 A so R1 resistance is 3.66 Ohm = 1 / 0.273. I calculated with an additional tolerance of 10w thus total as 60W however the resistance seems high and shall dissipate too much heat (around 50w). I may found it as an aluminum body power resistance but during 30 to 40 minutes operation of spinner motor it may get too hot. Is all calculations are right and I have to go through this route? Thanks and regards

        Reply
        • Swagatam says

          January 3, 2024 at 7:22 pm

          Here, for the voltage we have to consider the voltage across the resistor which should be around 2V, for properly illuminating the optocoupler LED.
          So, R = 2 / 0.273 = 7.32 Ohms
          Power = 2 x 0.273 = 0.546 or maybe 1 watt.
          The power rating looks weirdly small but I cannot see anything wrong with the calculations.
          If you are not comfortable with 1 watt you can increase it to any other higher value.

          Reply
          • Sak says

            January 4, 2024 at 3:54 pm

            Thank you so much for an example as it cleared out all ambiguity and I do remember Ohm’s law as well. Now I clearly understand I can use a germanium transistor for a V = 0.3, or a silicon transistor for V=0.7 etc. and subsequent lowering resistance as well. Moreover I got confused by resistance power rating. I think I can now use a carbon resistance to check this whole idea and in final design a wire wound resistor may suffice. Well let me experiment it on a bread board first. Moreover how do we suggest a fuse rating for a 50 watt 220v washing machine motor, is there any formula? Regards

            Reply
            • Swagatam says

              January 4, 2024 at 7:01 pm

              Thank you Sak, Glad it helped.

              let me know how it goes.

              Fuse rating is actually quite easy to calculate, for 50 watt 220V, the fuse rating can be:

              50 / 220 = 0.227 amps, if we provide slight more margin, it can be rated at 0.250 amps or 250 mA.

              Reply
              • Sak says

                January 5, 2024 at 3:45 pm

                OK, since an inductive load was involved so the inrush current. For the sake of completeness and helping some other needy, a complete discussion regarding motor inrush current is available in this article. So suits the overall situation more :
                https://www.homemade-circuits.com/mains-over-load-protector-circuit-for/
                Regards

                Reply
                • Swagatam says

                  January 5, 2024 at 6:42 pm

                  Thanks for the suggestion, it looks more appropriate for your application.

                  Reply
              • Sak says

                January 5, 2024 at 3:49 pm

                Another important importation I was looking for was to suppress arching at relay contacts and I have found it also:
                https://www.homemade-circuits.com/prevent-relay-arcing-using-rc-snubber-circuits/
                Thanks for all these important building blocks.

                Reply
                • Swagatam says

                  January 5, 2024 at 6:44 pm

                  Thanks! yes, one of those concepts can be used for suppressing relay arcing.

                  Reply
              • Sak says

                February 6, 2024 at 7:26 pm

                Dear Swagatam

                I have tried to checked the above concept and put a resistance in series with motor and it smoked away (as per above discussion, it was being calculated with a 50 watt motor). I have then checked the spinner motor with Amp meter and my readings are as below:

                1): Spinner Motor without any Load:
                ==========================
                1.2 to 1.2 Ampere as startup and after 1 second keeps fluctuating and after 8 seconds settles down to 0.75 Amps

                2): Spinner Motor with Load:
                ====================
                Startup 1.3Amps and immediately settles down to 1.2 Ampere and stays there (measured for 8 seconds).

                With above facts my new calculated resistance should be R=1.5Ohm with V=2 and Amp = 1.3. My problem is that there is very slight difference between 1.3 Amp to 1.2 Amp or 1.1 Amp.

                Q.1)-The voltage drop remains enough to illuminate an LED whether its 1.2 or 1.3 Ampere? Circuit should turn off in either case, how to correct it?
                Q.2)-Since resistance is fixed at 1.5 Ohm then as per calculation, if Ampere goes down then resistance value is changed as well in formula but in real world with a fixed resistance how does it behave?

                Regards

                Reply
                • Swagatam says

                  February 7, 2024 at 9:03 am

                  Hi Sak,
                  Which type of resistor did you use. You must use a wire-wound resistor which will never smoke.
                  Also, if the motor starts with a high current initially and then drops to a lower value, then that is again a problem, because the circuit will trip at the start up. In that case we have to bypass the resistor for a few seconds during start up.
                  Since opto coupler sensor is not very accurate so the cut off cannot precisely be be at a fixed current, there may be some variations.
                  If you don’t want a fixed resistor as the sensor, you can add a rotary switch with multiple calculated resistors and then select the appropriate resistor as per the load current.
                  Q1.”The voltage drop remains enough to illuminate an LED whether its 1.2 or 1.3 Ampere?”
                  Ans. LED brightness will vary according to the varying current. At 1.2A the brightness might be dim which might increase at 1.3A. At what point the circuit trips that must be verified with experimentation.
                  “Circuit should turn off in either case, how to correct it?”
                  Ans: Circuit will trip only when the LED brightness is just sufficient to switch ON the circuit and this cut-off threshold would be approximately fixed.
                  Q.2)-“Since resistance is fixed at 1.5 Ohm then as per calculation, if Ampere goes down then resistance value is changed as well in formula but in real world with a fixed resistance how does it behave?”
                  Ans: With one fixed resistor you can have the cut off only for a particular current level. If you want the cut off at different current levels then you may have to use a selector switch to select different resistors.

                  Reply
                  • Sak says

                    February 7, 2024 at 6:23 pm

                    Thanks Swagatam. Great explanation.

                    Reply
                    • Swagatam says

                      February 7, 2024 at 7:08 pm

                      My pleasure, Sak.

              • Sak says

                February 6, 2024 at 7:53 pm

                PS: After answering my earlier question, I have one more question. as per stated motor ampere facts, what should be the overloading ampere cut off i.e. 1.5, 1.6 or 2 ampere? Do some kind of theory exists for that as well?

                Reply
                • Swagatam says

                  February 7, 2024 at 9:07 am

                  It depends on the motor current specifications. The overload current can be around 20% more current than the normal current rating of the motor.

                  Reply
          • Sak says

            January 4, 2024 at 6:37 pm

            Dear Swagatam,
            I have observed that many AC motors have a centrifugal switch which is used to disconnect the capacitor + motor running coil after motor’s shaft have some momentum built however I have observed that Spinner/ Dryer 50W motor has no such switch? It is stated that in AC motors if this particular switch does not open the contact switch then continuous power to running coil burns it. What spinner motor has no such switch? Thanks and Regards

            Reply
            • Swagatam says

              January 4, 2024 at 7:08 pm

              Thank you Sak, for the interesting information.
              Yes, you may be correct. However I cannot confirm this, because I do not have sufficient knowledge of centrifugal switches.

              Reply
          • Sak says

            January 4, 2024 at 6:59 pm

            Ok, I have found out that there are different types of AC motors and perhaps my motor is “Permanent Split Capacitor (PSC) Motor” which does not need a centrifugal switch. Am i right? regards

            Reply
            • Swagatam says

              January 4, 2024 at 7:10 pm

              That’s correct Sak,
              A permanent split capacitor (PSC) motor does not require a switch because it has a permanently connected capacitor that is always in the circuit.

              Reply
    • A Narwekar says

      December 14, 2020 at 9:22 am

      Thank you!

      Reply
  6. arun says

    December 17, 2019 at 4:36 pm

    Dear,
    I plan to connect it to 5kva stabilizer, and cutoff watts will 4700watts @240v,
    please advise the value and watts for R1 resistor, please tell me what is the alternative option if specified R1 resistor is not available…

    Reply
    • Swagatam says

      December 17, 2019 at 6:34 pm

      You can create R1 by adding many high watt resistors in series/parallel combination, until you reach the correct desired value….

      Reply
      • arun says

        December 23, 2019 at 5:50 pm

        Sir ,

        please advise the value and watts for R1 resistor,i am planning to build 5kva stabilizer, and cutoff watts will 4700watts @240v

        Reply
        • Swagatam says

          December 23, 2019 at 8:36 pm

          Arun, please see the formula and the example solution at the end of the post. In your case “I” will be 5000/240 = 21 amps, now please calculate the rest.

          Reply
  7. Abioye says

    February 20, 2018 at 9:04 pm

    sir is can you explain what led/LDR means because i dont have enough knowledge about electronic parts or is it found in chargers.
    can i get the part number for the LDR thanks

    Reply
    • Swagatam says

      February 21, 2018 at 9:41 am

      To make this, you have to pack an LED and LDR face to face inside a light proof box….or you can simply use a ready made opto coupler.

      LDRs do not have any number.

      Reply
  8. Solomon says

    January 7, 2018 at 2:26 am

    Hello sir, is it possible to modify this circuit by adding a delay timer for automatic restarting? If yes, pls throw more light to that. Thanks.

    Reply
    • Swagatam says

      January 7, 2018 at 7:35 pm

      Hello Solomon,
      it is possible, you can integrate the 3rd circuit from the following link with the collector of the above circuit, and get the required results

      https://www.homemade-circuits.com/simple-delay-timer-circuits-explained/

      I hope you will know how to do it

      Reply
  9. Solomon says

    January 5, 2018 at 2:19 pm

    Hello sir, can i use TRIAC instead of relay, if yes how can i connect the pin

    Reply
    • Swagatam says

      January 5, 2018 at 7:38 pm

      yes it is possible, I will to update it soon…

      Reply
  10. Saqib Lodhi says

    October 24, 2017 at 6:23 pm

    Hi Swag,

    Will this also help in short circuit?

    also I have both MCT2E (6pins) and PC817 (4 pins). which one should I use for better detection?

    I know PC817 is most used in many power supply circuits and MCT2E is absolute i think.

    Reply
    • Swagatam says

      October 24, 2017 at 7:46 pm

      Hi Saqib, yes it will also safeguard against a short circuit.

      any opto coupler can be used here, although in the diagram an LED/LDR hand built opto is shown, an LED/transistor opto will also work.

      be sure to check and confirm the stages separately while setting up the design.

      Reply
    • Saqib Lodhi says

      October 24, 2017 at 7:55 pm

      Thanks. Will update you with experiments.

      Reply
      • Swagatam says

        October 24, 2017 at 9:09 pm

        OK thanks!

        Reply
  11. Godson says

    September 14, 2017 at 8:00 am

    Hello sir Swagatam,
    Please I have one more question on this schematic. Can I connect the positive rail of the schematic to the same 12V regulator that is supplying the inverter driver without it affecting anything?

    Reply
    • Swagatam says

      September 14, 2017 at 11:13 am

      Hello Godson, yes you can do that without any problems

      Reply
    • Godson says

      September 14, 2017 at 11:44 am

      Ok sir. Thank you very much.

      Reply
      • Swagatam says

        September 14, 2017 at 2:59 pm

        you are welcome!

        Reply
  12. Godson says

    September 1, 2017 at 10:22 am

    Replying to your response…
    So for example, supposing I build a 2KVA inverter which I want to use for a maximum load of 1,600W.
    Shutdown current = 1,600/220 = 7.27A
    R1 = 2/7.27 = 0.28Ohm
    R1 wattage = (1.2 + 2) x 7.27 = 23W (approx)
    Is this correct sir?

    Reply
    • Swagatam says

      September 1, 2017 at 12:37 pm

      yes, that looks correct to me!

      Reply
      • Swagatam says

        September 1, 2017 at 12:39 pm

        sorry, you must include 1.2V also in the R1 formula….

        R1 = (1.2 + 2) / 7.27

        Reply
        • Godson says

          September 1, 2017 at 9:08 pm

          Ok,
          So R1 = (1.2 + 2)/7.27 = 0.44ohm
          And wattage = 23W as above.
          Is that right sir?

          Reply
          • Swagatam says

            September 2, 2017 at 2:07 am

            yes that’s right!

            Reply
      • Godson says

        September 1, 2017 at 2:26 pm

        Alright sir. Thank you so so much. I do appreciate you sir.

        Reply
        • Swagatam says

          September 1, 2017 at 4:19 pm

          you are welcome Godson!

          Reply
  13. maruti more says

    May 26, 2016 at 12:49 pm

    Hello sir,
    I made this circuit and I use 230v a.c. as I/p and 300w o/p. R1- 0.56/2w
    but circuit didn't work.

    Reply
    • Swagatam says

      May 26, 2016 at 4:20 pm

      Hello Maruti, it will be difficult for me to guess what mistake you might have done in your circuit, please read the article and check what might be missing in your circuit

      Reply
  14. Unknown says

    May 26, 2016 at 12:46 pm

    Sir, in this circuit u used stabilizer o/p as circuit i/p.
    Can i apply direct 230v ac in I/p?
    If I can then how I select all components?

    Reply
  15. anmol mishra says

    May 5, 2016 at 7:32 pm

    Hello sir I m anmol from Lucknow
    I started STYBLIZAR menufecturing as a business will u help me for my business technical support I need your help my watsup no. 08115720798

    Reply
    • Swagatam says

      May 6, 2016 at 5:50 am

      Hello Anmol, phone or wattsapp communication may not be possible, but you can consult the issues through email, I'll try to help.

      Please make sure to write the questions in proper English and elaborately because I would be publishing it in my site also.

      Reply
  16. Sivaraj Palanichamy says

    May 1, 2016 at 7:49 am

    Brother actually p1 is for sensitivity only know, i need to adjust current limit resistor? And the above circuit is only for overload current limit, also i need a under load current limit circuit?

    Reply
    • Swagatam says

      May 1, 2016 at 8:42 am

      Brother, at lower P1 setting the circuit will activate at higher currents, and at higher P1 value it will operate at lower current….so it can be used effectively for setting up current.

      for under current cut off we might require two opamp circuits, one for controlling the upper limit and other for the lower limit….I'll think about it.

      Reply
  17. Sivaraj Palanichamy says

    April 30, 2016 at 2:47 pm

    Dear Brother i need under and overload protection circuit for my openwell submersible water pumb 5hp 4kw 415v 10amp , for that i have to use variable protection should be 5amps to 20amps? if you have any circuit like this? Or pls design a circuit for me? If you need some more details pls ask me…

    Reply
    • Swagatam says

      May 1, 2016 at 4:03 am

      Dear Brother, the above design already has an adjustable feature in it through P1, you can set P1 to different positions for achieving any desired cut off point

      Reply
  18. mayoor says

    April 22, 2016 at 7:06 pm

    Please there is a small confusion about the actual constant need for calculating various values of R1.. The post said 1.5 you said it is 2 and later said 3 so please explain the changes. Thanks

    Reply
    • Swagatam says

      April 23, 2016 at 12:23 pm

      Here's the formula

      R1 = LED fwd drop value / cut-off current value

      Reply
  19. Nikhil Kachare says

    April 19, 2016 at 4:28 pm

    Hiee sir
    Can u tell about any circuit that will convert DC to ac (square wave).
    Without using transformer.

    Reply
    • Swagatam says

      April 20, 2016 at 11:49 am

      Hi Nikhil, you can use the circuit which is shown in this article:

      https://www.homemade-circuits.com/2014/01/simplest-full-bridge-inverter-circuit.html

      Reply
  20. mexzony says

    August 14, 2015 at 6:02 pm

    Hello sir
    I don't quite get how vijay set up the 1ohm 20w and the 10k preset.
    Then what value can we use for P1.
    Also there seem to be some confusion as to how to calculate R1 value as I read through the comments.

    Reply
    • Swagatam says

      August 15, 2015 at 3:49 pm

      Hello Michael, the delay effect shouldn't be so critical actually….and yes all the above parameters will interact some and influence the delay effect, so it may require a little experimentation until the right delay is determined…

      Reply
      • adelusi oluwatosin says

        February 17, 2016 at 12:51 pm

        Sir assuming i want to use this circuit for 3kv inverter overload protection how could i calculate R1? sir the relay connection it seem not clear well to me, first, connection to coil terminal is not show in the circuit,secondly, N/O terminal and N/C seem some how confusion. Thanks, hope to hear from you soon.

        Reply
        • Swagatam says

          February 18, 2016 at 2:41 am

          Adelusi,

          the formula is given in the article, please use it to calculate. the current limit in the formula could be calculated by dividing 3kv with the voltage.

          please click the diagram to enlarge, you will be able to see both the contacts although slightly faded, but anyway the N/O is unconnected so its not important, the N/C is the one which is associated with the load and the current.

          Reply
      • adelusi oluwatosin says

        February 17, 2016 at 12:56 pm

        sir please kindly help me design a 12vdc to 36vdc converter.sir i am ready for any output services rendered.

        Reply
        • Swagatam says

          February 18, 2016 at 2:50 am

          you can try any IC 555 based boost converter circuit or 555 IC based flyback converter circuit, please Google this you will find many

          Reply
  21. mexzony says

    August 14, 2015 at 5:09 pm

    Hello Sir
    Just stumbled upon this post.
    Since vijay made it work then I think I can use it as an overload protector with some changes
    1) I get rid of the relay and instead pass the positive signal from collector of PNP transistor to pin10 of my sg3524.
    2) while I am studying the other post you referred me to this one looks more sophisticated.
    3) where and how will I include a time delay before passing to in 10 of IC so the when the current goes above the limit it first gives a de lay of say 5secs and if load does not reducez current then it shuts off inverter
    4) if per adventure the load settles to normal like in the case of surge loads capacitor should discharge rapidly so that it does not trigger shut down since starting current has reduced to normal

    Reply
    • Swagatam says

      August 15, 2015 at 3:04 pm

      Hello Michael,

      for including a delay effect, you can simply add a high value capacitor across the base and ground of T1…make sure the signal from the opto comes through a resistor if you are using an opto coupler…this resistor value can also be tweaked for setting the delay response

      Reply
  22. Vijay says

    May 12, 2015 at 9:41 am

    Hi Swagatam,

    I redesigned this circuit and assembled. As my stabilizer is 1KVA and it can handle 4A, I have used a 1ohm 20W resistor as the voltage sensor. I know this is a little high value but I have created a voltage divider using a 10K preset and adjusted the voltage so that only at 4A the optocoupler is triggered. Even that's not perfect because even a tiny current through the optocoupler triggers T1. To mitigate this I played around and connected a 100K resistor between the optocoupler and T1 base. I tried the 4A current using an induction stove, set the power at 1000W, and I measured exactly 4A using a multimeter. This seems to work fine. When I increase the power to 1200W, it triggers.I haven't yet tried 1050W, 1100W etc yet, which I'll do a little later. While doing this, I found another issue; when I connect the output to my voltage stabilizer (already assembled using one of your circuits but this is 500VA), because of the inrush current to the autotransformer, the circuit triggers. I mitigated this issue by connecting a 47mf capacitor (anything less doesn't do the trick) between P1. Now when I increase the power to 1200, the circuit triggers but takes about 1 second to do so.

    I have one query: Since this circuit allows a second of over current, will it damage the autotransformer? I feel it can take more current than it is rated at for some time but I just wanted to be sure.

    Thanks,
    Vijay

    Reply
    • Swagatam says

      May 12, 2015 at 12:07 pm

      Hi Vijay, congrats to you!

      You have done all the modifications correctly, and everything seems perfect to me, a 1 second delay will not affect your autotransformer in any manner, because before getting damaged the transformer will first have to heat up, and when it reaches above 150 degrees only then it might start smoking and this might take more than 20 to 30 seconds.

      By the way what did you use for the opto coupler? is it a readymade LED/phototransistor opto or the recommended LED/LDR type homemade opto?….the LED/LDR would provide better and more reliable results compared to the conventional one.

      Reply
    • Vijay says

      May 13, 2015 at 6:33 am

      Hi Swagatam, Thanks. I used MCT2E. I was thinking of trying an LED/LDR combo if 100K between MCT2E and T1 base didn't do the trick but it did.

      Vijay

      Reply
    • Swagatam says

      May 13, 2015 at 9:34 am

      OK, that's fine Vijay, everything's well that ends well..

      Reply
  23. Vijay says

    April 23, 2015 at 6:59 am

    Yes, I used two .47E resistors in series as I couldn't get 1 ohm for a 3amp load. Anyway, I'll try again and update.

    Thanks,
    Vijay

    Reply
    • Swagatam says

      April 23, 2015 at 11:11 am

      OK! thanks

      Reply
  24. Vijay says

    April 22, 2015 at 5:40 pm

    Hi Swagatam,

    Just like your voltage stabilizer circuit using opamps, I have also tried this circuit (with an optocoupler) and it works. But it triggers quite often even when there is not so much load. Adjusting the preset does not help. Any ideas?

    Reply
    • Swagatam says

      April 23, 2015 at 6:26 am

      Hi Vijay,

      did you calculate R1 correctly? please calculate such that the opto led lights up only when there is a true overload as per the required specifications.

      alternatively you may also try adding a 1uF capacitor across base and ground of the T1

      Reply
  25. Precious Ubani says

    November 1, 2013 at 4:32 pm

    Thank you very much. I will build this circuit using an optocoupler and give you feedback.

    Reply
  26. Precious Ubani says

    October 29, 2013 at 4:42 pm

    Thank you for the answer on P1 but what is the value of R2. Is it 56 ohms?

    Reply
    • Swagatam says

      October 30, 2013 at 5:09 am

      yes 56 ohms, it's the LED current limiting resistor

      Reply
  27. Precious Ubani says

    October 27, 2013 at 12:17 pm

    please, what is the function of P1?

    Reply
    • Swagatam says

      October 28, 2013 at 2:55 pm

      For adjusting the sensitivity of the circuit….

      Reply
  28. Ajay says

    July 17, 2013 at 5:42 pm

    Hello Swagatam,

    Thanks very much for your kind and prompt response, need your advice to decide on the relay and T1, as I will be using a relay that can bear a minimum load of 15Amps, and have decide to build the the following:

    https://www.homemade-circuits.com/2011/12/simple-mains-high-and-low-voltage.html

    Regards,

    Ajay

    Reply
    • Swagatam says

      July 18, 2013 at 5:48 am

      Hello Ajay

      You may use the relay which is shown below:

      " rel="nofollow ugc">comment image

      OEN/12V/285ohms/16amp/SPDT

      Reply
  29. Ajay says

    July 16, 2013 at 7:26 pm

    Hello Swagatam,

    Thanks for the quick response, to be very precise I have recently bought a Hitachi AC model RAW318KTD, my previous AC compressor was blown due to the stabilizer was generating 300VAC. I have got the stabilizer repaired how ever want to be very cautious this time.

    My AC specs are Current drawn-4.7 amps, Rated power supply -(230/50/1 Volts/Hz/Phase), Total Power input-1055 Watts.

    Sorry for bothering you again.

    Regards,

    Ajay

    Reply
    • Swagatam says

      July 17, 2013 at 5:29 am

      Hello Ajay,

      You will need an over voltage protector circuit in that case. You can make the following circuit:

      https://www.homemade-circuits.com/2011/12/simple-mains-ac-over-voltage-and-under.html

      It will protect your AC from high voltages as well as low voltages.

      Reply
  30. Ajay says

    July 15, 2013 at 6:24 pm

    Hello Swagatam,

    I want to apply this CKT to my Air Condition stabilizer which is 3Kva can you help me decide on the relay rating and R1 my AC is 1400Watts.

    Regards,

    Ajay

    Reply
    • Swagatam says

      July 16, 2013 at 5:04 am

      Hello Ajay,

      Here are the details

      3000/220 = 13 amps

      Therefore R1 = 2v/13 = 0.15ohms 3watts

      Relay contacts must be rated at 20 amps

      Reply
    • Swagatam says

      July 16, 2013 at 5:07 am

      …for 1400 watts it would be

      1400/220 = 6.36amps

      R1 = 0.3 ohms/ 2 watts

      Relay contacts @10 to 12 amps.

      Reply
    • Rajeev Mehndiratta says

      September 20, 2016 at 7:40 am

      How you are calculating power of resistor R1? P=I2XR or P=VI ? Please explain.

      Reply
    • Swagatam says

      September 21, 2016 at 2:42 am

      P = VI….V = voltage drop across resistor

      Reply
      • Godson says

        August 31, 2017 at 1:09 pm

        Hello sir Swagatam. I really appreciate your effort. I’ve been looking for an overload protection for inverter circuit. You have so far referred me to two post but this one is just the perfect one for the intended purpose. I’ve read through the comments and have gotten more info from your responses. Thank you sir. I have a few questions:
        1. In your response above as regards how to calculate the sensing resistor wattage, you said that: P = VI, V = voltage drop across resistor. How do we determine this voltage?
        2. I want to design the circuit in such a way as to use it to power off the inverter when overload is sensed at the transfo output. So i want to use a smaller relay such that the contacts will be used to disconnect power to the inverter oscillator during overload condition. So what i want to do is to allow the output of the transfo to pass through the sensing resistor directly to the load. Can i go ahead with that arrangement?
        3. From the schematic, which side/pin of C2 is positive?

        Reply
        • Swagatam says

          August 31, 2017 at 2:08 pm

          Hello Godson, you can use the relay contact for the mentioned purpose, so in that case connect the indicated relay contact wire directly with the load.

          watt of the resistor will be = bridge drop + LED drop / shut down current
          = 1.2 + 1.5 / D current.
          the white side of c2 is the positive.

          Reply
          • Godson says

            August 31, 2017 at 4:55 pm

            Please pardon me sir, I still don’t fully understand the explanation you gave in your response to how to calculate the wattage of the sensing resistor. Please could use the example you gave above for a 3KVA inverter to explain, I’ll understand it better that way. Thank you sir.

            Reply
            • Swagatam says

              September 1, 2017 at 2:22 am

              Godson, the wattage will equal to the voltage drop across the resistor multiplied by the shut down current limit selected by you.

              the voltage drop across the resistor can be achieved by adding the bridge rectifier drop (approximately 1.2V) and the LED FWD voltage drop (approximately 2V)

              Reply

Need Help? Please Leave a Comment! We value your input—Kindly keep it relevant to the above topic! Cancel reply

Your email address will not be published. Required fields are marked *

Primary Sidebar

Subscribe to New Circuit Ideas

Categories

  • Arduino Projects (87)
  • Audio and Amplifier Projects (132)
  • Automation Projects (17)
  • Automobile Electronics (101)
  • Battery Charger Circuits (83)
  • Datasheets and Components (104)
  • Electronics Theory (143)
  • Free Energy (37)
  • Games and Sports Projects (11)
  • Grid and 3-Phase (19)
  • Health related Projects (25)
  • Home Electrical Circuits (12)
  • Indicator Circuits (14)
  • Inverter Circuits (87)
  • Lamps and Lights (142)
  • Meters and Testers (69)
  • Mini Projects (46)
  • Motor Controller (64)
  • Oscillator Circuits (27)
  • Pets and Pests (15)
  • Power Supply Circuits (108)
  • Remote Control Circuits (50)
  • Security and Alarm (64)
  • Sensors and Detectors (101)
  • Solar Controller Circuits (59)
  • Temperature Controllers (42)
  • Timer and Delay Relay (49)
  • Transmitter Circuits (29)
  • Voltage Control and Protection (37)
  • Water Controller (36)

Calculators

  • Battery Back up Time Calculator
  • Capacitance Reactance Calculator
  • IC 555 Astable Calculator
  • IC 555 Monostable Calculator
  • Inductance Calculator
  • LC Resonance Calculator
  • LM317, LM338, LM396 Calculator
  • Ohm’s Law Calculator
  • Phase Angle Phase Shift Calculator
  • Power Factor (PF) Calculator
  • Reactance Calculator
  • Transistor Astable Calculator
  • Transistor base Resistor Calculator
  • Voltage Divider Calculator
  • Wire Current Calculator
  • Zener Diode Calculator
  • Filter Capacitor Calculator
  • Buck Converter Calculator
  • Boost Converter Calculator
  • Solar Panel, Inverter, Battery Calculator
  • Wire Current Calculator
  • SMPS Transformer Calculator
  • IC SG3525, SG3524 Calculator
  • Inverter LC Filter Calculator

People Also Search

555 Circuits | 741 Circuits | LM324 Circuits | LM338 Circuits | 4017 Circuits | Ultrasonic Projects | SMPS Projects | Christmas Projects | MOSFETs | Radio Circuits | Laser Circuits | PIR Projects |

Recent Comments

  • Swagatam on Real MPPT Solar Charger Circuit Using Arduino, LCD, and Manual/Auto Switch
  • Obaidullah Khan on Real MPPT Solar Charger Circuit Using Arduino, LCD, and Manual/Auto Switch
  • Swagatam on 2 Compact 12V 2 Amp SMPS Circuit for LED Driver
  • Alan Bishop on AC Motor Speed Controller Circuits using Back EMF
  • Swagatam on Real MPPT Solar Charger Circuit Using Arduino, LCD, and Manual/Auto Switch

Company

  • Privacy Policy
  • Cookie Policy
  • About Me
  • Contact
  • Disclaimer
  • Copyright
  • Videos
  • Sitemap

Social Profiles

  • Twitter
  • YouTube
  • Instagram
  • Pinterest
  • My Facebook-Page
  • Quora
  • Stack Exchange
  • Linkedin