Refrigerator Motor Soft Start Circuit

Last Updated on January 6, 2020 by Swagatam 26 Comments

Refrigerators tend to draw appreciable amounts of current each time their compressor switch ON, and this could happen many times per day. A soft start circuit to the compressor motor could probably tackle this issue and help save electricity. The idea was requested by Mr. Naeem Khan.

Table of Contents
  • Technical Specifications
  • The Design
  • How the Circuit Operates
  • Circuit Diagram

Technical Specifications

I need your help regarding to control the starting torque(soft start) of the Refrigerator Compressor for energy saving purpose. All these compressor are capacitor start type. If you have any other idea to control these capacitor start compressor RPM then let me know.
Awaiting your reply soon.

The Design

The capacitor in a capacitor start motor has nothing to do with the speed of the motor. The capacitor is there just to energize the field coil of the motor for helping the main winding to start the rotation, after which it's cut-of from the system.

In any case, the soft start circuit presented here is irrelevant to the type of AC motor used, it should hopefully work for all types of motor.

Referring to the figure we see an arrangement where the refrigerator is wired in  series with a rectifier diode which has an SCR connected in parallel.

The operation is rather simple.

How the Circuit Operates

As soon as the internal relay of the refrigerator clicks ON, diode D1 provides a half wave AC to the refrigerator forcing a slow soft start to the motor, the SCR is unable to conduct immediately due to the the presence of the capacitor at its gate.

Therefore at the start, the refrigerator is able to get only a half wave AC through the rectifier diode, until the capacitor across the SCR gate/cathode charges up and fires the SCR.

During this period the half wave AC allows only around 50% of initial voltage to the refrigerator, providing a soft start to the motor, until within seconds the SCRs fires and restores full available power to the motor.

Once the SCR is fired it takes on the other half of the AC so that the refrigerator motor is able to gain its full rated torque.

Circuit Diagram

refrigerator soft start circuit 1

Parts List

R1 = 47K 1watt

D1 = 6 amp diode

D2 = 1N4007

Z1 = 50V 1 watt zener

C1 = 10uF/400V

Switch ON Starting Power Calculation 

Since initially the series diode converts the AC input into a half wave DC, it's important to know the average DC applied at the particular instant. It may be calculated using the formula:

Vdc av = Vp/π

where π = 3.1416, and Vp = peak half wave value

The π value may be solved and the above formula may be further expressed as:

Vdc av = 0.318 Vp

The peak voltage may be calculated by using the following formula:

peak volts = RMS volts x 1.414

therefore we get:

Vp = Vrms x 1.414

For a 220V RMS, the above formula could be solved as:

Vp = 220 x 1.414 = 311.08V

For accuracy we can also include the 0.7V drop produced by the diode in our calculation:

Vdc av = (VP - 0.7)/π

Solving the above equation with Vp = 311.08, we get:

Vdc av = (311.08 - 0.7)/π = 98.84V

If the refrigerator motor coil resistance is known the above DC average voltage could be used for calculating the initial soft-start power consumed by the motor, through the following formula:

P = I2R, where P stands for power,

I = current (amps) and R = resistance of the motor coil

I (amps) could be found by applying Ohms law:

IDC  = VDC /R,

where R = resistance of the motor coil, and VDC = 98.84V obtained from the previous calculations. where π = 3.1416.

Warning: The circuit has not been tested or verified practically, and the effects are unknown. Initially try the circuit by using a 200watt bulb. The bulb should brighten up slowly in comparison to when it's connected directly to mains.

Also the entire circuit is directly linked with mains and is therefore extremely dangerous while plugged in and without an enclosure.

You'll also like:

  • 1.  How to Make a PWM Controlled Fan Regulator Circuit
  • 2.  Water/Coffee Dispenser Motor Circuit
  • 3.  PWM Motor Soft Start Circuit to Prevent High Consumption during Power Switch ON
  • 4.  3 Phase Induction Motor Speed Controller Circuit
  • 5.  Understanding Scalar (V/f) Control for Induction Motors
  • 6.  Stepper Motor Driver Circuit using IC 555

About Swagatam

I am an electronics engineer with over 15 years of hands-on experience. I am passionate about inventing, designing electronic circuits and PCBs, and helping hobbyists bring their projects to life. That is why I founded homemade-circuits.com, a website where I share innovative circuit ideas and tutorials. Have a circuit related question? Leave a comment.... I guarantee a reply!

Previous Post: « How to Make a PWM Controlled Fan Regulator Circuit
Next Post: How to Make Adjustable Current Limiter Circuits »

Reader Interactions

Comments

  1. Ramsey says

    June 21, 2021 at 6:17 pm

    Most of the refrigerators I have seen so far have an integrated motor – compressor. Yes, they are capacitive start but the motor is basically a vibrator and it works like a fish tank air bubbler (diaphram valve type). The compressor (about 100W or often less) draws high current because the capacitors need to be charged up and that takes only a few milliseconds. Adding a series inductor can help the inverter not to trip.

    Reply
    • Swagatam says

      June 21, 2021 at 9:16 pm

      Thank you for the valuable feedback!

      Reply
  2. Johannes Blomerus says

    March 4, 2021 at 7:13 pm

    Hi, In your SCVR soft start circuit diagram I note under “SCR1” there is another diode (just before the Zener). Is my observation correct that there is a second diode and if so would it be the same value as D1? Regards

    Reply
    • Swagatam says

      March 5, 2021 at 11:01 am

      Hi, there are two diodes D1 and D2, whose values are given in the parts list!

      Reply
  3. Jerard says

    August 4, 2020 at 10:41 am

    Superb sir, I’ll try this to reduce the starting current of my fridge sir. Regards

    Reply
    • Swagatam says

      August 4, 2020 at 2:20 pm

      Thanks Jerard, please note that the concept is not yet tested and confirmed practically

      Reply
  4. Mike LaVigne says

    January 6, 2020 at 9:52 am

    I would not be so quick to try this out without first doing it with a motor not connected to a Freon compressor. The reason being that these compressors must come up to speed within just a few tenths of a second. I installed a unit made by Emerson for their Copeland scroll compressor called SecureStart Part# 943-0120-00 on my 5T heat pump. It limits the inrush current to that of the LRA spec I think 7A. The sweet part is that it spins up the motor in the prescribed time to prevent damage to the equipment. They aren’t cheap but I can start my heat pump on my 10KW generator.

    Reply
  5. Dayo says

    July 20, 2018 at 8:03 pm

    Hello, I tested the circuit, but never did soft start for my freezer, any other advice. I also tried the circuit on triac controlling inductive loads, same thing. Thanks

    Reply
    • Swagatam says

      July 20, 2018 at 8:54 pm

      OK so what is the fault in the above design please tell us?

      Reply
      • Kassie Kasselman says

        January 17, 2019 at 8:08 pm

        The fridge compressor motor has two windings, a start and run winding. They connect the start winding through a capacitor to AC (through the temperature control switch). The run winding connects to AC as well.
        So your circuit is simply in-between the temperature controller and the compressor? Affecting both windings?

        Reply
        • Swagatam says

          January 17, 2019 at 9:06 pm

          Yes I know the refrigerator compressor is a capacitor start motor. The circuit is only to prevent a sudden full voltage to the motor, rather a two step rising voltage within a span of may be milliseconds, but whether this is harmful or not to the motor only a motor expert can say!

          Reply
          • Kassie Kasselman says

            January 17, 2019 at 9:37 pm

            Thank you for the quick response. I will test it and let you know what I find.

            Reply
    • Dayo says

      July 20, 2018 at 11:51 pm

      I don’t know the fault, but the current draw was even too high. Can you please help us test it to perfect the design. Thanks

      Reply
      • Swagatam says

        July 21, 2018 at 7:51 am

        the refrigerator is in series with the mains so whatever current draw you are seeing it is by your refrigerator only.

        As you can see there’s hardly any component in the design and I have explained its working clearly which can be easily understood by anybody.

        If you are having difficulty understanding it You can put this link to any electronic forum and ask their response about this and see if you can get an appropriate reply.

        Reply
  6. Phil says

    January 17, 2018 at 5:07 am

    Hi, I have a boiler pump that would be better if it soft started so in a power failure so my inverter would not have to put a temporary surge off the battery I use. I am not sure this circuit will work, no one has built it yet and tested for me ? Some circuits use a triac do you have one that will work like the above circuit? Also, how do you test the breakdown voltage of a zener diode, I have a lot of them that are unmarked. Thank you

    Reply
    • Swagatam says

      January 17, 2018 at 9:30 am

      Hi, you could probably try the second circuit from the following post, it is not a tested one but it has to work, because the design concept looks very obvious and it cannot fail

      https://www.homemade-circuits.com/adding-soft-start-to-water-pump-motors/

      for identifying the zener voltage you can connect the respective zener across a DC voltage source through a 10K resistor, and measure the potential right across the zener diode pins, this will give you the required data regarding the device.

      Reply
  7. Hamid s k says

    October 16, 2016 at 6:05 am

    hi Swagatam , and thanks for sharing such elegant idea , I was wondering if received any feedback from any user that used your idea? actually I'm Arduino fan and control the home appliance is one of my biggest fun , I read couple of inverter open source to have full control over the AC motors , but my Idea have change due to it may not economical , then I decided to follow the way which control the motor in 2 or 3 different speed and not 0 to 100 % full control anymore , also your elegant way to soft starting motor is quite fascinating for me to implement it , I hope have your advise to start such practical project
    best regards

    Reply
  8. Bernard Tendengu says

    January 7, 2016 at 10:55 am

    Dear Swagatam,

    In the motor soft start circuit for the refrigerator, you did not specify the type of the thyristor to be used. Are we free to use any type of thyristor.

    Regards

    Bernard Tendengu

    Reply
    • Swagatam says

      January 7, 2016 at 1:07 pm

      Dear Bernard, you can try using a BT151.

      Reply
  9. Sadananda Naik says

    June 21, 2014 at 6:21 am

    Hi,
    Another doubt, when we use a diode in series with a load, it gets half of the supply voltage. So the power consumption reduces to 1/4 ie. 25% not 50%, if voltage reduces to 1/3, the power reduces to 1/9 so

    Reply
    • Swagatam says

      June 21, 2014 at 10:02 am

      I have only tried to present a general concept quickly, the critical aspects and conditions will need to be calculated, confirmed by the user while making the practical design.

      Reply
    • Swagatam says

      June 21, 2014 at 12:23 pm

      I have added the required info for your reference….

      Reply
  10. Sadananda Naik says

    June 21, 2014 at 6:15 am

    Hi,
    Have you tested this circuit? I think capacitor start induction run motor is used in the compressors, (if you use a lamp, it will glow) such motors do start or run in half or full wave DC ( only universal motors, used in mixie, power tools etc; can start/ run in AC as well as DC

    Reply
    • Swagatam says

      June 21, 2014 at 9:58 am

      Hi,

      Please read the warning message at the bottom, I have clearly mentioned my doubts there.

      I have given the example of a bulb just to make sure nothing goes in smoke while using it with any other form of load.

      Reply
  11. Abu-Hafss says

    June 15, 2014 at 3:34 pm

    Hi Swagatam

    Would you please provide the specs of the SCR?

    Reply
    • Swagatam says

      June 16, 2014 at 4:44 am

      Hi Abu-Hafss,

      We can try BT151, I think it would work for the above application, its RMS current handling capacity is only 4 amps but since the initial surge is sinked by the diode, the scr would stay aloof from it.

      Reply

Need Help? Please Leave a Comment! We value your input—Kindly keep it relevant to the above topic! Cancel reply

Your email address will not be published. Required fields are marked *

Primary Sidebar

Subscribe to New Circuit Ideas

Categories

  • Arduino Projects (87)
  • Audio and Amplifier Projects (132)
  • Automation Projects (17)
  • Automobile Electronics (101)
  • Battery Charger Circuits (83)
  • Datasheets and Components (104)
  • Electronics Theory (143)
  • Free Energy (37)
  • Games and Sports Projects (11)
  • Grid and 3-Phase (19)
  • Health related Projects (25)
  • Home Electrical Circuits (12)
  • Indicator Circuits (14)
  • Inverter Circuits (87)
  • Lamps and Lights (142)
  • Meters and Testers (69)
  • Mini Projects (46)
  • Motor Controller (64)
  • Oscillator Circuits (27)
  • Pets and Pests (15)
  • Power Supply Circuits (108)
  • Remote Control Circuits (50)
  • Security and Alarm (64)
  • Sensors and Detectors (101)
  • Solar Controller Circuits (59)
  • Temperature Controllers (42)
  • Timer and Delay Relay (49)
  • Transmitter Circuits (29)
  • Voltage Control and Protection (37)
  • Water Controller (36)

Calculators

  • Battery Back up Time Calculator
  • Capacitance Reactance Calculator
  • IC 555 Astable Calculator
  • IC 555 Monostable Calculator
  • Inductance Calculator
  • LC Resonance Calculator
  • LM317, LM338, LM396 Calculator
  • Ohm’s Law Calculator
  • Phase Angle Phase Shift Calculator
  • Power Factor (PF) Calculator
  • Reactance Calculator
  • Transistor Astable Calculator
  • Transistor base Resistor Calculator
  • Voltage Divider Calculator
  • Wire Current Calculator
  • Zener Diode Calculator
  • Filter Capacitor Calculator
  • Buck Converter Calculator
  • Boost Converter Calculator
  • Solar Panel, Inverter, Battery Calculator
  • Wire Current Calculator
  • SMPS Transformer Calculator
  • IC SG3525, SG3524 Calculator
  • Inverter LC Filter Calculator

People Also Search

555 Circuits | 741 Circuits | LM324 Circuits | LM338 Circuits | 4017 Circuits | Ultrasonic Projects | SMPS Projects | Christmas Projects | MOSFETs | Radio Circuits | Laser Circuits | PIR Projects |

Recent Comments

  • Swagatam on How to Make Dog Barking Preventer Circuit using High Frequency Deterrence
  • Swagatam on How to Buy and Use RF Remote Control Modules – Control Any Electrical Gadget Remotely
  • Swagatam on How to Generate PWM Using IC 555 (2 Methods Explored)
  • Swagatam on Understanding SG3525 IC Pinouts
  • Dan on Understanding SG3525 IC Pinouts

Company

  • Privacy Policy
  • Cookie Policy
  • About Me
  • Contact
  • Disclaimer
  • Copyright
  • Videos
  • Sitemap

Social Profiles

  • Twitter
  • YouTube
  • Instagram
  • Pinterest
  • My Facebook-Page
  • Quora
  • Stack Exchange
  • Linkedin
  • © 2025 · Swagatam Innovations