There are three ways to interconnect resistors: series, parallel and in combination of series/parallel. When resistors are joined in series, the current passing via one resistor also passes through the next. When resistors are joined in parallel, they are wired across each other, resulting in the same voltage across each resistor. When resistors are connected in a combination of series and parallel, the current passage is a bit more complex.

Table of Contents
  • Connecting Resistors in Series:
  • Connecting Resistors in Parallel:
  • Combination of Series and Parallel:

Connecting Resistors in Series:

resistors in series

Assume you have three resistors with resistances of 10, 20, and 30 ohms. For a series connection:

We connect the 3 resistors one after the other as shown in the above figure.

The total series resistance can be measure across the ends of the series connection using a Ohm meter or can be calculated as I have explained below.

According to Ohm's law the total resistance of the series resistors can be calculated simply by adding the three resistor values.

R(total) = 10 + 20 + 30 = 60 ohms is the total resistance of the circuit.

Connecting Resistors in Parallel:

resistors in parallel

Let's say you have three resistors with values of 10 ohms, 20 ohms, and 30 ohms. In order to connect them in parallel, you will need to follow the below shown steps:

Connect all left side ends together, and then connect all the right side ends together, as shown in the above figure.

You can measure the parallel resistance value using an Ohm meter by connecting the ends of the resistances with the meter probe.

Alternatively, using the standard formula, the total resistance of the parallel circuit could be calculated as the reciprocal of the sum of the reciprocals of the individual resistances:

1/Rp(total) = 1/10 + 1/20 + 1/30 = 5.45 ohms.

Combination of Series and Parallel:

combining resistors in series and parallel

Now, let's assume we have four resistors with values of 10 ohms, 20 ohms, 30 ohms, and 40 ohms. To connect them in a combination of series and parallel we do the following setup

First we connect 3 resistors in parallel, meaning we connect the 10 ohm, 20 ohm and 30 ohm in parallel.

Then we connect a 40 ohm and a 20 ohm resistor in series and join this series connection with the above parallel setup.

To solve this series, parallel combination, we first solve the parallel configuration using the following formula:

1/Rp(total) = 1/10 + 1/20 + 1/30

R(total) = 5.45 ohms

Once the parallel combination is solved, then we solve the series combination using the following formula:

Rs(total) = 20 + 40 = 60 ohms.

Now, looking at the diagram it is obvious that the 5.45 ohms value of the parallel resistors is in series with the above 60 ohm resistor.

Therefore, we now simply add the 5.45 ohm with the 60 ohm to get the final result of the series, parallel combination, in the following manner:

R(total) = 5.45 + 60 = 65.45 Ohms

If you connect an ohm meter probes to the parallel end and the series end of the above combination, you will get the same value as obtained from the above calculation.

You'll also like:

  • 1.  Calculating Transistor as a Switch
  • 2.  DC Biasing in Transistors – BJTs
  • 3.  What is beta (β) in BJTs
  • 4.  How to Troubleshoot Transistor (BJT) Circuits Correctly
  • 5.  How an Accelerometer Works
  • 6.  How to Select MOV – Explained with a Practical Design

About Swagatam

I am an electronics engineer with over 15 years of hands-on experience. I am passionate about inventing, designing electronic circuits and PCBs, and helping hobbyists bring their projects to life. That is why I founded homemade-circuits.com, a website where I share innovative circuit ideas and tutorials. Have a circuit related question? Leave a comment.... I guarantee a reply!

Previous Post: « TIP122 Datasheet [100V, 5 amp, NPN, Darlington Transistor]
Next Post: IC 4013 Datasheet, Pinout Details »

Reader Interactions

Comments

  1. suat kaleli says

    February 8, 2025 at 3:11 pm

    Hi Dear Swagatam;
    Ref. to the short circuit tests they are used to connecting a serial bulb to the circuits. I watch the tv repair videos by master Tevz on the Youtube and he uses the resistor in place of the fuse and instead of a serial bulb while intial test of the repaired tv. If we assume that the tv is 220V and 160W so then which value of the resistor (both ohm and watt) we should prefer could you please tell me about that?

    Reply
    • Swagatam says

      February 8, 2025 at 7:15 pm

      Hi Suat,
      A series bulb is the right way to test the short circuit condition of any circuit, because the bulb will light up and become a high value resistor only when a short circuit current is detected, so the brightness of the bulb will directly indicate the condition of the circuit output. A resistor cannot provide this facility, so a resistor is not an appropriate option for such applications.

      However we have to select a bulb whose power rating is lower than the power rating handling capacity of the circuit output device.

      Reply
      • suat kaleli says

        February 20, 2025 at 3:03 pm

        Thanks Swagatam for the kind responce. There was no gate voltage from the driver ic then I shorted the mosfet drain and source for led TV lights 
        (There are 91 leds and about 230V) I also used a serial bulb for safety checking.
         The bulb is not OFF or not ON but it blinks. Could you please tell what that means?  

        Reply
        • Swagatam says

          February 20, 2025 at 6:17 pm

          Hi Suat,
          Is the bulb blinking after shorting the MOSFET D/S, or without shorting it.

          Reply
          • suat kaleli says

            February 20, 2025 at 6:37 pm

            at the initial test at first I had shorted the 5V and stdby pins and the bulb lighted very short and then it was OFF but as soon as I shorted the mosfet drain with the gnd then the bulb was blinking. However after sending the message I retested and this time it blinks even the mosfet drain is not short with the gnd.

            Reply
            • Swagatam says

              February 20, 2025 at 6:51 pm

              The bulb is supposed to light up constantly once the MOSFET is shorted because the MOSFET is main switching element which handles the full power.
              If the bulb is blinking even while the MOSFET is shorted (disabled) then it is so confusing, because now the question is then which part is controlling the lamp blinking or the lamp power?
              Not sure until we see the full schematic diagram.

              Reply
  2. suat says

    November 23, 2024 at 1:47 pm

    Hi Swagatam;
    After the below messages I used the 110AC appliance (air fryer) and 170uF capacitor and a 5 Ohm NTC in serial connected under the 220AC applied voltage as you had advised. After the test I see that the opening screen (start/stop button light) and warning signals(a few beeps sound) are OK. And I measure about 120V DC over the capacitor. However whenever I push the start button, I see the screen for a while (about 5 seconds) and then the screen disappears and I see about 260V over the capacitor. Would you please do a comment on the matter?

    Reply
    • Swagatam says

      November 23, 2024 at 2:09 pm

      Hi Suat,
      It seems there’s some internal smart cut-off circuitry which is detecting the momentary high voltage input and disconnecting the supply to the air fryer…that means this idea might not work for your device.

      Reply
      • suat says

        November 23, 2024 at 2:34 pm

        Thanks Swagatam and I am sorry after sending the message I have seen (at the youtube) that the value of the current capacity of the NTC 5D-11 is for 4A on which I had tought that it was 11A. So I am going to try to test it one more time with the 10A NTC. And if it has no higher risk I may try it for a very short period without the NTC.

        Reply
        • Swagatam says

          November 23, 2024 at 5:06 pm

          No problem Suat! If you use a 150uF/400V cap then you can check it without an NTC, because 150uF will restrict the current to 7 amps.
          But still you can try with a 10 amp NTC and check the results…

          Reply
  3. suat says

    November 10, 2024 at 3:49 pm

    Hi Mr. Swagatam;
    I have the heater resistor (as a part of the airfryer) and it’s specs.: 120V AC 1000W (8,5A) and about 14,5 Ohm. I need to use this resistor with the 220V AC. And if I have not made a mistake I should use 400V 0,002 mF(2000pF) serial capacitor to run it. (As per your advice we had used 4 mF serial capacitor for the 120V fan motor) but this time the current ratio is too high. So I need your advice / opinion please?

    Reply
    • Swagatam says

      November 10, 2024 at 4:27 pm

      Hi Suat,
      As a rule of thumb, a 1uF/400V capacitor allows around 50 ma current, so 8.5/0.05 = 170uF
      So to limit the current to 8.5 amps, the capacitor value should be around 170uF/400V non-polar.

      Reply
      • suat says

        November 10, 2024 at 7:47 pm

        Thanks Swagatam, so it seems to buy 220V 1000W new heater resistance is more reasonable. Have nice weekend

        Reply
        • Swagatam says

          November 11, 2024 at 8:39 am

          No problem Suat, yes, buying a new 220V heater coil looks more affordable…

          Reply
          • suat says

            November 11, 2024 at 2:01 pm

            Sorry Swagatam this question may be unpredictable before the practise but instead of modifying / changing the parts one by one, is it possible to apply 220V AC directly to the input of the equipment by using the 170uF capacitor in serial? If it is tolerable so then it may be affordable. P.S.: The Airfryer itself is 120V 1000W too.

            Reply
            • Swagatam says

              November 11, 2024 at 2:53 pm

              Hi Suat,
              According to me, yes, you can connect the 220V to the load through the series 170uF capacitor, without anything else in the middle.
              Just make sure the capacitor is non-polar, and preferably first try with a 150uF.

              Reply
              • suat says

                November 15, 2024 at 9:36 am

                Swagatam as you advised I have tried the circuit by using 145uF (50+50+45 three capacitors parallel connected) and used 2A Fuse for the safety measurement. I have not used any termistor (10A hard to find at the market) or varistor . The result was very rejoicing and successful. Now I will remove the 2A fuse and replace 10A fuse. I am ready to test it with the 170uF capacitor and to test it’s 8A heating element. Accordingly I remain for your final advices if there is. with my special thanks and gratefulness

                Reply
                • Swagatam says

                  November 15, 2024 at 10:55 am

                  That’s great Suat, glad it is working for you.
                  But the NTC is very important and you must consider using it, you can use a 20 amp NTC instead, or use two 10 ohm/5amp NTCs in parallel.

                  Reply
                  • suat says

                    November 21, 2024 at 1:34 pm

                    Sorry Swagatam but I am not able to comprehend the matter on the
                    NTC current value? You have advised 2 different current value as the 10A(2* 5A as parallel connected) and 20A at your above message.
                    However my appliance power consumption is about 10A. Could you please confirm on if 20A is also can be OK for the 10A appliance?

                    Reply
                    • Swagatam says

                      November 21, 2024 at 2:58 pm

                      Hi Suat,
                      Your appliance is rated at 8.5 amps, so a 10 amp NTC should be Ok, but if you cannot get 10 amp NTC, then you can also use a 20 amp NTC.

  4. suat says

    November 26, 2023 at 1:02 am

    Hi Mr Swagatam;
    In case we have two cables and their thickness and the length are equal but one is stranded type and other is single core. then which one is more resistant against the heat?

    Reply
    • Swagatam says

      November 26, 2023 at 8:47 am

      Hi Suat,
      The standard cable which has multi-strand wire will generate less heat compared to a single core wire, so the multi-strand wire will be more efficient.

      Reply
  5. suat kaleli says

    May 2, 2023 at 7:49 pm

    Hi Swagatam;

    Let’s say we have 2 resistors of 100 Ohm and their wattage value are of 1/4 watts. When we connect them in parallel so then they would be as single resistor like with the value of 50 ohm however their wattage would be remain same as 1/4 watts or double as 1/2 watts?

    Best Wishes

    Reply
    • Swagatam says

      May 3, 2023 at 9:02 am

      Hi Suat,
      The wattage would become double, 1/2 watts.

      Reply
      • suat kaleli says

        May 3, 2023 at 1:18 pm

        thanks swagatam. We have the ordinary potentiometer at the market and i think they are called also universal hub single variable resistor. Neverthless it is not being mentioned about their wattage. For instant i have got 5K pot so please advise their wattage and if it is possible to connect them in parallel?

        Best Wishes

        Reply
        • Swagatam says

          May 3, 2023 at 2:04 pm

          Hi Suat, the ordinary pots are rated not more than 1/2 watt.
          If you want to add them in parallel then you will have to make sure they are GANGED, meaning their wiper knobs are tied with each other so that they rotate exactly in a synchronized manner.

          Reply
  6. suat kaleli says

    April 24, 2023 at 12:56 pm

    Hi Swagatam;

    I have been seeing the videos about making your own resistor. As known sometimes hard to find cement resistor at lower ohm value like 0,1 ohm and sometimes they are very expensive. It is possible to make them at home by defining its ohm value and wattage and which material is more poductive i.e. copper graphite (pencil core) or chrome wire?

    Best Wishes.

    Reply
    • Swagatam says

      April 24, 2023 at 8:12 pm

      Hi Suat,

      Sorry, I have no idea about this concept so not sure about it. I will have to investigate about it.

      Reply
  7. Carlos says

    March 23, 2023 at 9:24 pm

    hello, good afternoon. I have a question, I have to feed a 12 vdc relay from a 31 vdc voltage. Now the question is, can I put a resistive divider instead of using a regulator for example lm7812… Thank you very much in advance.

    Reply
    • Swagatam says

      March 24, 2023 at 9:10 am

      A resistive divider might drop too much current which might not be sufficient for the relay to operate. You will have to use a 7812 IC or step down buck converter.

      Reply

Need Help? Please Leave a Comment! We value your input—Kindly keep it relevant to the above topic! Cancel reply

Your email address will not be published. Required fields are marked *

Primary Sidebar

Subscribe to New Circuit Ideas

Categories

  • Arduino Projects (87)
  • Audio and Amplifier Projects (132)
  • Automation Projects (17)
  • Automobile Electronics (101)
  • Battery Charger Circuits (82)
  • Datasheets and Components (103)
  • Electronics Theory (143)
  • Free Energy (37)
  • Games and Sports Projects (11)
  • Grid and 3-Phase (19)
  • Health related Projects (25)
  • Home Electrical Circuits (12)
  • Indicator Circuits (14)
  • Inverter Circuits (87)
  • Lamps and Lights (142)
  • Meters and Testers (69)
  • Mini Projects (46)
  • Motor Controller (64)
  • Oscillator Circuits (27)
  • Pets and Pests (15)
  • Power Supply Circuits (108)
  • Remote Control Circuits (50)
  • Security and Alarm (64)
  • Sensors and Detectors (101)
  • Solar Controller Circuits (59)
  • Temperature Controllers (42)
  • Timer and Delay Relay (49)
  • Transmitter Circuits (29)
  • Voltage Control and Protection (37)
  • Water Controller (36)

Calculators

  • Battery Back up Time Calculator
  • Capacitance Reactance Calculator
  • IC 555 Astable Calculator
  • IC 555 Monostable Calculator
  • Inductance Calculator
  • LC Resonance Calculator
  • LM317, LM338, LM396 Calculator
  • Ohm’s Law Calculator
  • Phase Angle Phase Shift Calculator
  • Power Factor (PF) Calculator
  • Reactance Calculator
  • Transistor Astable Calculator
  • Transistor base Resistor Calculator
  • Voltage Divider Calculator
  • Wire Current Calculator
  • Zener Diode Calculator
  • Filter Capacitor Calculator
  • Buck Converter Calculator
  • Boost Converter Calculator
  • Solar Panel, Inverter, Battery Calculator
  • Wire Current Calculator
  • SMPS Transformer Calculator
  • IC SG3525, SG3524 Calculator
  • Inverter LC Filter Calculator

People Also Search

555 Circuits | 741 Circuits | LM324 Circuits | LM338 Circuits | 4017 Circuits | Ultrasonic Projects | SMPS Projects | Christmas Projects | MOSFETs | Radio Circuits | Laser Circuits | PIR Projects |

Recent Comments

  • Swagatam on Best Electronic Circuit Projects
  • TOMMY on Best Electronic Circuit Projects
  • Swagatam on Inverter Circuit with Feedback Control
  • Jerry Adeosun on Inverter Circuit with Feedback Control
  • Swagatam on Contact

Company

  • Privacy Policy
  • Cookie Policy
  • About Me
  • Contact
  • Disclaimer
  • Copyright
  • Videos
  • Sitemap

Social Profiles

  • Twitter
  • YouTube
  • Instagram
  • Pinterest
  • My Facebook-Page
  • Quora
  • Stack Exchange
  • Linkedin
  • © 2025 · Swagatam Innovations