No Load Detector and Cut-off Circuit for Inverters

Last Updated on August 3, 2020 by Swagatam 84 Comments

In this post I have explained a relay cut-off circuit which may be included in inverters to ensures that under a no load at the output the condition is quickly detected and the supply cut off, preventing the inverter from operating unnecessarily. The idea was requested by Mr. Rajath.

Technical Specifications

I need to adopt a no load auto cutoff system into my inverter, do you have any suitable design, which could help me. or else can you give any idea on how to achieve ,as i need to shut down the output of the inverter when ever there is no current drawn from it. please help me ,here.

Regards Rajath

The Design

In a few of ay previous posts we have learned how to make overload cut off circuit such as:

Low Battery Cut-off and Overload Protection Circuit.

Motor over current protector circuit

However, the present concept deals with an opposite situation wherein a no load condition is supposed to be detected and cut off for persisting, that is I have explained a circuit for preventing a no load condition for inverters.

As shown in the above figure, a no load detector and cut of procedure can be initiated by incorporating this design in any inverter circuit.

The operational details may be understood with the following explanation:

The circuit comprises two stage, namely the current amplifier and sensor stage using the T3/T4 Darlington pair, and a simple delay ON stage using T1, T2 and the associated components.

As soon SW1 is switched ON, the delay-ON timer counting is initiated through C1 which begins charging via R2 and D5 keeping T1 switched off in the process. With T1 switched T2 is switched ON which in turn switches ON the relay.

The relay enables the positive from the battery to get connected with the inverter so that the inverter is able to start and generate the required AC mains to the intended appliances.

With the presence of a load at the output the battery undergoes a proportionate amount current consumption, and in the course Rx experiences a current flow through it.

This current is transformed into a proportionate amount of voltage across Rx which is sensed by the T3/T4 Darlington pair and it is forced to switch ON.

With T3/T4 switched ON, C1 is instantly inhibited from getting charged, which leads to an immediate disabling of the delay ON timer, making sure that the output of the inverter continues to supply the voltage to the load.

However, suppose the output of the inverter is devoid of any load (no load condition), T3/T4 is then unable to switch ON, which allows C1 to get charged gradually until the potential across it becomes sufficient to trigger T1.

Once T1 is triggered, T2 is cut off and so is the relay. With the relay contacts cut off and shifted from N/O to the N/C contact, the positive to the inverter is also cut off, the system comes to a stand still.

You'll also like:

  • driverArduino 3 Phase Inverter Circuit with Code
  • TTP223 touch pad side compressedHow to Use TTP223 Capacitive Touch Switch Module [Pinouts Explained]
  • ELF monitor circuitExtremely Low Frequency (ELF) Radiation Monitor Circuit
  • 250 watt sine wave inverter compressed250 Watt Pure Sine Wave Inverter Circuit

Filed Under: Inverter Circuits, Sensors and Detectors Tagged With: Detector, Inverters, Load

About Swagatam

I am an electronics engineer and doing practical hands-on work from more than 15 years now. Building real circuits, testing them and also making PCB layouts by myself. I really love doing all these things like inventing something new, designing electronics and also helping other people like hobby guys who want to make their own cool circuits at home.

And that is the main reason why I started this website homemade-circuits.com, to share different types of circuit ideas..

If you are having any kind of doubt or question related to circuits then just write down your question in the comment box below, I am like always checking, so I guarantee I will reply you for sure!

Previous Post: « Simple Pneumatic Timer Circuit
Next Post: How to Make a Classroom Debate Timer Circuit »

Reader Interactions

Comments

Jason says:
July 1, 2025 at 8:52 am

I have a charger which has a current cutoff that is too low, and doesnt have a pot inside to adjust it higher.

Could this be adapted for that?

Could RX be replaced with a potentiometer?

Would a relay be too electrically noisy and interfere with the BMS and/or charger?

Charging load = >84v 10.5A max

Thanks

Reply
Swagatam says:
July 1, 2025 at 9:42 am

Yes, that’s possible, but the variable current configuration must be done through a parallel preset, as shown in the following figure. The relay operation will not be noisy, if you put a snubber network around its contacts, and also put a 100uF capacitor parallel to the coil of the relay:
https://www.homemade-circuits.com/wp-content/uploads/2025/07/current-sensing-adjustable.jpg

Reply
Jason says:
July 2, 2025 at 5:14 am

How does the 1k pot affect the equation for Rx and wattage?

Will it give me a .2 – 1A range?

Obviously the relay will have to be uprated for +84V but what about the other components? ie BC547 max voltage is 45V

Could the turn on phase confuse the CC/CV charger?

Reply
Swagatam says:
July 2, 2025 at 8:45 am

The Rx wattage has no relation to the 1k preset.
for 1A current, Rx = 0.2/1 = 0.2 Ohms
wattage = 0.2 watts.
For the relay you can use a 12V relay with a buck converter regulator such as the one explained in the following article.
I have no idea about your last question.
https://www.homemade-circuits.com/adjustable-1-2v-to100v-dc-buck-converter-circuit-using-lm5164/

Reply
yusuf says:
February 10, 2022 at 4:40 pm

if the load current is say 10am,what will be the wire gauge from the base of t3/t4 and the +terminals of the base? I am really confuse sir

Reply
Swagatam says:
February 10, 2022 at 5:02 pm

wire gauge is not important for T3/T4 base….it can be any thin wire.

Reply
Amos Nyeneime Dominic says:
November 17, 2021 at 2:40 am

Please can you assist me with 24volt 2kva inverter circuit with full protection?

Reply
Swagatam says:
November 17, 2021 at 4:20 pm

you can try the first diagram from the following article:

https://www.homemade-circuits.com/inverter-circuit-with-feedback-control/

First try this basic diagram, if you succeed then you can upgrade this to 2kva

Reply
Mahasetra says:
September 5, 2020 at 11:30 am

Hello, thank you for your diagram, it is very enriching. I would like to use it to automatically turn off a solar inverter when not in use (no load). Do I have to choose a high-current relay if I plan to draw about 100A from the battery when the inverter is on? Thank you in advance

Reply
Swagatam says:
September 6, 2020 at 11:28 am

Thank you, yes the relay contact current rating should be ideally two times more than the intended maximum load current

Reply
sir says:
June 28, 2020 at 9:24 pm

hello sir
i try this circuit but when i disceonect the load and connect it again the relay dosnt switsh on

Reply
Swagatam says:
June 29, 2020 at 10:32 am

The load should be high enough to create at least 1 V across Rx and enable T3/T4 conduction. If this does not happen, the relay will not activate

Reply
sir says:
July 7, 2020 at 5:33 pm

Hello Sir
-The battery is a12V 8Ah lithium ion
-The inverter is 12 TO 220V based on transistor astable 60Hz circuit with 2 irf640 mosfet connected to 300 watt center tape toroidal transformer
-The minimum load is 220V 9W bulbs consuming 0.340 A
-The system consume 0.16A with no load connected
-The system consume in total with the bulb connected 0.5 A

+what i need :
-The relay to switch on every time i switch on the bulb
-The relay to switch off every time i switch off the bulb
How i can make the circuit work with this system ?

Reply
Godfrey says:
May 4, 2020 at 12:33 am

Hello sir pliz help me build a1500watts inverter,I have no idea on how to make one, pliz show me the simplest circuit

Reply
Swagatam says:
May 4, 2020 at 9:57 am

Hello Godfrey, you can select any inverter circuit presented in this website and replace the MOSFETs with two parallel IRF540 for each channel. For battery use a 24 V 300 Ah battery, make sure to operate the oscillator circuit through a 7812 IC, and replace the transformer with a 24-0-24v, 70 amp transformer

Reply
Nikhil says:
September 10, 2019 at 1:52 pm

Hi,
I think for battery-powered applications relays are not a good choice, because of high coil current when energized. Can you suggest a good efficient replacement?. My considerations are p-channel power MOSFET or solid-state relays.
Thanks
Nikhil

Reply
Swagatam says:
September 10, 2019 at 4:19 pm

Hi, a relay is much better since it will allow the inverter to work with 100% battery power. The coil consumption will be negligible, may be 1 or 2% of the total inverter consumption. A MOSFET or SSR will dissipate energy causing the inverter to work with lower efficiency.

Reply
Nikhil says:
September 14, 2019 at 5:46 pm

Thank you, sir, for the reply.
I have one more doubt.
There is a chance for a slight increase in the voltage of a battery when a load is disconnected from the battery. Due to this, there is a chance for the relay to switch on again if the no-load battery voltage is above cut-off voltage. So a couple of switchings will occur before a stable state is reached.
Is this possible ?.
if possible, then how to solve this?.

Thanks & regards,
Nikhil

Reply
Swagatam says:
September 14, 2019 at 7:21 pm

Thanks Nikhil, The circuit is not voltage dependent, it’s current dependent. Voltage fluctuations will not affect the relay circuit, its the load current that will affect the circuit.

Reply
Apurva deepak says:
December 18, 2018 at 8:47 am

Because there has no center tape transformer will be used for output supply

Reply
Swagatam says:
December 18, 2018 at 9:09 am

You can try this:

https://www.homemade-circuits.com/2014/01/simplest-full-bridge-inverter-circuit.html

This is the only recommended design

Reply
Engr bashir says:
August 21, 2018 at 5:38 pm

ok Sir i will let u now when i am done

Reply
Engr bashir says:
August 21, 2018 at 2:44 pm

CORRECTIONS
Rx=0.2/0.4(400mA) =0.5ohm

hence 0.2x5A=1watt

therefore Rx=0.5 ohm 1 watt
did i do it correct??

Reply
Swagatam says:
August 21, 2018 at 4:28 pm

yes that looks OK to me, use a wirewound type resistor preferably.

Reply
Engr bashir says:
August 21, 2018 at 1:28 pm

That mean 0.5x5A=2.5 watt, therefore =0.5ohm 2.5watt resistor?? OR

0.5x 10A=5 watt, therefore =0.5ohm 2 watt resistor??

Reply
Swagatam says:
August 21, 2018 at 1:57 pm

It is not 0.5V it is 0.2 or 0.3V, please check again….

Reply
Engr bashir says:
August 21, 2018 at 11:23 am

ok sir as i did calculate it here

0.2/0.2=1ohm resisor,
0.2x.0.2=0.04 watt
That mean my resistor current must be 0.04watt am i correct???

Reply
Swagatam says:
August 21, 2018 at 11:26 am

it should be:

Rx = 0.2/0.4 (400 mAmps) = 0.5 ohms

wattage = 0.2 ohms x inverter maximum current.

inverter maximum current could be 5 amps or 10 amps as per inverter wattage

Reply
Engr bashir says:
August 21, 2018 at 10:45 am

GOOD MORNING SIR, i hv made this circuit today but the problem is that the Rx resistor is burning why?? it is 1 ohm 1/4w Check the image here

https://mobile.facebook.com/photo.php?fbid=1835553799874433&id=100002594924040&set=p.1835553799874433&source=47&ref=opera_speed_dial_freefb&__tn__=R

Reply
Swagatam says:
August 21, 2018 at 11:09 am

The formula for wattage will be: voltage drop across the resistor multiplied by the maximum current rating from the inverter battery.

Here the voltage across the resistor is supposed to be 0.2 or 0.3V, so multiply this by the maximum current draw of the inverter…..that will give you the wattage of the resistor.

Reply
Engr bashir says:
August 19, 2018 at 7:40 pm

thank u sir

Reply
Engr Bashir says:
August 19, 2018 at 1:29 pm

sir if i got you right that mean if my threshold is 400mA that mean i should calculate the Rx like this:- 0.2/0.2=1ohm resisor,
0.2x.0.2=0.04 watt

Reply
Swagatam says:
August 19, 2018 at 6:16 pm

It should be Rx = 0.2/0.4 = 0.5 ohms, in this case if the load is consuming below 400mA, the relay will switch OFF the inverter

Reply
Swapnil says:
January 21, 2018 at 4:35 pm

Sir
I need to construct the circuit to store combined electricity from solar and piezoelectric in battery and this battery will be used for inverter input .
It can be possible sir?

Reply
Swagatam says:
January 21, 2018 at 6:43 pm

Swapnil, how much voltage and current are you getting from your piezo source???

Reply
Techie says:
November 16, 2017 at 1:25 am

Doesn’t make sense. Even if the inverter is off you are losing the power at Rx resister

Reply
Swagatam says:
November 16, 2017 at 6:38 am

“losing power at Rx?” How? if the relay is switched OFF how will the inverter consume power??

Reply
Rick says:
May 14, 2017 at 10:42 pm

Hello Swagatam,

Everything is 100% clear now!

Thanks a ton for your time and dedication to explain the formula in detail.

Very much appreciated!

Success and regards,
Rick

Reply
Swagatam says:
May 15, 2017 at 5:13 am

You are most welcome Rick!!

Reply
Swagatam says:
May 14, 2017 at 12:57 pm

sorry, the answer should be 0.02 watts

…however 0.1 amps cannot be considered for calculating the Rx wattage, because 0.1 is the minimum current value, we would want it to be multiplied with the max current limit, which could be say for example 2 amps.

so Rx wattage for this example would be 0.2 x 2 = 0.4 watts

Reply
Swagatam says:
May 14, 2017 at 12:52 pm

for example let's assume the current threshold to be 100mA
T3/T4 triggering potential to be 0.2V, the Rx will be

0.2/0.1 = 2 ohm

wattage will be 0.2 x 0.1 = 0.04 watts

Reply
Swagatam says:
May 14, 2017 at 12:49 pm

Hi Rick,

the formula for calculating RX is T3/T4 minimum triggering level divided by the desired current threshold, and the wattage will be the desired current threshold multiplied by the triggering level.
I hope you got the relationship

Reply
Rick says:
May 14, 2017 at 5:30 am

Hi Swagatam,
Trying my luck again…
Ohms value calculation of Rx is clear, but what about Watts?

Thanks for your help,
Rick

Reply
Swagatam says:
May 14, 2017 at 1:29 pm

Hi Rick, I have clarified it in the above comment….

Reply
Gilligan says:
December 19, 2016 at 2:20 pm

Thank you for your reply. Do you sell parts? If not, do you have a parts list?

Reply
Swagatam says:
December 20, 2016 at 4:26 am

sorry I don't sell parts
the parts are already specified in the diagram, please click to enlarge it, and copy down the numbers as mentioned in the diagram…all the parts are standard type and does not need any consideration.

Reply
Gilligan says:
December 18, 2016 at 5:43 pm

Hi, I came across this post and the concept of your circuit is exactly what I am looking for. I have a 4k 110v AC inverter powered by 4 6v batteries wired in series for 12v. The inverter has a power saver mode built in (25 watts) but it will sense and turn on my 110v AC refrigerator. However, when I open the door, the light bulb is enough to trigger the inverter to power on. Also, the power sensor pulses every 3 seconds which I'm afraid might damage the compressor. So my question is, is the load in your circuit adjustable and how would I do that to sense a low load. Thank you in advance for your reply.

Reply
Swagatam says:
December 19, 2016 at 2:48 am

Hi, the resistor Rx value can be altered as per the required specifications, and the inverter can be enabled to switched ON or OFF at any desired load conditions. Higher values will allow the inverter to operate with higher loads only and vice versa,

Reply
Bady Badru says:
January 15, 2016 at 7:17 am

hellow sir i have this 60watts inverter what will be the value of Rx at full load and how can i obtain this minimum load current?

Reply
Swagatam says:
January 16, 2016 at 6:21 am

hello Bady, you can use the same value that's indicated in the diagram.

Reply
View Older Comments

Need Help? Please Leave a Comment! We value your input—Kindly keep it relevant to the above topic! Cancel reply

Your email address will not be published. Required fields are marked *

Primary Sidebar

circuit simulator image



Subscribe to get New Circuits in your Email



Categories

  • Arduino Projects (93)
  • Audio and Amplifier Projects (133)
  • Automation Projects (17)
  • Automobile Electronics (101)
  • Battery Charger Circuits (85)
  • Datasheets and Components (109)
  • Electronics Theory (149)
  • Energy from Magnets (27)
  • Games and Sports Projects (11)
  • Grid and 3-Phase (20)
  • Health related Projects (27)
  • Home Electrical Circuits (13)
  • Indicator Circuits (16)
  • Inverter Circuits (95)
  • Lamps and Lights (159)
  • Meters and Testers (71)
  • Mini Projects (28)
  • Motor Controller (68)
  • Oscillator Circuits (28)
  • Pets and Pests (15)
  • Power Supply Circuits (91)
  • Remote Control Circuits (50)
  • Renewable Energy (12)
  • Security and Alarm (64)
  • Sensors and Detectors (106)
  • SMPS and Converters (34)
  • Solar Controller Circuits (60)
  • Temperature Controllers (43)
  • Timer and Delay Relay (49)
  • Voltage Control and Protection (42)
  • Water Controller (36)
  • Wireless Circuits (30)





Other Links

  • Privacy Policy
  • Cookie Policy
  • Disclaimer
  • Copyright
  • Videos
  • Sitemap



People also Search

555 Circuits | 741 Circuits | LM324 Circuits | LM338 Circuits | 4017 Circuits | Ultrasonic Projects | SMPS Projects | Christmas Projects | MOSFETs | Radio Circuits | Laser Circuits | PIR Projects |

Social Profiles

  • Twitter
  • YouTube
  • Instagram
  • Pinterest
  • My Facebook-Page
  • Stack Exchange
  • Linkedin



Recent Comments

  • Swagatam on Arduino 2-Step Programmable Timer Circuit
  • Swagatam on Simple Buck-Boost Converter Circuits Explained
  • Swagatam on IC IR2111 H-Bridge MOSFET, IGBT Driver IC: Full Datasheet, Circuit Diagram
  • Swagatam on Electronic Circuit Projects, Tutorials, and Practical Engineering Solutions
  • Kadir on Simple 3 Phase Inverter Circuit

© 2026 · Swagatam Innovations