• Skip to main content
  • Skip to primary sidebar

Homemade Circuit Projects

Need circuit help? Post them in the comments! I've answered over 50,000!

Blog | Categories | About | Contact | Calculators-online
You are here: Home / Water Controller / Municipal Water Supply Sensor Controller Circuit

DIY Circuits | Learn Basics | Arduino Coding




Municipal Water Supply Sensor Controller Circuit

Last Updated on August 1, 2021 by Swagatam 104 Comments

In this post I have explained a simple water sensor with pump starter circuit for switching a pump motor during municipal water supply periods. The idea was requested by Mr. Hitesh Thapa.

Technical Specifications

Is it possible to make a automatic water pump starter which turns On only when the city supply line has water flowing.

Here is the scenario.

- City Supply Line opens only for 1 hour anytime during 6AM - 10AM or rarely sometimes in the evening depending on the water guy.

- We need to keep a watch during these times and keep the main tap open to see if the water has come.

- Once the water has come, we turn on the water pump attached to the main supply line to pump water into our underground water tank.

Could this be automated, like we install some sensor between the water pump and the main supply line that detects water and turns on the motor only when the supply is in full flow?

I have made the water level indicator at home from watching some videos online and it works fine for the overhead tank at home but this one seems to be tough nut to crack :).

Any help is highly appropriated.

Thanks,
Hitesh Thappa

Circuit Diagram

Parts List

  • Resistor 1k, 1/4 watt, 5% CFR = 1 no
  • Capacitor 10uF/25V Electrolytic = 1 no
  • Transistor TIP122 = 1no
  • Relay 12V/30 Amp/ SPDT = 1no
  • Diode 1N4007 = 1no
  • Stainless steel metal for the probes
  • 220 V AC to 12 V DC adapter = 1no

The Design

The circuit design of the proposed municipal water sensor with pump starter is very simple as may be witnessed in the shown diagram.

A Darlington TIP 122 transistor becomes the main active sensing device in the circuit. The device being a Darlington is very sensitive and thus becomes specifically suited to the application.

Its base and the positive DC are together clamped as probes across the water pipe mouth where the incoming utility water is intended to be sensed.

In absence of water the probes stay separated with air gap which renders a very high resistance across the probes which in turn keeps the transistor/relay stage switched off.

The 10uF capacitor at the base of the transistor ensures that the transistor does not get rattled or disturbed by external noises trying to make way through the sensor wires.

When utility water supply initiates, the pipe mouth begins throwing water into the adjoining tank, the speed of the water through pipe brushes across the probes creating a relatively low resistance across it.

This low resistance allows the positive DC to reach the base of the BJT triggering it into conduction...the transistor now conducts and switches ON the relay, the relay contacts shift position and switch ON the connected pump.

Upgrading the above municipal water sensor into an overhead tank overflow cut off circuit

The discussed circuit in the above section can be appropriately enhanced with an additional feature which will enable the circuit to sense an overhead tank full situation and switch OFF the relay along with the pump motor. The upgraded circuit design can be viewed  below:

Parts List

  • Resistor 1k, 1/4 watt, 5% CFR = 2 no
  • Capacitor 10uF/25V Electrolytic = 1 no
  • Capacitor 0.22uF PPC = 1no
  • Transistor TIP122 = 1no
  • Transistor BC547 = 2nos
  • Relay 12V/30 Amp/ SPDT = 1no
  • Diode 1N4007 = 1no
  • Stainless steel metal for the probes
  • 220 V AC to 12 V DC adapter = 1no

You'll also like:

  • Two Pipe Water Pump Valve Controller Circuit
  • SMS based Water notification schematicSMS Based Water Supply Alert System
  • capacitive fluid meter circuit compressedCapacitive Fluid Meter Circuit for Sealed Tanks
  • water level controller circuit using a float switchFloat Switch Controlled Water Level Controller Circuit

Filed Under: Water Controller Tagged With: Controller, Municipal, Sensor, Supply, Water

About Swagatam

I am an electronics engineer and doing practical hands-on work from more than 15 years now. Building real circuits, testing them and also making PCB layouts by myself. I really love doing all these things like inventing something new, designing electronics and also helping other people like hobby guys who want to make their own cool circuits at home.

And that is the main reason why I started this website homemade-circuits.com, to share different types of circuit ideas..

If you are having any kind of doubt or question related to circuits then just write down your question in the comment box below, I am like always checking, so I guarantee I will reply you for sure!

Previous Post: « Make this Insect Wing Signal Detector Circuit
Next Post: How to Make a Solar Panel Optimizer Circuit »

Reader Interactions

Comments

Deepak says:
October 2, 2018 at 8:13 pm

Thanks sir,
But I have one another problem.
Relay on without water in pipe line.
I put two probes across the water pipe with 1 pair of wire. 1 wire has dc voltege of 5.35 volt which comes from this circuit and the pararrel wire which is connected to bais of transistor also has dc voltage of 4.80 volt so how is it posible? And there is no water in the municipal pipe line even relay on !!! And there is 2 cm distance between two probe and also no continuity in wire while no water in pipe line

Reply
Swagatam says:
October 2, 2018 at 8:24 pm

Hi Deepak, it could mean either your transistor is faulty or its ground connection is broken. Change the transistor and check again. Also preferably connect the base wire through a diode to eliminate confusions.

Reply
Deepak says:
August 30, 2018 at 10:46 pm

Hello sir,
As it used 10uf 25 v capacitor in the base of transistor after the resister 1k. wht will happen when capacitor is charged and no water in pipe line than capacitor produce voltage to base of transistor without resister so it will not harm the transistor ?
As we know base of transistor need less than 0.7 v.

Reply
Swagatam says:
August 31, 2018 at 7:50 am

Hello Deepak, the charge stored in the capacitor will be restricted to a level which is perfectly safe for the transistor base. In fact the voltage level inside the capacitor will be restricted to 0.6V or 0.7V, because the forward voltage drop of most BJTs is restricted to this value therefore the capacitor can charge only upto this limit, so nothing to worry..

Reply
Imtiyaz says:
November 17, 2017 at 10:32 am

Hi Swagatam,
The circuit is working fine. Request you to suggest a suitable modified circuit for eliminating the problem of pump frequently switching on off frequently during the starting few minutes of water supply. I wish once the pump is started should not go off for a couple of minutes even if the sensor are sensing water and air in sequence until the supply is stable.
Hope I am clear.
Thanks in advance.

Reply
Swagatam says:
November 17, 2017 at 10:45 am

Hi Imtiyaz, I am glad it is working for you!

To solve this you can add a 470uF/25V capacitor across the relay coil, this will make sure that the relay does not stutter during the initial fluctuating water supply conditions.

Reply
Imtiyaz says:
November 22, 2017 at 11:19 am

The shuttering still persist, without resolving continuous practical application is not possible.
As I am a mechanical engineer, request you to forward a complete circuit with discussed modification and introduction of selector switch for auto and manual selection. It would be more asthetic if led indicators are also introduced.
My e-mail id is
imtiyaz_ur@yahoo.co.in
Thank you

Reply
Swagatam says:
November 22, 2017 at 2:02 pm

Hi, did you connect the capacitor across the relay coil? Even after you connect it if the water supply is too much fluctuating with large delays between ON and OFF then the relay will stutter,and cannot be solved with the above simple circuit.

In that case you will have to build a IC 555 monostable circuit and use it.

build the circuit which is shown in the following article

https://www.homemade-circuits.com/intruder-position-indicator-security/

remove the piezo, and connect the two wires with the water pipe probes.

remove the LED, resistor, and replace it with a relay, make sure to connect a diode across the relay coil.

The 1M pot will need to be correctly adjusted such that the stuttering just stops.

Reply
Imtiyaz says:
December 1, 2017 at 10:20 am

Thanks for the guidance,
All the 3 parts are working
A)Water sensing to start pump
B)Time delay to stop shuttering
C)Overflow pump stopping

Now one small problem, when incoming water stopped#pump goes off
But a slight residue water in the pipe touches the sensor the pump is restarted, how can this issue be tackled?

Reply
Swagatam says:
December 1, 2017 at 10:24 am

That’s great! I am glad it’s serving the purpose for you.

To solve the present issue, You will have to position the sensor in such a way that the water touches the sensor only when there’s some force in the water, otherwise without any force the residual water should be unable to come in contact with the sensor points.

Reply
Ashish Gautam says:
June 25, 2017 at 6:32 am

Is it not possible to use 12v AC instead of 12v DC ? A transformer could be used to convert 220v AC into 12v AC ?

Reply
Swagatam says:
June 28, 2017 at 8:49 am

you ca use the relay which is shown in the following article

https://www.homemade-circuits.com/2012/01/how-to-understand-and-use-relay-in.html

Reply
Swagatam says:
June 26, 2017 at 8:35 am

You can replace the TIP122 by manually making a Dalington using a 2N2222 and TIP31
A relay will work only with DC, not with AC unless its rectified

I have designed an anti-corrosion related circuit below, you can check it out:

https://www.homemade-circuits.com/2017/06/anti-corrosion-probes-for-water-level.html

Reply
Ashish Gautam says:
June 25, 2017 at 4:46 pm

Complex in what way ? Also, I am not able to find the Tip122 Darlington transistor, is there any substitute for it ? Does relay work in both AC and DC or is there different type of relay for different current ? And will 12v relay work for this circuit ?
Many thanks for the reply.

Reply
Swagatam says:
June 25, 2017 at 12:12 pm

It is possible, but the circuit could be come a little complex…

Reply
hemanth hearts says:
May 27, 2017 at 2:54 pm

Hello I want ready ckt is available in any where

Reply
Swagatam says:
May 28, 2017 at 7:12 am

sorry, there's no readymade unit available from here..

Reply
john kg says:
April 29, 2017 at 9:41 am

thank you sir for ur kind advice one more query how much should be the gap need to maintain between the sensor probes and voltage to supply ( our supply pipe is 1.5 inch dia )

john

Reply
Swagatam says:
April 29, 2017 at 2:49 pm

the distance could be around 1cm, but make sure that it is built in such a way that water does not clog between this gap when water supply has stopped.

Reply
john kg says:
April 29, 2017 at 2:59 am

good day sir
is it possible to use probe be made off aluminium ( easily avaliable from home utensil) instead of brass ( not easily availiable in my place )

john

Reply
Swagatam says:
April 29, 2017 at 8:05 am

good day john,

you can try the same circuit which is explained above, for indication you can connect an LED in series with the base of the transistor.

for the sensor aluminum will work but aluminum may be also prone to oxidation. instead you can use copper and tin it with a thick layer of solder…the solder should be of the highest grade with a tin/lead ratio of 60/40…or better.

Reply
john kg says:
April 29, 2017 at 2:55 am

good day sir

i need acircuit which detects water flow and giving indication of same when pump starting to fill the overhead tank . we are using pvc pipes and what kind of snsor probs can be used instead of brass for effctive response

john

Reply
Unknown says:
April 27, 2017 at 7:10 am

I want to buy a 'READY TO USE' Controller
which can Switch – On the pump, when it detects
water flow from the City's supply and when
the same stops, it Switch – Off the pump. Has
any company incorporate this circuit design in
their Controller device ? And if so, please list
the name and contact info. Thanks

Sudhir
Gurgaon HR

April 27, 2017

Note: Needless to say, the controller, should have
other features, like Switch Off the pump, when tank
gets filled

Reply
Ganesh Budukale says:
December 22, 2016 at 11:49 am

Respected sir,
as per this circuit diagram and instruction build the same but i dint get result , would u can mail me with details .progressofganesh@gmail.com

Reply
Swagatam says:
December 22, 2016 at 4:41 pm

…you can also try reducing the 10uF to 1uF for better response

Reply
Swagatam says:
December 22, 2016 at 4:39 pm

Ganesh, the concept explained is very straightforward and should work without fail, you might have done something incorrect in your design…

you can confirm the results using a cup of water and immerse the sensor points inside it to check whether the relay clicks or not…

Reply
Meet Patel says:
December 5, 2016 at 4:54 am

Great. Now this would become Dual functionality embedded in one circuit only. Thanks a lot.

Reply
Swagatam says:
December 5, 2016 at 12:21 pm

My pleasure!!

Reply
Meet Patel says:
December 2, 2016 at 3:30 am

Hello sir, have you thought on that new concept which I requested earlier?

Reply
Swagatam says:
December 3, 2016 at 6:28 am

….I have updated the new design at the bottom of the article.

Reply
Swagatam says:
December 3, 2016 at 5:27 am

Meet, due to lack of time I could not do it, will try to update it soon…

Reply
Meet Patel says:
November 25, 2016 at 4:02 pm

No problem. Thanks.

Reply
Meet Patel says:
November 25, 2016 at 10:18 am

How should I make water level controller system in this same circuit? So that after filling tank the motor will automatically turn-off, please guide me.

Reply
Swagatam says:
November 25, 2016 at 2:09 pm

I'll try to upadte the idea in the above article soon…

Reply
Meet Patel says:
November 25, 2016 at 8:48 am

sorry I made a mistake. There is a single phase motor, not three phase motor. So i got solution. Thanks.

Reply
Swagatam says:
November 25, 2016 at 2:09 pm

OK, in that case you can use a regular SPDT relay with 30 amp contacts.

Reply
Meet Patel says:
November 25, 2016 at 6:06 am

As you said I purchased 3 pole relay of PLA company (3C/O MPC 12D-5) having 11 pin encircled. It has 3 pole so on 3 common , 3 N/C and 3 N/O. Now how should I make a connection of 3 phase motor with this relay? please help me out.

Reply
Meet Patel says:
November 23, 2016 at 3:41 pm

Thanks a lot. Now I got the whole scenario.

Reply
Meet Patel says:
November 22, 2016 at 7:34 am

should I use single channel relay on 3 phase motor or else double channel relay is suitable for the same?

Reply
Swagatam says:
November 23, 2016 at 10:47 am

relays can conduct AC/DC both, but in 3 phase there are 3 lines therefore 3 contacts would be required, a single contact relay cannot work

Reply
Meet Patel says:
November 23, 2016 at 3:31 am

Ok. Thanks. Because single channel relay can conduct only DC supply.

Reply
Swagatam says:
November 23, 2016 at 2:10 am

for 3 phase motor you will require a TPTT relay or 3-pole relay with heavy duty contacts

Reply
Meet Patel says:
November 21, 2016 at 3:27 am

ok. thank you so much.

Reply
Meet Patel says:
November 18, 2016 at 9:50 am

Hey.. Appreciated your project.
I have one doubt.
What type of sensor probes being used?

Reply
Swagatam says:
November 18, 2016 at 10:40 am

thanks meet, you can use brass terminals with solder plating as the probes.

Reply
Faisal Pasha says:
June 28, 2016 at 3:56 pm

Finally I got circuit diagram from Google images, Mr. Swagatam Majumdar can you tell me how much voltages is required to run this circuit because i'm mechanical student I've not enough knowledge about electronics circuit.

Reply
Swagatam says:
June 29, 2016 at 12:16 pm

Faisal, you can operate it with 12V… if the relay is also 12V rated, or any voltage that matches the relay coil voltage

Reply
Faisal Pasha says:
June 28, 2016 at 10:39 am

Dear Swagatam Majumdar,
The project (Municipal water supply sensor, pump controller circuit) circuit diagram doesn't show on your site. please send me circuit diagram at email id: faisalpasha9090@gmail.com
thanks!

Reply
Swagatam says:
June 28, 2016 at 11:36 am

Dear Faisal, it could be your ISP problem, please read this:

https://www.linkedin.com/pulse/20140620140349-53089235-blogspot-down-in-pakistan

Reply
Zafar Ahmed Abbasi says:
May 25, 2016 at 6:39 pm

very helpful thank you

Reply
Nick Hayes says:
June 1, 2015 at 6:04 am

How much DC voltage do I need for this?

Reply
Swagatam says:
June 2, 2015 at 12:03 pm

you can refer to the following article, the relay explanation along with its specs are provided here

https://www.homemade-circuits.com/2012/01/how-to-understand-and-use-relay-in.html

Reply
Swagatam says:
June 1, 2015 at 11:37 am

will depend upon the relay voltage spec used, if it's 12v then the supply can also be 12V and so on.

Reply
Advance Hi Tech says:
October 5, 2014 at 5:08 pm

Required support to repair the electronic circuit

Reply
Back to Newest

Need Help? Please Leave a Comment! We value your input—Kindly keep it relevant to the above topic! Cancel reply

Your email address will not be published. Required fields are marked *

Primary Sidebar

circuit simulator image



Subscribe to get New Circuits in your Email



Categories

  • Arduino Projects (93)
  • Audio and Amplifier Projects (133)
  • Automation Projects (17)
  • Automobile Electronics (101)
  • Battery Charger Circuits (85)
  • Datasheets and Components (109)
  • Electronics Theory (149)
  • Energy from Magnets (27)
  • Games and Sports Projects (11)
  • Grid and 3-Phase (20)
  • Health related Projects (27)
  • Home Electrical Circuits (13)
  • Indicator Circuits (16)
  • Inverter Circuits (95)
  • Lamps and Lights (159)
  • Meters and Testers (71)
  • Mini Projects (28)
  • Motor Controller (68)
  • Oscillator Circuits (28)
  • Pets and Pests (15)
  • Power Supply Circuits (91)
  • Remote Control Circuits (50)
  • Renewable Energy (12)
  • Security and Alarm (64)
  • Sensors and Detectors (106)
  • SMPS and Converters (34)
  • Solar Controller Circuits (60)
  • Temperature Controllers (43)
  • Timer and Delay Relay (49)
  • Voltage Control and Protection (42)
  • Water Controller (36)
  • Wireless Circuits (30)





Other Links

  • Privacy Policy
  • Cookie Policy
  • Disclaimer
  • Copyright
  • Videos
  • Sitemap



People also Search

555 Circuits | 741 Circuits | LM324 Circuits | LM338 Circuits | 4017 Circuits | Ultrasonic Projects | SMPS Projects | Christmas Projects | MOSFETs | Radio Circuits | Laser Circuits | PIR Projects |

Social Profiles

  • Twitter
  • YouTube
  • Instagram
  • Pinterest
  • My Facebook-Page
  • Stack Exchange
  • Linkedin



Recent Comments

  • Swagatam on Arduino 2-Step Programmable Timer Circuit
  • Swagatam on Simple Buck-Boost Converter Circuits Explained
  • Swagatam on IC IR2111 H-Bridge MOSFET, IGBT Driver IC: Full Datasheet, Circuit Diagram
  • Swagatam on Electronic Circuit Projects, Tutorials, and Practical Engineering Solutions
  • Kadir on Simple 3 Phase Inverter Circuit

© 2026 · Swagatam Innovations